This page explains how Alarm Output Relay is classified within Electrical Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
An electrical relay that activates external alarm devices or systems when triggered by safety monitoring signals.
Technical details and manufacturing context for Alarm Output Relay
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Contact Rating | 10–30 A | Maximum switching current at 250 V AC |
| Coil Voltage | 12–24 V DC | Standard control voltage range |
| Coil Power Consumption | 0.9–1.8 W | At nominal coil voltage |
| Contact Resistance | ≤50 mΩ | Initial value at 6 V DC, 1 A |
| Insulation Resistance | ≥1000 MΩ | Between coil and contacts at 500 V DC |
| Dielectric Strength | 1500–2500 V AC | Between coil and contacts for 1 minute |
| Operating Temperature | -40–70 °C | Ambient temperature range |
| Mechanical Life | ≥10^7 operations | No load switching |
| Electrical Life | ≥10^5 operations | At rated resistive load |
| Response Time | ≤20 ms | From coil energization to contact closure |
| Release Time | ≤20 ms | From coil de-energization to contact opening |
| Degree of Protection | IP54–IP65 | Depends on enclosureIEC 60529 |
| Weight | 30–80 g | Typical for relay module |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
| current: | Up to 10A resistive load |
| voltage: | 5-250V AC/DC |
| temperature: | -40°C to +85°C |
| switching speed: | ≤10ms response time |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
A practical evidence checklist for RFQ preparation and supplier evaluation.
Compare the published product scope and source details, then include your specifications and quantity in an enquiry.
Manufacturer profiles associated with Alarm Output Relay.
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
It acts as an interface between a safety monitoring system and external alarm devices. When a hazardous condition is detected, the relay changes its contact state to activate alarms, indicators, or shutdown systems.
Typical reference ranges include contact rating of 10–30 A at 250 V AC, coil voltage of 12–24 V DC, and coil power consumption of 0.9–1.8 W. Always verify actual values for the specific model.
The relay receives a low-voltage control signal, energizing the coil and moving the armature. This changes the contact state within a response time of ≤20 ms, activating the external alarm circuit.
The operating temperature range is -40 to 70 °C, and the degree of protection is IP54–IP65 per IEC 60529. Confirm suitability for your specific environment with the manufacturer.
This component is essential for the following industrial systems and equipment:
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Compare manufacturer profiles with relevant product and process capability.