Strukturierte Komponentendaten · 2026

Interlayer Insulation

Insulating layer between magnetic core laminations in medium voltage current transformers to reduce eddy current losses and improve efficiency.

Technische Definition und Einsatzkontext
Ein typisches Interlayer Insulation wird in Elektrogeräteherstellung nach Material, Toleranz, Montage- und Anwendungskompatibilität sowie Ausfallrisiko bewertet.

Interlayer insulation is a critical component in medium voltage current transformer core assemblies, consisting of thin insulating material layers inserted between stacked magnetic steel laminations. Its primary function is to electrically isolate individual laminations, thereby minimizing eddy current circulation within the core during alternating current operation. This insulation reduces core heating, improves transformer efficiency by lowering no-load losses, and enhances magnetic performance by maintaining proper flux distribution. The component must withstand thermal cycling, mechanical compression forces, and maintain dielectric strength throughout the transformer's operational lifespan.

Komponentenspezifikationen

Definition
Interlayer insulation is a critical component in medium voltage current transformer core assemblies, consisting of thin insulating material layers inserted between stacked magnetic steel laminations. Its primary function is to electrically isolate individual laminations, thereby minimizing eddy current circulation within the core during alternating current operation. This insulation reduces core heating, improves transformer efficiency by lowering no-load losses, and enhances magnetic performance by maintaining proper flux distribution. The component must withstand thermal cycling, mechanical compression forces, and maintain dielectric strength throughout the transformer's operational lifespan.
Funktionsprinzip
Works by creating electrical barriers between conductive magnetic steel laminations in transformer cores. When alternating magnetic flux passes through the core, it induces circulating currents (eddy currents) within the conductive laminations. The insulating layers interrupt these current paths, forcing eddy currents to circulate within individual laminations only, dramatically reducing their magnitude and associated I²R heating losses. This principle follows Faraday's law of electromagnetic induction and utilizes high-resistance dielectric materials to block inter-lamination current flow while allowing magnetic flux to pass through with minimal reluctance.
Materialien
Typically composed of: 1. Electrical grade paper (KraftNomex) with thickness 0.05-0.15mm2. Polyester film (PETMylar) 0.025-0.1mm thick3. Composite materials (paper-film-paper combinations)4. Epoxy or phenolic resin coatings for enhanced bonding and moisture resistance. Materials must have dielectric strength >5kV/mmthermal class B-F (130-155°C)low moisture absorption (<1%)and good mechanical strength under compression.
Thickness
0.05-0.15 mm
Thermal Class
B to F (130-155°C)
Compression Set
<10% after 1000h at rated pressure
Tensile Strength
>50 MPa
Dielectric Strength
>5 kV/mm
Moisture Absorption
<1%
Surface Resistivity
>10^12 ohm/sq
Normen
IEC 60076IEEE C57.13ASTM D202ISO 9001

Branchentaxonomie & Aliasse

Gebräuchliche Handelsnamen, technische Kennungen und Suchbegriffe für Interlayer Insulation.

Uebergeordnete Produkte

Diese Komponente wird in den folgenden Industrieprodukten eingesetzt.

FMEA · Fehleranalyse

Ursache → Fehlermodus → Engineering-Massnahme

Thermal aging and oxidation->Reduced dielectric strength leading to inter-lamination short circuits->Use thermal class appropriate materials, implement temperature monitoring, regular insulation resistance testing
Mechanical stress during core clamping->Insulation tearing or compression beyond recovery limits->Control clamping force, use compression-resistant materials, implement proper assembly procedures
Moisture ingress->Decreased surface resistivity and potential tracking->Use moisture-resistant coatings, maintain dry storage conditions, implement vacuum drying during transformer assembly

Industrielles Ökosystem und technische Bewertung

0
Insulation degradation from thermal cycling
1
Moisture absorption reducing dielectric strength
2
Mechanical damage during core assembly
3
Delamination under compression forces
4
Chemical contamination from transformer oil

Konformität und Prüfung

tolerance
Thickness tolerance ±0.01mm, dielectric strength tolerance +0/-10%, dimensional stability within ±0.5% after thermal cycling
test method
Dielectric strength per IEC 60243, insulation resistance per IEC 60093, thermal aging per IEC 60216, compression testing per ASTM D395

Hersteller für diese Komponente

Relevante Herstellerprofile aus der CNFX-Komponentenfähigkeitstabelle.

Die Herstellerliste dient der Vorrecherche und Einordnung von Fertigungskapazitäten. Sie ist keine Zertifizierung, kein Ranking und keine Transaktionsgarantie.

Beispielhafte Bewertungskriterien aus Einkaufsprozessen

Keine Kundenbewertung und keine Echtzeitdaten. Die Werte zeigen typische Prüfkriterien in RFQ- und Lieferantenbewertungsprozessen.

Technische Dokumentation
4/5
Fertigungsfähigkeit
4/5
Prüfbarkeit
5/5
Lieferantentransparenz
3/5

Die Kriterien dienen als Orientierung für technische Einkaufsprüfungen. Konkrete Kunden, Länder, Bewertungsdaten oder Live-Nachfragen werden nur angezeigt, wenn entsprechende belastbare Daten vorliegen.

Verwandte Komponenten

Haeufige Fragen

Why is interlayer insulation necessary in transformer cores?

Interlayer insulation prevents eddy current circulation between laminations, reducing core heating and energy losses by up to 90% compared to uninsulated cores.

What happens if interlayer insulation fails?

Insulation failure allows eddy currents to circulate between laminations, causing excessive core heating, increased no-load losses, potential thermal damage to adjacent components, and reduced transformer efficiency.

How is interlayer insulation tested for quality?

Quality testing includes dielectric strength tests (hipot), insulation resistance measurements, thermal aging tests, compression set evaluation, and microscopic inspection for uniformity and defects.

Kann ich Hersteller direkt kontaktieren?

CNFX ist ein offenes Verzeichnis, keine Handelsplattform und kein Beschaffungsagent. Herstellerprofile und Formulare helfen bei der Vorbereitung des direkten Kontakts.

CNFX Industrial Component Index · Elektrogeräteherstellung

Datenbasis

CNFX-Herstellerprofile, technische Klassifikation, öffentlich verfügbare Produktinformationen und fortlaufende Plausibilitätsprüfung.

Vorläufige technische Einordnung
Diese Seite dient der strukturierten Vorbereitung von Recherche, RFQ und Lieferantenbewertung. Sie ersetzt keine Lieferantenqualifizierung, keine Normenprüfung und keine technische Freigabe durch den Käufer.

Beschaffungsinformationen anfragen für Interlayer Insulation

Informationen zu Einsatzbereich, Spezifikationsgrenzen, Lieferantentypen und RFQ-Vorbereitung anfragen.

Vielen Dank. Ihre Anfrage wurde gesendet.
Vielen Dank. Ihre Anfrage wurde empfangen.

Fertigung für Interlayer Insulation?

Herstellerprofile mit passender Bearbeitungs- oder Montagefähigkeit vergleichen.

Herstellerprofil anlegen Kontakt
Vorherige Komponente
射频干扰垫片
Naechste Komponente
层间绝缘
URN:CNFX:ME:UNIT:INTERLAYER_INSULATION