X-ray Tube Mount

This page explains how X-ray Tube Mount is classified within Machinery and Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.

Technical Definition & Core Assembly

A structural component that securely positions and supports the X-ray tube within the gantry assembly of medical imaging equipment.

Representative product image. Confirm appearance and specifications with the manufacturer.

Product Specifications

Technical details and manufacturing context for X-ray Tube Mount

Definition
The X-ray Tube Mount is a critical mechanical component within the gantry of CT scanners, X-ray machines, and other medical imaging systems. It provides precise, stable mounting for the X-ray tube, ensuring proper alignment with detectors and maintaining consistent focal spot positioning during rotational movements. This mount must withstand mechanical stresses, thermal expansion from tube operation, and maintain vibration isolation to ensure image quality. The mount mechanically interfaces with the X-ray tube housing using precision brackets or clamps, often incorporating thermal expansion compensation mechanisms and vibration dampening materials. It transfers the tube's weight and operational forces to the gantry structure while maintaining precise angular and positional relationships required for accurate beam projection. Materials on file include aluminum alloy, stainless steel, and carbon fiber composite. Key parameters include material grade (e.g., 6061-T6 aluminum, 304 stainless steel), mounting hole diameter (6.5–12.5 mm), mounting hole spacing (50–200 mm), flatness (0.05–0.1 mm per ISO 1101), surface roughness (Ra 1.6–3.2 µm per ISO 4287), operating temperature (-10 to 50 °C), relative humidity (10–90% non-condensing), IP rating (IP54–IP65 per IEC 60529), load capacity (50–150 kg), weight (1.5–8 kg), vibration resistance (5–500 Hz per IEC 60068-2-6), and tensile strength (310–520 MPa per ASTM B221/ASTM A240). These values are directory reference ranges; actual specifications must be confirmed with the legal manufacturer or supplier for the specific model and application. The mount is designed for integration into gantry systems, and its selection depends on tube weight, gantry geometry, and operational environment. Verification of material grades, dimensional tolerances, and compliance with applicable standards is essential during procurement. Maintenance signals include visible wear, loosening of fasteners, or degradation of vibration dampening. Failure boundaries include exceeding load capacity, operating outside temperature/humidity limits, or exposure to corrosive environments beyond material ratings.
Working Principle
The mount mechanically interfaces with the X-ray tube housing using precision brackets or clamps, often incorporating thermal expansion compensation mechanisms and vibration dampening materials. It transfers the tube's weight and operational forces to the gantry structure while maintaining precise angular and positional relationships required for accurate beam projection. The design must accommodate thermal expansion from tube operation and isolate vibrations to preserve image quality. Selection inputs include tube weight, gantry interface pattern, and environmental conditions. Verification questions should address material grade confirmation, dimensional tolerances, and compliance with standards such as ISO 1101 and IEC 60529. Maintenance signals include loosening of fasteners or excessive vibration. Failure boundaries include exceeding load capacity or operating outside specified temperature and humidity ranges.
Common Materials
Aluminum alloy, Stainless steel, Carbon fiber composite
Technical Parameters
ParameterTypical rangeNotes & selection driver
Material Grade6061-T6 / 304Aluminum for weight reduction; stainless for corrosion resistance.ASTM B221 / ASTM A240
Mounting Hole Diameter6.5–12.5 mmMatches standard bolt sizes.
Mounting Hole Spacing50–200 mmCompatible with gantry interface patterns.
Flatness0.05–0.1 mmEnsures proper seating and alignment.ISO 1101
Surface RoughnessRa 1.6–3.2 µmCritical for sealing surfaces.ISO 4287
Operating Temperature-10–50 °COutside range may affect material properties.
Relative Humidity10–90 %Non-condensing.
IP RatingIP54–IP65Protects against dust and water jets.IEC 60529
Load Capacity50–150 kgMust support tube and associated hardware.
Weight1.5–8 kgAffects gantry balance and motor sizing.
Vibration Resistance5–500 HzWithstands operational vibration without loosening.IEC 60068-2-6
Tensile Strength310–520 MPaEnsures structural integrity under load.ASTM B221 / ASTM A240

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Components / BOM
  • Mounting Bracket Part
    Primary structural interface that directly contacts and secures the X-ray tube housing
    Material: Stainless steel
  • Vibration Isolator
    Dampens mechanical vibrations from tube operation to prevent image artifacts
    Material: Silicone rubber composite
  • Thermal Compensation Shim Part
    Compensates for differential thermal expansion between tube and mount materials
    Material: Copper alloy
  • Clamps Optional
    Clamp form of the mechanical interface to the tube housing.

Industry Taxonomies & Aliases

Commonly used trade names and technical identifiers for X-ray Tube Mount.

