Solenoid Coil Assembly

This page explains how Solenoid Coil Assembly is classified within Electrical Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.

Technical Definition & Core Assembly

Electromagnetic component that converts electrical energy into mechanical motion to actuate contactor switching

Representative product image. Confirm appearance and specifications with the manufacturer.

Product Specifications

Technical details and manufacturing context for Solenoid Coil Assembly

Definition
The Solenoid Coil Assembly is a critical subassembly within the Medium Voltage Vacuum Contactor Actuator Module. It consists of wound copper wire around a bobbin or core, designed to generate a magnetic field when energized, which drives the mechanical linkage to open or close the vacuum contactor contacts for medium voltage circuit control applications. The assembly includes enamel-insulated copper wire, a bobbin typically made of PBT or nylon, terminal pins or connectors, and insulation materials such as varnish, tape, and sleeve. Key parameters include a standard coil voltage of 24 V DC (±10%), with other voltages available on request; coil power consumption of 8–12 W (holding power, inrush may be higher); insulation class F (155 °C) standard, with class H optional per IEC 60085; dielectric strength of 2.5 kV for 1 minute per IEC 60947; insulation resistance of ≥100 MΩ at 500 V DC per IEC 60255; operating temperature range of -40 to 85 °C with derating above 70 °C; relative humidity ≤95% non-condensing per IEC 60068-2-78; degree of protection IP54–IP65 per IEC 60529; coil resistance of 20–80 Ω at 20 °C (±10%); pull-in voltage ≤85% and drop-out voltage ≥10% of rated voltage per IEC 60947; mechanical life ≥10 million operations under normal load conditions per IEC 60947; and weight of 0.15–0.35 kg depending on coil size and encapsulation. These values are directory reference ranges and must be confirmed for the actual model and application. The assembly operates on the principle that when electrical current flows through the coil, it generates a magnetic field according to Ampere's law, interacting with ferromagnetic components to produce mechanical motion. It is used in medium voltage contactors for switching and control. When selecting, verify the coil voltage, power, insulation class, and environmental ratings with the legal manufacturer or supplier. Regular inspection for insulation resistance and dielectric strength is recommended to detect degradation. Failure modes include coil burnout due to overvoltage or overheating, insulation breakdown, and mechanical wear of the linkage. Always consult the manufacturer for specific application requirements.
Working Principle
When electrical current flows through the wound copper coil, it generates a magnetic field according to Ampere's law. This magnetic field interacts with ferromagnetic components (typically a plunger or armature), creating electromagnetic force that produces linear or rotational mechanical motion to actuate the contactor mechanism. The force is proportional to the number of turns and the current, and the motion is used to open or close the vacuum contactor contacts. The coil is designed to operate within specified voltage and temperature ranges to ensure reliable actuation. The magnetic circuit is optimized to provide sufficient force while minimizing power consumption and heat generation. The plunger or armature moves against a spring or other return mechanism, and the contactor remains in the actuated state as long as the coil is energized. When the current is removed, the magnetic field collapses, and the return mechanism resets the contacts.
Common Materials
Copper wire (enamel insulated), Bobbin (typically PBT or nylon), Terminal pins/connectors, Insulation materials (varnish, tape, sleeve)
Technical Parameters
ParameterTypical rangeNotes & selection driver
Coil Voltage24 ±10% V DCStandard control voltage; other voltages available on request.
Coil Power Consumption8–12 WHolding power; inrush may be higher.
Insulation ClassFClass F (155 °C) standard; Class H optional.IEC 60085
Dielectric Strength2.5 kVTest voltage for 1 minute.IEC 60947
Insulation Resistance≥100 At 500 V DC.IEC 60255
Operating Temperature Range-40–85 °CContinuous operation; derating above 70 °C.
Relative Humidity≤95 %Non-condensing.IEC 60068-2-78
Degree of ProtectionIP54–IP65Depends on housing and sealing.IEC 60529
Coil Resistance20–80 ΩAt 20 °C; tolerance ±10%.
Pull-in Voltage≤85 %Percentage of rated voltage.IEC 60947
Drop-out Voltage≥10 %Percentage of rated voltage.IEC 60947
Mechanical Life≥10 million operationsUnder normal load conditions.IEC 60947
Weight0.15–0.35 kgDepends on coil size and encapsulation.

