Air quality monitors · Parameters and sensor types, PM2.5 accuracy against reference monitors, US EPA sensor target values, communication outputs, power, enclosure and certification
An air quality monitor is an electronic instrument that draws in or samples air, measures pollutants such as particulate matter, carbon dioxide, volatile organic compounds and formaldehyde with a set of sensors, and reports or transmits the readings with temperature and humidity. Ask three things first: which parameters and ranges you need, what evidence shows the readings agree with reference monitors, and which outputs, power supply and mounting the installation requires.
Fixed indoor and outdoor multi-parameter air quality monitors built on low-cost sensors, for buildings, campuses and non-regulatory community monitoring. Standalone sensor modules, gas detection systems for safety alarms and regulatory reference (FRM/FEM) analysers are outside this page.
01
US EPA's report on PM2.5 air sensors (EPA/600/R-20/280, February 2021) covers ambient, outdoor, fixed-site, non-regulatory supplemental and informational monitoring. Its base test collocates at least three replicate sensors with FRM/FEM reference monitors for at least 30 days at each of two sites in different climate regions, and compares the data as 24-hour averages. [1]
Its base-testing target values are precision as standard deviation ≤ 5 µg/m³ or coefficient of variation ≤ 30%, slope 1.0 ± 0.35, intercept between −5 and +5 µg/m³, R² ≥ 0.70, and RMSE ≤ 7 µg/m³ or NRMSE ≤ 30%; for enhanced laboratory testing it recommends reporting results without target values. It also suggests at least one test day with a 24-hour average of 25 µg/m³ or more. [1]
EPA states that the protocols are voluntary, that testers receive no certification, and that it does not track or evaluate claims to meet the targets; it encourages testers to publish their data and graphs. Data from sensors should not be used for regulatory compliance unless the instruments meet the applicable federal requirements. [2]
Editorial note: ask the supplier for a collocation report against a reference monitor in conditions like yours, with the averaging time, the metrics above and the correction applied, rather than a single accuracy percentage.
Give the supplier the site (indoor, outdoor, duct), parameters and ranges, required accuracy evidence, averaging and reporting interval, output protocol (Modbus, BACnet, Ethernet, Wi-Fi, cellular), power supply, mounting, enclosure rating, display or indicator needs, data platform, building-certification programme if any, and quantities.
02
Tongdy's MSD-18 commercial indoor monitor lists up to seven parameters: PM2.5 and PM10 by laser light scattering (0–500 and 0–800 µg/m³, PM2.5 accuracy 10% of reading from 0–300 µg/m³ at 25 °C and 10–60 %RH), CO2 by NDIR (0–5,000 ppm, ±50 ppm + 3% of reading), TVOC by metal-oxide sensor, formaldehyde by electrochemical sensor, and temperature and humidity. [3]
The same listing gives RS485 (Modbus RTU or BACnet MS/TP), RJ45 Ethernet or 2.4 GHz Wi-Fi outputs, 12–28 V DC, 18–27 V AC or 100–240 V AC supply, average consumption of 1.9 W at 24 V, 0–50 °C operation, a PC/ABS IP20 housing, CE, FCC and ICES marks, and a constant-flow fan for the particle sensor. [3]
Editorial note: the accuracy statements above are the maker's laboratory conditions; ask how readings are compensated for temperature and humidity, what replacement or recalibration interval each sensor needs, and whether the data platform flags drift.
03
Suppliers linked to this page list air quality monitors; each card links to the page reviewed.
Listings include commercial indoor multi-sensor monitors, in-duct monitors and outdoor monitors with solar supply alongside CO2 and temperature controllers.
