This page explains how Calibration Sensor is classified within Computer, Electronic and Optical Product Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
A precision electronic component that measures and adjusts the accuracy of medical monitoring equipment.
Technical details and manufacturing context for Calibration Sensor
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Measurement Range | 0–100 kPa | Covers typical medical gas pressures |
| Accuracy | ±0.5 % FS | Includes nonlinearity, hysteresis, repeatabilityIEC 60770 |
| Output Signal | 4–20 mA | Two-wire loop powered |
| Supply Voltage | 12–36 V DC | Reverse polarity protected |
| Operating Temperature | -40–85 °C | Compensated range -20–60 °CIEC 60068-2-1 |
| Storage Temperature | -40–125 °C | Non-operatingIEC 60068-2-2 |
| Ingress Protection | IP65–IP67 | Dust-tight and protected against water jetsIEC 60529 |
| Overpressure Limit | 200 kPa | No performance change after overpressure |
| Burst Pressure | 500 kPa | Housing integrity maintained |
| Response Time | <10 ms | 10–90% step change |
| Insulation Resistance | >100 MΩ | At 500 V DCIEC 60255-5 |
| Weight | 150–200 g | Without cable |
| Material | 316L | Wetted parts in stainless steelASTM A276 |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
Commonly used trade names and technical identifiers for Calibration Sensor.
This component is essential for the following industrial systems and equipment:
| pressure: | 0 to 100 psi |
| other spec: | Humidity: 0-95% RH non-condensing, Accuracy: ±0.1% of reading |
| temperature: | -20°C to +85°C |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
1 company lists this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The measurement range is 0–100 kPa, which covers typical medical gas pressures. This is a reference range; confirm the exact range for your specific model with the manufacturer.
The accuracy is ±0.5% FS, including nonlinearity, hysteresis, and repeatability, per IEC 60770. This is a reference value; verify the actual accuracy for your model.
The operating temperature range is -40 to 85 °C, with a compensated range of -20 to 60 °C, per IEC 60068-2-1. Storage temperature is -40 to 125 °C per IEC 60068-2-2.
The sensor has an IP65–IP67 rating per IEC 60529, meaning it is dust-tight and protected against water jets. This is a reference; check the specific model's rating.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.