An electronic device that converts, amplifies, filters, and isolates sensor signals for compatibility with control systems.
Technical details and manufacturing context for Industrial Signal Conditioner
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Input Signal TypeRequired | 4-20, 0-10, RTD, TC type | Type of input signal accepted (e.g., thermocouple type J/K, RTD, 4-20mA, 0-10V, mV) |
| Output Signal TypeRequired | 4-20, 0-10, RS-485 type | Type of output signal produced (e.g., 4-20mA, 0-10V, 0-5V, digital protocol) |
| AccuracyRequired | ±0.05 % of full scale | Maximum deviation from true value as percentage of full scale |
| Isolation VoltageRequired | 1500 V | Maximum voltage that can be sustained between input, output, and power circuits |
| Operating Temperature RangeRequired | -40–85 °C | Ambient temperature range for proper operation |
| Power SupplyRequired | 24 ±10% V DC | Required DC power supply voltage |
| Response Time | ≤10 ms | Time required for output to reach 90% of final value after step input change |
| Input Impedance | ≥1 MΩ | High impedance for minimal loading |
| Output Load Resistance | 0–600 Ω | Maximum load for current output |
| Temperature Coefficient | ≤0.01 % FS/°C | Stability over temperature |
| Humidity Range | 0–95 % RH | Non-condensing |
| Protection Rating | IP65 | Dust-tight and protected against water jetsIEC 60529 |
| Weight | ≤0.5 kg | Compact and lightweight |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
Commonly used trade names and technical identifiers for Industrial Signal Conditioner.
| pressure: | 0 to 1000 psi |
| other spec: | Input signal range: 0-10V, 4-20mA, RTD, thermocouple; Output signal: 0-10V, 4-20mA; Isolation: 1500V AC |
| temperature: | -40°C to 85°C |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
7 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
It accepts various input signal types including 4-20mA current loops, 0-10V voltage, RTD (resistance temperature detector) signals, and thermocouple signals (e.g., type J or K). The specific input type must be configured according to the sensor used.
It provides standardized output signals such as 4-20mA current loops, 0-10V voltage, and RS-485 digital communication. The output type is selected based on the control system requirements.
The isolation voltage is 1500V, which means the device can withstand up to 1500V between input, output, and power circuits without breakdown. This helps prevent ground loops and protects against voltage spikes.
The operating temperature range is -40 to 85°C. The device is designed to function reliably within this ambient temperature range, but always verify the specific model's ratings with the manufacturer.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.