Editorial Technical Reference

Glycol-coolant reservoir column level sight gauge

Machinery coolant reservoirs · direct visual liquid level

A reservoir sight column makes the coolant level visible outside the tank wall. Selection starts with the liquid-contact materials and the level interval that must be seen at the installed position.

Externally mounted tubular sight columns for direct visual reading of glycol-based coolant in machinery reservoirs, with fluid-compatible transparent tube and seals. Level gauge (4114) covers the wider magnetic and vessel glass-gauge category; Coolant tank/reservoir (4128) covers the sump itself. Pressure-vessel inspection windows, electronic level transmitters and float switches are separate products.

CNFX editorial research · Sources checked October 16, 2026 · 3 sources

01

The liquid-contact tube and the outer shield are different parts

ELESA’s HCK-GL brochure specifies a Pyrex liquid-contact tube and a removable polycarbonate impact shield. Its HCK-GL-SST execution uses FKM seals; the HCK-GL seal is described simply as rubber. Confirm the seal grade for the coolant formulation. [1]

LDI’s G613 is a different construction: a rigid nylon sight tube with aluminium end blocks and Buna N seals. Its official caution explicitly excludes recommended use with ethylene glycol antifreeze and polyglycols. A visually similar oil sight gauge therefore needs its own fluid-compatibility check before substitution into a coolant tank. [2]

02

Mounting-centre distance is not the visible liquid span

In the HCK-GL dimension table, HCK.127-GL-M12 has mounting-centre distance f = 127 mm and visible length l2 = 71 mm. Position the required level interval within that visible length, rather than treating the mounting spacing as the readable range. [1]

03

Resolve the execution before using the brochure’s temperature statement

ELESA’s model page gives continuous limits of 100°C for HCK-GL and 130°C for HCK-GL-SST with oil, water or glycol solutions. Its summary illustration instead states 130°C continuous, peaks at 160°C and pressure of 5/6 bar without naming the execution. Confirm the applicable execution and pressure–temperature conditions with ELESA; retain the distinction between continuous and peak service. [1]

The model page also reports laboratory tests at 150/160°C for “many hours” with pressures of 5/6 bar. These are reported laboratory observations, separate from the model-specific continuous limits. [1]

04

Order an electrical low-level function separately from the window

ELESA+Ganter’s range guide distinguishes visual indicators from executions with a MIN-level electrical sensor, and from float-based indirect indicators. State whether the requirement is an operator’s visual check or an electrical low-level signal, then obtain a compatible execution for the coolant. The range guide is a family selector, not approval to interchange its wetted materials. [3]

Provide the coolant name, glycol type and concentration, additives, continuous and peak temperature, tank pressure, required visible interval, mounting-hole drawing, wall thickness and inspection access. Identify any required low-level contact and its electrical interface separately.

05

Define the coolant and the level interval at the tank wall

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Fluid: [glycol; concentration; additives]
Conditions: [continuous/peak temperature; pressure]
Reading: [required visible interval; access]
Mounting: [hole centres; threads; wall; seals]
Signal: [visual only or electrical low-level function]

See manufacturer records Send an enquiry through CNFX

Coolant reservoir sight-gauge suppliers

Manufacturer profiles associated with Sight Glass/Level Indicator.

Sourcing Sight Glass/Level Indicator from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

Can any oil sight gauge be used with glycol coolant?

No. LDI’s G613 caution specifically advises against ethylene glycol antifreeze and polyglycols. Confirm the exact tube and seal materials for the liquid. [2]

Are mounting centres and visible length the same dimension?

The HCK-GL table lists them separately as f and l2. [1]

Does a visible coolant level provide an electrical alarm?

The ELESA+Ganter range guide identifies MIN-level sensor executions separately. Specify an electrical contact if the machine needs a low-level signal. [3]

Sources and what still needs a direct check

Sources checked 2026-10-16. The HCK-GL brochure supplies model-specific construction and dimensions. LDI supplies a material-related exclusion for its nylon alternative; the ELESA+Ganter range guide separates visual and electrical executions.

  1. ELESA+Ganter — HCK-GL column level indicators brochure, p.3 model data and p.4 summary illustration ↗ Manufacturer technical brochure Return to text ↑
  2. LDI Industries — G613 rigid nylon sight gauge, materials and fluid exclusions ↗ Manufacturer product and caution Return to text ↑
  3. ELESA+Ganter — Column level indicators range guide, visual and electrical executions ↗ Manufacturer family-selection guide Return to text ↑

Still to check yourself

  • Confirm compatibility with the actual coolant.
  • Match the visible span and mounting drawing.
  • Resolve model-specific continuous and peak limits.
  • Specify any electrical low-level function.
Buyer enquiry

Request manufacturing insight for Sight Glass/Level Indicator

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Sight Glass/Level Indicator?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Z-axis Ram/Spindle
Last Product
Get QuotesChat