Applied To / Applications

This component is essential for the following industrial systems and equipment:

Industrial Ecosystem & Supply Chain Structure

Complementary Systems
Downstream Applications
Specialized Tooling

Application Fit & Sizing Matrix

Operational Limits
pressure: Atmospheric to 1.5 bar
other spec: Vibration tolerance: ≤0.5g RMS, 5-2000 Hz
temperature: -20°C to +80°C
Media Compatibility
✓ Medical-grade air environments ✓ Clean room conditions ✓ Non-corrosive gas atmospheres
Unsuitable: High-humidity or corrosive chemical environments
Sizing Data Required
  • X-ray tube weight and dimensions
  • Gantry mounting interface specifications
  • Required positional accuracy and stability tolerances

Reliability & Engineering Risk Analysis

Failure Mode & Root Cause
Thermal fatigue cracking
Cause: Repeated heating/cooling cycles from X-ray operation cause expansion/contraction stresses in tube mount materials, leading to crack initiation and propagation at stress concentrators like welds or bolt holes.
Electrical insulation breakdown
Cause: Degradation of insulating materials due to high-voltage stress, thermal aging, or contamination accumulation, resulting in arcing, short circuits, or ground faults that compromise tube performance and safety.
Maintenance Indicators
  • Audible arcing or buzzing sounds during operation, indicating electrical discharge or insulation issues
  • Visible discoloration, scorching, or carbon tracking on insulating surfaces around the mount, suggesting overheating or electrical faults
Engineering Tips
  • Implement strict thermal cycling management by minimizing unnecessary on/off cycles and using controlled warm-up/cool-down procedures to reduce thermal stress on mount components
  • Establish regular high-potential (hipot) testing and insulation resistance monitoring to detect early insulation degradation before catastrophic failure occurs

Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.

Compliance & Manufacturing Standards

Applicable Standards
IEC 60601-1:2005+AMD1:2012+AMD2:2020 - Medical electrical equipment safety ASTM E94/E94M-22 - Standard guide for radiologic examination

Quoted from the published standard.

Manufacturing Precision
  • Mounting surface flatness: ≤0.05mm
  • Bore concentricity: ≤0.02mm TIR
Quality Inspection
  • Leakage current test per IEC 60601-1
  • Dimensional verification with coordinate measuring machine (CMM)

Manufacturers of X-ray Tube Mount

Manufacturer profiles associated with X-ray Tube Mount.

Sourcing X-ray Tube Mount from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Supply Chain Compatible Machinery & Devices

Hydraulic Press

Industrial machine using hydraulic pressure to compress, form, or assemble materials

Explore Specs →
Heavy-Duty CNC Plasma Cutting Machine

The Heavy-Duty CNC Plasma Cutting Machine is a standalone industrial device designed for cutting conductive metals such as steel, stainless steel, aluminum, and copper alloys.

Explore Specs →
Automated Powder Coating System

Integrated industrial system for applying dry powder coatings to metal substrates.

Explore Specs →
Centrifugal Pump Impeller

The centrifugal pump impeller is a critical rotating component that converts mechanical energy from the motor into kinetic energy in fluid systems.

Explore Specs →

Frequently Asked Questions

What materials are used for the X-ray Tube Mount?

According to the directory, materials on file include aluminum alloy, stainless steel, and carbon fiber composite. Specific grades such as 6061-T6 aluminum and 304 stainless steel are listed as reference ranges. Always confirm the exact material with the manufacturer for your application.

What are the key dimensional parameters?

Key parameters include mounting hole diameter (6.5–12.5 mm), mounting hole spacing (50–200 mm), flatness (0.05–0.1 mm per ISO 1101), and surface roughness (Ra 1.6–3.2 µm per ISO 4287). These are reference ranges; verify with the supplier.

What environmental conditions can it withstand?

The directory lists operating temperature of -10 to 50 °C, relative humidity of 10–90% non-condensing, and IP rating of IP54–IP65 per IEC 60529. Confirm these limits with the manufacturer for your specific model.

How do I verify compliance with standards?

Standards referenced include ISO 1101 for flatness, ISO 4287 for surface roughness, IEC 60529 for IP rating, IEC 60068-2-6 for vibration resistance, and ASTM B221/ASTM A240 for material grades. These are procurement references; ensure the supplier provides documentation of compliance.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.
Buyer enquiry

Request manufacturing insight for X-ray Tube Mount

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What we don't claim
A listing is not an endorsement. Qualify every supplier and verify every figure yourself before ordering.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at contact@cnfx.com.

Need to Manufacture X-ray Tube Mount?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Z-axis Ram/Spindle
Last Product
Get QuotesChat