INDUSTRY COMPONENT

Calibrated Scale

A calibrated scale is a precision measurement component used in depth adjustment gauges for accurate dimensional verification in industrial applications.

Component Specifications

Definition
A calibrated scale is a graduated measurement component integrated into depth adjustment gauges, featuring precisely marked increments (typically in millimeters or inches) that have been verified against traceable standards. It provides a visual reference for setting and verifying depth measurements in machining, assembly, and quality control processes, ensuring dimensional accuracy and repeatability.
Working Principle
The calibrated scale operates on the principle of linear measurement through visual alignment. Graduated markings on the scale correspond to specific distance units, allowing operators to set or verify depth by aligning a reference point (such as a pointer or indicator) with the appropriate marking. Calibration ensures that each marking accurately represents its designated measurement, compensating for manufacturing tolerances and environmental factors.
Materials
Stainless steel (AISI 304 or 316 for corrosion resistance), hardened tool steel, or anodized aluminum with laser-etched or engraved markings. Surface may include wear-resistant coatings like titanium nitride.
Technical Parameters
ParameterTypical rangeNotes & selection driver
Accuracy±0.05 mm
Scale Length160 mm
Mounting TypeIntegrated or modular attachment
Measurement Range0-150 mm
Graduation Interval0.5 mm or 0.02 inches
Environmental RatingIP54 (dust and splash resistant)

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Standards
DIN 862

Parent Products

This component is used in the following industrial products

Engineering Analysis

Risks & Mitigation
  • Measurement inaccuracy due to wear or contamination
  • Misalignment during installation
  • Calibration drift over time
FMEA Triads
Trigger: Accumulation of debris on scale markings
Failure: Reduced measurement accuracy and readability
Mitigation: Regular cleaning with approved solvents and protective covers when not in use
Trigger: Mechanical shock or impact
Failure: Scale deformation or marking damage
Mitigation: Proper handling procedures and shock-absorbing mounting systems

Industrial Ecosystem

Compatible With

Typical Suppliers & Equivalents

Compliance & Inspection

Tolerance
±0.05 mm over full measurement range
Test Method
Laser interferometry or coordinate measuring machine verification against NIST-traceable standards

Procurement Evaluation Criteria

A practical evidence checklist for RFQ preparation and supplier evaluation.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Manufacturers of Calibrated Scale

Manufacturer profiles associated with Calibrated Scale.

Sourcing Calibrated Scale from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Related Components

Chrome Plating
Hard chrome plating is an electroplating process that deposits a layer of chromium onto metal surfaces to enhance wear resistance, corrosion protection, and reduce friction for hydraulic cylinder piston rods.
Upper Tool (Punch)
Upper Tool (Punch) is the active forming component in metal plate bending machines that applies precise downward force to create bends in sheet metal.
Main Frame
The main frame is the primary structural component of a hydraulic press, providing rigidity and stability to withstand high compressive forces during metal forming operations.
Shaft Bearing
Precision component supporting rotating shafts in vibration motors to reduce friction and maintain alignment.

Frequently Asked Questions

How often should a calibrated scale be recalibrated?

Recalibration intervals depend on usage frequency and environmental conditions, typically ranging from 6 to 12 months for industrial applications, following ISO 17025 guidelines.

Can calibrated scales be used in harsh environments?

Yes, scales made from stainless steel with protective coatings can withstand moderate industrial environments, but should be protected from extreme temperatures, chemicals, and abrasive contaminants.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records. See the editorial policy.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.

Request Manufacturing Insight for Calibrated Scale

Thank you. Your request has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at contact@cnfx.com.
Yoke Bracket