04
South Coast AQMD's AQ-SPEC programme tests sensors in the field against federal reference or equivalent instruments at an air monitoring station, and in an environmental chamber, and publishes R² and mean absolute error (MAE) for each pollutant a device reports. Its field data come from a 30- to 60-day period at one station on 5-minute or 1-hour averages, with no calibration by agency staff, and the agency states that the results cannot be duplicated at a different location, season or time period. [4]
Two field results from the table show why one device needs one result per pollutant. R² near 1 reflects a near-perfect correlation with the reference and 0 a complete lack of correlation; a larger MAE means a larger error. [4]
Editorial note: AQ-SPEC field R² uses 5-minute or 1-hour averages, while the EPA base target of R² ≥ 0.70 uses 24-hour averages, so ask which averaging time a quoted R² uses before comparing it with that target. [4] [1]
05
This is a functional reference built from the sources cited; it is not one maker's design.
| Part | Role | Fix in the order |
|---|---|---|
| Particle sensor | Laser scattering PM2.5/PM10. [3] | Range, accuracy, collocation data. |
| Gas sensors | NDIR CO2, metal-oxide TVOC, electrochemical HCHO. [3] | Ranges, accuracy, life. |
| Temperature and humidity sensor | Compensation and comfort data. [3] | Accuracy. |
| Fan or pump | Constant air flow to sensors. [3] | Flow control, service life. |
| Processor and firmware | Compensation and averaging. [1] [3] | Algorithm, update method. |
| Communication module | Data output. [3] | Protocol, network. |
| Enclosure | Mounting and protection. [3] | Material, IP rating. |
06
An air quality monitor quotation needs values for your site. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Measurement Range for PM2.5 (µg/m³) | 0–500 µg/m³ in one indoor monitor. [3] | Range and resolution. |
| Measurement Accuracy (%) | EPA base targets: slope 1.0 ± 0.35, R² ≥ 0.70, RMSE ≤ 7 µg/m³. [1] | Collocation report. |
| Response Time (seconds) | Reporting and averaging interval. | Sampling and output interval. |
| Operating Temperature (°C) | 0–50 °C in one indoor monitor. [3] | Range for your site. |
| Power Supply (V DC / mAh) | 12–28 V DC, 18–27 V AC or 100–240 V AC in one model. [3] | Supply and consumption. |
| Measurement Range for PM10 (μg/m³) | 0–800 µg/m³ in one model. [3] | Range. |
| Measurement Range for CO2 (ppm) | 0–5,000 ppm NDIR in one model. [3] | Range and accuracy. |
| Measurement Range for TVOC (ppb) | One model reports 0–3.5 mg/m³. [3] | Range, unit and calibration gas. |
| Measurement Range for Humidity (%RH) | 0–99 %RH in one model. [3] | Range and accuracy. |
| Measurement Range for Temperature (°C) | −20 to 60 °C sensor range in one model. [3] | Range and accuracy. |
| IP Rating | IP20 for one indoor model. [3] | Rating for indoor or outdoor use. |
| Weight (g) | Mounting. | Weight. |
| Dimensions (W×H×D) (mm) | Mounting. | Drawing. |
07
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Site: [indoor; outdoor; duct; mounting] Parameters: [PM2.5; PM10; CO2; TVOC; HCHO; T/RH; ranges] Evidence: [collocation report; averaging; metrics] Outputs: [Modbus; BACnet; Ethernet; Wi-Fi; cellular] Power: [supply; consumption] Supply: [enclosure; certification; quantity]
These companies list air quality monitors.
Lists commercial indoor multi-sensor air quality monitors with PM2.5, PM10, CO2, TVOC, HCHO, temperature and humidity.
Product scope checked 2026-10-11
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
US EPA recommends base-testing targets of R² ≥ 0.70, slope 1.0 ± 0.35, intercept within ±5 µg/m³ and RMSE ≤ 7 µg/m³ or NRMSE ≤ 30% on 24-hour averages. [1]
No. EPA says the protocols are voluntary, give no certification and that it does not evaluate claims to meet the targets. [2]
One commercial indoor monitor uses laser scattering for particles, NDIR for CO2, metal-oxide for TVOC and electrochemical for formaldehyde. [3]
Not necessarily. In South Coast AQMD's AQ-SPEC field tests one unit reached R² 0.83 to 0.89 for PM2.5 but 0.34 to 0.37 for PM10, so ask for results for each pollutant. [4]
Sources checked 2026-10-11. The US EPA report sets voluntary test targets for outdoor PM2.5 sensors; Tongdy describes its own product. Performance for your site must come from collocation data and the supplier's specifications.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.