Isolation barrier for intrinsically safe circuits: the galvanically isolated barrier used where a zener barrier and its safety earth are not wanted

DIN-rail isolated barriers in the safe area feeding Ex ia field circuits · isolated barrier or zener barrier · entity values Uo, Io, Po, Co, Lo and Um · insulation between hazardous side, control side and supply

Every intrinsically safe loop needs a device in the safe area that limits how much voltage, current and power can reach the hazardous area if something goes wrong on the control side. That device is either a zener barrier, which shunts fault energy to a dedicated earth, or an isolating barrier, which separates the two sides galvanically. The "if required" in this product's name is the design decision: an isolated barrier is chosen where a barrier earth, blown fuses or earth loops are a problem. Buying one means matching its certified entity values to the field device and cable, and checking the insulation it gives between field, control and supply.

Galvanically isolated intrinsic-safety barriers (isolated barriers, IS isolators) mounted in the safe area or Zone 2 on DIN rail or backplane, for analog, digital, temperature and communication signals to Ex ia field devices, with their entity parameters and insulation ratings. Non-Ex DIN-rail signal conditioners and isolators are covered on the Industrial signal conditioner page; component opto-isolators on the Wide-creepage surface-mount opto-isolator page; non-Ex multi-channel optocoupler boards on the DIN-rail optocoupler isolation board page; road safety barriers and safety light curtains are different products.

CNFX editorial research · Sources checked October 19, 2026 · 3 sources

Isolation Barrier (if required) in a manufacturing environment
Representative product image. Confirm appearance and specifications with the manufacturer.

01

Isolating barrier or zener barrier: safety earth, fuses and earth faults

LGM Products' barrier selection guide states that every intrinsically safe circuit must be protected by a suitable IS barrier, and describes the two types. Zener barriers combine zener diodes, resistors and fuses; MTL700 series barriers must be replaced if the internal non-replaceable fuse blows, while the later 7700 series has electronic fuses; and the negative rail of the compatible zener barriers connects directly to earth, which can cause problems with control panels fitted with earth-fault monitoring. [3]

Galvanic isolating barriers, in the same guide, isolate the hazardous area from the safe area, are fully resettable and contain no fuses, and let the IS circuit be left floating or earthed at any one point, avoiding earth-loop faults that can occur with zener barriers. The guide says they cost more than zener barriers but give a simpler engineering solution, and that barriers of either type must be located in the safe area. [3]

Pepperl+Fuchs' KCD2-STC-Ex1, a 1-channel isolated barrier that supplies 2-wire SMART transmitters, shows what the isolated type carries besides the barrier function: a 19–30 V DC supply over a power rail, a 4–20 mA output repeated to the control side to within ±0.1% in source mode at 20 °C, HART passed through, and SIL 2 to IEC 61508. [1]

State whether the plant uses a dedicated IS earth, whether the control panel has earth-fault monitoring, and how many loops are involved; those decide whether isolated barriers are required.

02

Uo, Io, Po, Co, Lo and Um: the certified values to match against the field device and cable

An isolated barrier's certificate data give the maximum output voltage, current and power at its hazardous-area terminals (Uo, Io, Po), the capacitance and inductance that may be connected to them (Co, Lo), and the highest voltage the safe-area side may see without losing intrinsic safety (Um). Two published examples:

Editorial calculation: in both examples the stated Po equals Uo × Io ÷ 4 (25.2 V × 100 mA ÷ 4 = 630 mW; 15 V × 8.5 mA ÷ 4 ≈ 31.9 mW). The KCD2-STC-Ex1's second terminal pair (3+, 4-) is listed with Uo 7.2 V, Io 100 mA and Po 25 mW, so the values to use depend on which terminals the field device is wired to. [1] [2]

Pinghe states its barrier is installed in the safe zone and can connect to intrinsically safe instruments in hazardous areas up to Zone 0, IIC, Zone 20 and IIIC. [2] P+F shows the field side in Zone 0, 1 or 2 and the barrier itself in Zone 2 or the safe area, with a separate Ex nA IIC T4 Gc marking for Zone 2 mounting. [1]

ValuePepperl+Fuchs KCD2-STC-Ex1 (terminals 1+, 2-)Beijing Pinghe PHD-11TC-11 (terminals 1-3-4)
Marking[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I [1][Ex ia Ga] IIC [Ex ia Da] IIIC [2]
Um250 V AC ("Um is no rated voltage") [1]250 V [2]
Uo25.2 V [1]15 V [2]
Io100 mA [1]8.5 mA [2]
Po630 mW [1]31.9 mW [2]
Co / LoNot listed in the data sheet reviewed0.41 µF / 100 mH [2]
Signal4–20 mA transmitter input with HART [1]RS-232 two-way, 1 in / 1 out [2]

Ask for the certificate number and the entity values for each terminal pair, and compare Uo, Io and Po against the field device's Ui, Ii and Pi, and Co and Lo against the device plus cable capacitance and inductance.

