This page explains how Voltage Sensor Circuit is classified within Computer, Electronic and Optical Product Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
A specialized electronic circuit designed to measure and monitor electrical voltage levels within a power grid system.
Technical details and manufacturing context for Voltage Sensor Circuit
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Input Voltage Range | 0–1000 V AC/DC | Exceeding range may damage sensorIEC 61000-4-30 |
| Output Signal | 0–10 V DC | Analog output proportional to input |
| Accuracy | ±0.5 % | Class 0.5 for meteringIEC 62053-22 |
| Response Time | <10 ms | For transient detection |
| Operating Temperature | -40–85 °C | Outside range may affect accuracyIEC 60068-2-1/2 |
| Storage Temperature | -40–105 °C | Non-operating conditionIEC 60068-2-1/2 |
| Humidity | 5–95 % RH | Non-condensingIEC 60068-2-78 |
| Ingress Protection | IP54–IP65 | For outdoor installationIEC 60529 |
| Insulation Resistance | >100 MΩ | At 500 V DCIEC 60255-5 |
| Dielectric Strength | 2.5 kV | For 1 minuteIEC 60255-5 |
| Power Supply | 24 ±10% V DC | Reverse polarity protected |
| Power Consumption | <2 W | At nominal supply |
| Weight | 150–300 g | Depends on enclosure |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
Commonly used trade names and technical identifiers for Voltage Sensor Circuit.
This component is essential for the following industrial systems and equipment:
| accuracy: | ±0.5% of reading |
| temperature: | -40°C to +85°C |
| voltage range: | 0-1000V AC/DC |
| frequency range: | 45-65Hz (standard), up to 400Hz (optional) |
| isolation voltage: | 2500V RMS |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
Manufacturer profiles associated with Voltage Sensor Circuit.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The input voltage range is 0–1000 V AC/DC, as listed in the parameters. Exceeding this range may damage the sensor. Always verify the specific model's range with the manufacturer.
The circuit provides an analog output signal of 0–10 V DC, proportional to the input voltage. This output can be connected to monitoring equipment for further processing.
The accuracy is ±0.5% per IEC 62053-22, which is suitable for metering applications. However, actual accuracy may vary with operating conditions, so verify with the supplier.
The operating temperature range is -40 to 85 °C, storage temperature -40 to 105 °C, and humidity 5–95% RH non-condensing. Ingress protection is IP54–IP65 for outdoor use. Confirm these limits for your specific model.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.