INDUSTRY COMPONENT

Status Indicator (LED)

LED status indicator for digital output modules in industrial automation systems.

Component Specifications

Definition
A solid-state light-emitting diode (LED) component integrated into digital output modules to provide visual status indication of output channel states, such as active/inactive, fault conditions, or communication status, in industrial control systems.
Working Principle
Operates by converting electrical signals from the digital output module's control circuit into visible light through electroluminescence in a semiconductor diode, with brightness and color indicating specific operational states.
Materials
Semiconductor materials (typically gallium arsenide phosphide or indium gallium nitride), epoxy resin encapsulation, copper alloy leads, and aluminum or ceramic substrate.
Technical Parameters
ParameterTypical rangeNotes & selection driver
ColorRed/Green/Yellow/Blue
Current10-20mA
Voltage2.0-3.3V DC
Lifespan50,000-100,000 hours
Brightness100-500 mcd
Response Time<100 ns
Viewing Angle120-160 degrees
Operating Temperature-40°C to +85°C

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Standards
ISO 7000, IEC 60073, DIN EN 60073

Parent Products

This component is used in the following industrial products

Engineering Analysis

Risks & Mitigation
  • Overcurrent damage
  • Heat degradation
  • Moisture ingress
  • Vibration failure
  • Color misinterpretation
FMEA Triads
Trigger: Excessive forward current
Failure: LED burnout or premature dimming
Mitigation: Implement current-limiting resistors, use constant current drivers, and follow manufacturer's specifications
Trigger: Environmental contamination
Failure: Reduced light output or complete failure
Mitigation: Use IP-rated enclosures, apply conformal coating, and maintain clean operating environments

Industrial Ecosystem

Compatible With

Typical Suppliers & Equivalents

Compliance & Inspection

Tolerance
±5% current regulation, ±10% brightness variation
Test Method
IEC 60068-2 environmental testing, MIL-STD-202 vibration testing, photometric measurement per CIE standards

Procurement Evaluation Criteria

A practical evidence checklist for RFQ preparation and supplier evaluation.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Manufacturers of Status Indicator (LED)

Manufacturer profiles associated with Status Indicator (LED).

Sourcing Status Indicator (LED) from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Share this page

Related Components

Marking Strip
A durable marking strip used for terminal identification in motor terminal blocks to ensure proper electrical connections and safety compliance.
Gland Body
A gland body is the main housing component of an aluminum cable gland that provides mechanical protection and environmental sealing for electrical cables entering enclosures.
Current Sense Resistor
A precision resistor used to measure current flow in electrical circuits by converting current to a measurable voltage drop.
Conductor Terminal
A conductor terminal is a critical electrical component designed to securely connect and terminate conductors in high-voltage insulating bushings, ensuring reliable electrical transmission and insulation integrity.

Frequently Asked Questions

What do different LED colors indicate on digital output modules?

Red typically indicates active output or fault conditions, green shows normal operation or ready status, yellow/amber warns of pending actions or marginal conditions, and blue may indicate communication activity or special modes.

How do I troubleshoot a non-functioning status LED?

Check power supply to the module, verify output channel configuration, test with known working signals, inspect for physical damage, and measure voltage at LED terminals. Replace if internal driver circuit or LED itself has failed.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records. See the editorial policy.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.

Request Manufacturing Insight for Status Indicator (LED)

Thank you. Your request has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].
Yoke
Get QuotesChat