03

How strongly field, control and supply sides are separated

P+F rates the insulation between input, output and supply of the KCD2-STC-Ex1 as reinforced to EN 50178 at 300 V rms rated insulation voltage, and as safe electrical isolation to IEC/EN 60079-11 at 375 V peak between input and output and between input and supply. [1]

Pinghe gives dielectric strength for its PHD-11TC-11 as at least 3,000 V AC for one minute between the intrinsically safe and non-intrinsically safe sides and at least 1,500 V AC between the supply and the non-intrinsically safe terminals, insulation resistance of at least 100 MΩ between input, output and supply, operation from −20 to +60 °C, and EMC to IEC 61326-1 and IEC 61326-3-1. [2]

The two makers express the separation differently, one as rated insulation voltage and peak isolation voltage, the other as one-minute test voltages, so compare them on the same basis by asking each for the test voltage and duration between each pair of sides.

Specify the signal type and count, supply method (terminals or power rail), SIL requirement, ambient temperature in the cabinet and the hazardous-area classification of every field device.

04

What an isolated barrier enquiry should state

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Signal: [4–20 mA in/out; HART; digital; RTD/TC; RS-232/485]
Channels: [per module; total]
Field device: [Ui, Ii, Pi, Ci, Li; zone; gas/dust group]
Cable: [length; capacitance; inductance]
Mounting: [safe area or Zone 2; DIN rail or backplane; power rail]
Safety: [SIL; certificate scheme]
Environment: [cabinet temperature]

See manufacturer records Send an enquiry through CNFX

Isolated barrier makers

2 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.

Beijing Pinghe Entrepreneurship Technology Development Co., Ltd.
Manufacturing site to be confirmed for the order

Lists T and H series isolated safety barriers for analog, digital, temperature, frequency and communication signals, with Ex ia certification data.

Product scope checked 2026-10-19

Current product source ↗

Isolated safety barriers listed · profile compiled by CNFX from public sources
HollySys
Manufacturing site to be confirmed for the order

Lists AM5000EX, AM2000EX and AM3000EX isolated safety barriers for hazardous areas, for 4–20 mA, HART and other signals.

Product scope checked 2026-10-19

Current product source ↗

Isolated safety barriers listed · profile compiled by CNFX from public sources

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

Why use an isolated barrier instead of a zener barrier?

LGM Products notes isolated barriers need no fuses, are resettable and let the IS circuit float or be earthed at one point, while zener barriers tie the negative rail to earth. [3]

What does Um mean on a barrier?

The highest voltage the safe-area side may see without losing intrinsic safety; P+F lists 250 V AC and notes Um is not a rated voltage. [1]

How much power can an isolated barrier deliver into the hazardous area?

It depends on the model: P+F's KCD2-STC-Ex1 lists Po 630 mW on its transmitter terminals; Pinghe's PHD-11TC-11 lists 31.9 mW. [1] [2]

Sources and what still needs a direct check

Sources checked 2026-10-19. Pepperl+Fuchs and Beijing Pinghe barrier data sheets for entity and insulation values, and LGM Products' guide to choosing between zener and isolating barriers.

  1. Pepperl+Fuchs — KCD2-STC-Ex1 SMART transmitter power supply, technical data (2018) ↗ Manufacturer data sheet Return to text ↑
  2. Beijing Pinghe — PHD-11TC-11 isolated safety barrier at detection side, product page ↗ Manufacturer product page Return to text ↑
  3. LGM Products — A simple guide to barrier selection ↗ Distributor technical guide Return to text ↑

Still to check yourself

  • Match Uo, Io, Po to the device.
  • Check Co and Lo against the cable.
  • Compare isolation on one basis.
Buyer enquiry

Request manufacturing insight for Isolation Barrier (if required)

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Isolation Barrier (if required)?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Wire Tensioning System
Last Product
Get QuotesChat