Switch-mode power transformers · Topology and frequency, ferrite grade and core loss, core size against power, inductance tolerance, insulation and hi-pot
A high-frequency transformer is the ferrite-cored transformer inside a switch-mode power supply, inverter or charger, working at tens or hundreds of kilohertz so that it can be far smaller than a mains-frequency unit. Fix three things before asking for a design: the converter topology, switching frequency and power, the core material and size that keep losses and flux density in bounds, and the insulation and safety tests the mains-connected design must pass.
Ferrite-core transformers for flyback, forward, half-bridge, full-bridge and LLC converters from a few watts to kilowatts, and high-frequency dry-type units for power conversion equipment. Mains-frequency (50/60 Hz) power transformers, current transformers, inductors and chokes, and ferrite cores sold alone are outside this page; power transformers and current transformers have their own pages.
Start with your task
01
Ferroxcube describes 3C90 as a low-frequency power ferrite for power and general-purpose transformers at frequencies up to 0.2 MHz, and 3C95 as a low-to-medium-frequency power ferrite with low losses from 25 to 100 °C for power transformers up to 0.5 MHz. [2] [1] For 3C95 it lists initial permeability 3,000 ±20%, saturation flux density about 530 mT at 25 °C and 410 mT at 100 °C, core loss of about 350 kW/m³ at 25 °C and 290 kW/m³ at 100 °C (100 kHz, 200 mT), and a Curie temperature of at least 215 °C. For 3C90 it lists saturation about 470 mT at 25 °C and 380 mT at 100 °C and core loss of at most 80 kW/m³ at 100 kHz and 100 mT (100 °C). [1] [2]
A linked maker of high-frequency transformers tabulates core shapes by power band for its FW40 and FW44 ferrite grades: RM4, P11/7, EF12.6 and U10 below 5; RM8, P22, RM10, ETD29, E25 and EFD20 for 20 to 50; ETD29, ETD34, RM12, P30 and EFD25 for 50 to 100; and ETD44, ETD49 and E55 for 200 to 500. The page does not state the unit; read it as watts and confirm. [4]
Editorial calculation: 290 kW/m³ equals 0.29 W/cm³, so a ferrite core with 10 cm³ of effective volume run at 100 kHz and 200 mT at 100 °C would lose about 2.9 W in the core alone, before copper loss. Halving the flux swing lowers core loss sharply, as the 3C90 figures at 100 mT and 200 mT show (≤80 versus about 450 kW/m³). [1] [2]
Editorial note: saturation falls as the core heats — about 530 to 410 mT for 3C95 between 25 and 100 °C — so check peak flux density at the hottest operating temperature. [1]
Give the supplier the topology (flyback, forward, half-bridge, full-bridge, LLC), input voltage range, output voltages and currents, switching frequency, power, primary inductance and tolerance, leakage-inductance limit, insulation system and safety standard, hi-pot test voltage, core shape or footprint limits, pin layout, operating temperature and quantity.
02
A linked maker publishes a reference EE42 flyback/switching transformer (vertical 6+6 pins, 43 × 31 × 45 mm maximum) with primary inductance of 450 µH ±5% at 1 kHz/0.3 V, DCR of 90 mΩ maximum and an operating frequency of 20–500 kHz, and states inductance ranges of 10 µH to 10 mH at ±3% or ±5%. [3] It describes multi-layer insulation using triple-insulated wire or margin tape to meet hi-pot requirements of 3,000 V AC and above, testing at 3,000–4,000 V AC primary to secondary, and design for flyback, forward, half-bridge and LLC topologies. [3]
Another linked maker lists high-frequency dry-type transformers for 1 kHz to 100 kHz and above, from 100 VA to 500 kVA, with ferrite or amorphous/nanocrystalline cores, multi-layer insulation and windings arranged to reduce parasitic capacitance and leakage inductance. [5]
Editorial note: the hi-pot voltage, creepage and clearance follow from the safety standard and insulation class of the end product. State them in the request rather than relying on a maker's default, and ask for the insulation construction (triple-insulated wire or margin tape) on the drawing.
03
Suppliers linked to this page list high-frequency transformers; each card links to the page reviewed.
The listings reviewed range from small EE, EFD and RM SMPS transformers and flyback units to high-power ferrite and dry-type high-frequency transformers; ask each for the ferrite grade, core loss at your frequency and flux, inductance tolerance, leakage inductance and hi-pot test level.
