Sensor calibration circuit: the signal-conditioner IC that stores trim coefficients and corrects a bridge sensor's offset, span and temperature drift

Sensor electronics · Calibration-on-chip: front end, ADC, math core and coefficients in EEPROM or NVM that trim a bridge sensor at end of line

Inside a pressure transmitter, load cell or similar transducer, the raw sensing element is never accurate on its own: offset, span, temperature drift and nonlinearity vary part to part. The calibration circuit is the piece of electronics that removes them. It measures the element and a temperature, applies a correction whose coefficients were calculated for that individual sensor on a test rig, and keeps those coefficients in non-volatile memory for the life of the product. Buying one, the questions are how many coefficients it can hold, how many pressure and temperature points calibration needs, and how the stored trim is protected and checked.

Integrated calibration and compensation circuits for resistive bridge and similar sensors: analogue front end, ADC, digital correction core, coefficient memory, and the calibration interface and procedure used at end of line. Complete load-cell amplifier modules are covered on the Load-cell signal conditioner page and DIN-rail transmitters on the Industrial signal conditioner page; stand-alone converters on the ADC and DAC pages; and custom chip development on the Application-specific integrated circuits page.

CNFX editorial research · Sources checked October 17, 2026 · 3 sources

01

A polynomial in pressure and temperature, held in on-chip memory

TI's PGA302 data sheet writes the correction as a third-order polynomial in the digitised pressure P and temperature T: OUTPUT = (h0 + h1T + h2T² + h3T³) + (g0 + g1T + g2T² + g3T³)·P + (n0 + n1T + n2T² + n3T³)·P² + (m0 + m1T + m2T² + m3T³)·P³, after a digital gain and offset on each channel; the result is clamped to programmable limits and filtered by a second-order IIR filter. [2]

Editorial calculation: the four bracketed terms with four coefficients each make 16 TC and NL coefficients, plus a gain and offset per channel (a0, b0, a1, b1), so 20 values are calculated and written for each sensor. Counted from the PGA302 equations only. [2]

The same data sheet's text heading says the PGA300 family "implements a second order TC and NL correction", while its figure and equation show third order; check the order with the supplier for the exact part. [2]

Renesas' ZSSC3241 describes digital compensation of offset, sensitivity, temperature drift and nonlinearity by a math core with coefficients stored in reprogrammable non-volatile memory; its description calls this a 26-bit math core while the feature list says 24-bit main math core, and the main core performs auto-zero, span and first- and second-order temperature compensation, with a second 16-bit core correcting DAC gain and offset. [3]

PartSensor inputConversionCorrection and memoryOutputs
TI PGA305Bridge, 1–135 mV/V [1]24-bit ΣΔ signal and temperature ADCs; 14-bit DAC [1]Third-order offset, gain and nonlinearity TC; EEPROM for calibration and user data [1]Voltage, ratiometric, 4–20 mA; I²C and one-wire [1]
TI PGA302Resistive bridge; gain up to 200 V/V [2]16-bit ΣΔ ADC [2]3rd-order linearity algorithm; EEPROM with CRC byte [2]0–5 V ratiometric output; I²C and one-wire [2]
Renesas ZSSC3241Bridge, half-bridge, Pt100; 1–500 mV/V [3]ADC resolution 12, 16 or 24 bit; 16-bit DAC [3]Coefficients in NVM; 1st and 2nd order TC [3]0–1 V, 0–5 V, ratiometric, 4–20 mA; SPI, I²C, OWI [3]

02

End-of-line calibration: known points, a calibration master, then the write

Renesas sets out the ZSSC3241 procedure in steps: give each IC a unique identification in its customer-ID registers to index a database on the calibration PC; collect raw readings at known measurand values and temperatures; let the calibration master calculate the coefficients and program them into NVM. It warns that a calibration only fits the front-end setup used during it, so the front-end NVM registers must stay unchanged through calibration and afterwards. [3]

TI's PGA302 application example reports three pressure points at one temperature (3P1T): at 0.5, 2.5 and 4.5 V expected output it measured 0.503, 2.501 and 4.498 V, errors of 0.075, 0.025 and −0.05 %FSR, and it also ran 3P3T and 4P4T calibrations to show accuracy across −40 to 150 °C. [2]

Editorial check: with a 0.5–4.5 V span (4 V FSR), 0.003 V / 4 V = 0.075%, 0.001 / 4 = 0.025% and −0.002 / 4 = −0.05%, matching the table. [2]

On storage, the PGA302 reserves the last EEPROM byte for a CRC over all EEPROM data, calculated and validated whenever that byte is programmed and re-checkable on command; programming draws an extra 1.5 mA on VDD. Renesas recommends calibrating the DAC characteristic during IC calibration where absolute accuracy matters, since DAC offset and gain vary IC to IC. [2] [3]

Agree with the supplier the number of pressure and temperature points per sensor, the calibration interface and fixture, how the unique ID and raw data are logged, and how the coefficient memory is verified after writing.

03

Sensor, output and calibration-line details for the IC choice

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Sensor: [bridge type; sensitivity mV/V; excitation]
Output: [ratiometric or absolute voltage; 4–20 mA; digital]
Compensation: [order of TC and NL; temperature range]
Calibration: [pressure × temperature points; interface I²C/SPI/OWI]
Memory: [EEPROM or NVM; CRC or checksum; user data]
Supply: [voltage range; reverse protection]

See manufacturer records Send an enquiry through CNFX

Sensor signal-conditioner IC makers

Manufacturer profiles associated with Calibration circuit.

Sourcing Calibration circuit from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

How many calibration points does a bridge sensor need?

It depends on the correction order; TI reports 3-pressure, 1-temperature and also 3×3 and 4×4 calibrations for the PGA302. [2]

Where are the calibration coefficients kept?

In on-chip EEPROM (PGA302, PGA305) or reprogrammable NVM (ZSSC3241), written by the calibration master at end of line. [2] [1] [3]

Can the front-end settings be changed after calibration?

Renesas warns that a ZSSC3241 calibration only fits the setup used, so front-end registers must stay fixed. [3]

Sources and what still needs a direct check

Sources checked 2026-10-17. Two Texas Instruments data sheets (PGA305, PGA302) and Renesas' ZSSC3241 data sheet; where a data sheet contradicts itself both statements are given.

  1. Texas Instruments — PGA305 Signal Conditioner and Transmitter for Pressure Sensors (SBASB63, Aug 2024) ↗ Manufacturer data sheet Return to text ↑
  2. Texas Instruments — PGA302 signal conditioner for resistive bridge sensors (SLDS216B, rev. Feb 2025) ↗ Manufacturer data sheet Return to text ↑
  3. Renesas — ZSSC3241 Sensor Signal Conditioner IC for Resistive Sensors, data sheet ↗ Manufacturer data sheet Return to text ↑

Still to check yourself

  • Confirm the compensation order of the exact part.
  • Fix the pressure and temperature calibration points.
  • Freeze front-end settings before calibration.
  • Verify the stored coefficients by CRC or read-back.
Buyer enquiry

Request manufacturing insight for Calibration circuit

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Calibration circuit?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
XY Positioning Stage
Last Product
Get QuotesChat