INDUSTRY COMPONENT

Tube (for peristaltic pumps)

Flexible tubing for peristaltic pumps that transfers fluids via compression cycles without contamination.

Component Specifications

Definition
A specialized elastomeric tube designed for peristaltic pumps, where rotating rollers or shoes compress the tube to create a moving occlusion that propels fluid through the system. This design ensures the fluid only contacts the tube interior, making it ideal for sterile, abrasive, or corrosive applications where contamination must be avoided.
Working Principle
Operates through cyclic compression by pump rollers, which sequentially squeeze the tube to create a peristaltic wave that pushes fluid forward while maintaining complete separation between the fluid and pump mechanics.
Materials
Typically made from silicone, thermoplastic elastomers (TPE), fluoropolymers (like PTFE), or natural rubber, selected based on chemical compatibility, flexibility, and durability requirements.
Technical Parameters
ParameterTypical rangeNotes & selection driver
Inner Diameter1-50 mm
Shore Hardness40-80 A
Wall Thickness1-10 mm
Pressure RatingUp to 100 psi
Temperature Range-50°C to 200°C

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Standards
ISO 13485, DIN 11864

Parent Products

This component is used in the following industrial products

Engineering Analysis

Risks & Mitigation
  • Tube fatigue and cracking
  • Chemical incompatibility
  • Reduced flow rate from wear
  • Contamination if material degrades
FMEA Triads
Trigger: Material fatigue from repeated compression
Failure: Tube rupture or leakage
Mitigation: Regular inspection and scheduled replacement based on usage hours
Trigger: Chemical attack from incompatible fluids
Failure: Tube degradation and contamination
Mitigation: Use chemically resistant materials and verify compatibility charts

Industrial Ecosystem

Compatible With

Typical Suppliers & Equivalents

Compliance & Inspection

Tolerance
±0.5 mm on inner diameter, ±10% on wall thickness
Test Method
ASTM D638 for tensile strength, ISO 10993 for biocompatibility

Procurement Evaluation Criteria

A practical evidence checklist for RFQ preparation and supplier evaluation.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Manufacturers of Tube (for peristaltic pumps)

Manufacturer profiles associated with Tube (for peristaltic pumps).

Sourcing Tube (for peristaltic pumps) from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Share this page

Related Components

Mounting Interface
Precision mounting interface connecting punch tips to pharmaceutical tablet press machines for accurate tablet production.
Chrome Plating
Hard chrome plating is an electroplating process that deposits a layer of chromium onto metal surfaces to enhance wear resistance, corrosion protection, and reduce friction for hydraulic cylinder piston rods.
Upper Tool (Punch)
Upper Tool (Punch) is the active forming component in metal plate bending machines that applies precise downward force to create bends in sheet metal.
Main Frame
The main frame is the primary structural component of a hydraulic press, providing rigidity and stability to withstand high compressive forces during metal forming operations.

Frequently Asked Questions

How often should peristaltic pump tubes be replaced?

Replacement intervals depend on material, fluid type, and operating conditions; typically every 200-1000 hours to prevent fatigue failure.

Can these tubes handle abrasive fluids?

Yes, with materials like reinforced silicone or specialized polymers, but wear rates increase, requiring more frequent replacement.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records. See the editorial policy.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.

Request Manufacturing Insight for Tube (for peristaltic pumps)

Thank you. Your request has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].
Yoke Bracket
Get QuotesChat