04
This is a functional reference built from the sources cited; it is not one maker's specification.
| Part | Role | Fix in the order |
|---|---|---|
| Ferrite core | Frequency range, loss, saturation. [2] [1] | Grade; shape; size. |
| Core shape | EE, EI, PQ, EFD, ETD or RM. [3] [4] | Shape; footprint. |
| Windings | Copper loss; DCR. [3] | Wire; turns; DCR. |
| Insulation system | TIW or margin tape; hi-pot. [3] [5] | Construction; test kV. |
| Bobbin and pins | Footprint and creepage. [3] | Pin layout; size. |
| Impregnation or potting | Mechanical and humidity protection. [3] [5] | Varnish; potting. |
05
A high-frequency transformer quotation needs values for your converter. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Rated Power (W) | Core shape bands from <5 to 200–500 (unit to confirm). [4] | Power and core. |
| Operating Frequency (kHz) | 3C90 to 200 kHz; 3C95 to 500 kHz; example 20–500 kHz. [2] [1] [3] | Switching frequency. |
| Primary Inductance (mH) | Example: 0.45 mH ±5%. [3] | Value; tolerance; test condition. |
| Leakage Inductance (µH) | Reduced by winding arrangement. [5] | Limit. |
| Isolation Voltage (kV) | Hi-pot 3–4 kV AC primary to secondary. [3] | Test voltage; duration. |
| Efficiency (%) | Core plus copper loss. [1] | Loss budget. |
| Operating Temperature (°C) | 3C95 Curie ≥215 °C; saturation falls with heat. [1] | Range; hot-spot. |
| Insulation Class | Thermal class of materials. [5] | Class. |
| Core Material | Ferrite grade or amorphous/nanocrystalline. [1] [5] | Grade. |
| Wire Material | Copper, TIW, litz. | Type. |
| Weight (g) | Per part. | Weight. |
| Dimensions (L×W×H) (mm) | Example EE42: 43 × 31 × 45 max. [3] | Drawing. |
06
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Converter: [topology; frequency; power] Input: [voltage range] Outputs: [voltages; currents] Magnetics: [inductance; tolerance; leakage limit] Core: [grade; shape; size limit] Safety: [standard; hi-pot kV; creepage] Mechanical: [pins; footprint; potting] Environment: [temperature; humidity]
These companies list high-frequency transformers.
Lists EE-core SMPS and custom high-frequency transformers for flyback, forward, half-bridge and LLC designs, hi-pot tested at 3–4 kV AC.
Product scope checked 2026-10-11
Lists high-frequency PCB power transformers with core shapes tabulated by power band.
Product scope checked 2026-10-11
Lists high-frequency dry-type transformers from 100 VA to 500 kVA for 1 kHz to 100 kHz and above.
Product scope checked 2026-10-11
Lists high-frequency, flyback, isolation and high-power high-frequency transformers.
Product scope checked 2026-10-11
Lists SMPS transformers alongside current sensors and power inductors.
Product scope checked 2026-10-11
Lists high-frequency transformers alongside power and audio transformers.
Product scope checked 2026-10-11
Lists switching transformers among its magnetic components.
Product scope checked 2026-10-11
Lists high-frequency transformers among its inductors and transformers.
Product scope checked 2026-10-11
Lists high-frequency transformers among its power and current transformers.
Product scope checked 2026-10-11
Lists high-frequency transformers alongside custom ferrite cores.
Product scope checked 2026-10-11
Lists electronic transformers and SMPS transformer bobbins and frames.
Product scope checked 2026-10-11
Lists high-frequency transformers in its electronic components catalogue.
Product scope checked 2026-10-11
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
Ferroxcube lists 3C95 for power transformers at frequencies up to 0.5 MHz. [1]
Ferroxcube lists about 290 kW/m³ for 3C95 at 100 kHz, 200 mT and 100 °C. [1]
A linked maker tests its transformers at 3,000–4,000 V AC primary to secondary. [3]
One maker lists ETD29, ETD34, RM12, P30 and EFD25 for the 50 to 100 band. [4]
Sources checked 2026-10-11. Ferroxcube is a ferrite maker publishing material data sheets; Magsonder, Gold-Stone and Lugao are linked transformer makers publishing reference specifications and core-size guidance.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.