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Components / BOM
  • Coil Winding Part
    Conducts electrical current to generate magnetic field
    Material: Copper wire with enamel insulation
  • Bobbin Part
    Provides structural support and insulation for the coil winding
    Material: PBT (Polybutylene terephthalate) or nylon
  • Terminal Assembly Part
    Electrical connection points for power supply
    Material: Brass or copper with plating
  • Insulation Sleeve/Tape Part
    Provides electrical insulation between winding layers and to ground
    Material: Polyester film, Nomex, or fiberglass

Industrial Ecosystem & Supply Chain Structure

Complementary Systems
Downstream Applications
Specialized Tooling

Application Fit & Sizing Matrix

Operational Limits
pressure: Atmospheric to 2 bar (typical), vacuum compatible
other spec: Voltage range: 12-240V DC/AC, Duty cycle: 100% ED, Insulation class: F (155°C)
temperature: -40°C to +85°C (operating), up to +130°C (peak)
Media Compatibility
✓ Clean dry air systems ✓ Hydraulic oil circuits ✓ Industrial water (non-corrosive)
Unsuitable: Corrosive chemical environments (acids, strong solvents)
Sizing Data Required
  • Required force/stroke (N/mm)
  • Supply voltage/frequency (V/Hz)
  • Duty cycle/operating frequency (%)

Reliability & Engineering Risk Analysis

Failure Mode & Root Cause
Coil burnout
Cause: Overvoltage, excessive current due to mechanical binding or shorted turns, leading to insulation breakdown and overheating.
Mechanical binding or sticking
Cause: Contamination (dirt, debris), corrosion, or misalignment of the plunger/armature, preventing proper movement and causing overheating or failure to actuate.
Maintenance Indicators
  • Audible buzzing or humming during operation, indicating insufficient magnetic pull due to voltage issues or mechanical obstruction.
  • Visible overheating (discoloration, burning smell) or intermittent operation, suggesting coil degradation or electrical faults.
Engineering Tips
  • Ensure proper voltage supply and use surge protection to prevent overvoltage events that degrade coil insulation.
  • Implement regular cleaning and inspection of the plunger/armature assembly to prevent contamination buildup and ensure smooth mechanical movement.

Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.

Compliance & Manufacturing Standards

Applicable Standards
IEC 60034-1 Rotating Electrical Machines CE Marking (EU Machinery Directive 2006/42/EC)

Quoted from the published standard.

Manufacturing Precision
  • Coil Winding Resistance: +/-5% of nominal value
  • Solenoid Bore Diameter: +/-0.05mm
Quality Inspection
  • Insulation Resistance Test (minimum 100 MΩ at 500VDC)
  • Pull Force Test at rated voltage and temperature

Manufacturers of Solenoid Coil Assembly

Manufacturer profiles associated with Solenoid Coil Assembly.

Sourcing Solenoid Coil Assembly from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Supply Chain Compatible Machinery & Devices

Motor Terminal Block

A motor terminal block is a standardized electrical component that provides secure, insulated connection points for motor winding leads.

Explore Specs →
PLC Control System

A digital industrial computer control system that monitors inputs, makes decisions based on a custom program, and controls outputs to automate industrial processes.

Explore Specs →
Control Panel

A centralized interface for monitoring and controlling industrial equipment and processes

Explore Specs →
PLC Control Panel

A centralized interface unit housing the programmable logic controller and associated control components for industrial automation systems.

Explore Specs →

Frequently Asked Questions

What is the standard coil voltage for this solenoid coil assembly?

The standard coil voltage is 24 V DC with a tolerance of ±10%. Other voltages are available on request, but you must confirm the exact voltage with the legal manufacturer or supplier for your specific application.

What insulation class is standard for this coil?

The standard insulation class is Class F, which corresponds to a maximum operating temperature of 155 °C, according to IEC 60085. Class H is optional. Always verify the insulation class required for your application with the manufacturer.

What is the dielectric strength of this coil?

The dielectric strength is 2.5 kV for 1 minute, tested according to IEC 60947. This is a reference value; the actual value may vary depending on the specific model and must be confirmed with the manufacturer.

What is the operating temperature range?

The operating temperature range is -40 to 85 °C, with derating above 70 °C. This means that at higher temperatures, the coil's performance may be reduced. Always check the manufacturer's specifications for your specific application.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.
Buyer enquiry

Request manufacturing insight for Solenoid Coil Assembly

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What we don't claim
A listing is not an endorsement. Qualify every supplier and verify every figure yourself before ordering.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at contact@cnfx.com.

Need to Manufacture Solenoid Coil Assembly?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Wire Tensioning System
Last Product
Get QuotesChat