Component Specifications

Definition
The Frame/Base is the foundational structural component of a Drum Clamping Unit, engineered to withstand operational loads, maintain geometric stability, and provide precise mounting surfaces for clamping mechanisms, actuators, and alignment systems. It ensures dimensional integrity under dynamic forces during material handling processes.
Working Principle
Provides static structural support through rigid geometry and material strength, distributing clamping forces and operational vibrations to prevent deflection, maintaining alignment between drum and clamping elements throughout the operational cycle.
Materials
ASTM A36 steel plate (10-25mm thickness), welded construction with stress-relief annealing, surface machined to Ra 3.2μm flatness, corrosion-resistant epoxy coating (RAL 7012).
Technical Parameters
ParameterTypical rangeNotes & selection driver
Weight80-300 kg
Load Capacity5000-15000 N
Natural Frequency>50 Hz
Flatness Tolerance±0.1mm/m²
Mounting Hole PatternISO 2768-mK

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Standards
ISO 12100, DIN 15018, ISO 8525

Parent Products

This component is used in the following industrial products

Engineering Analysis

Risks & Mitigation
  • Structural fatigue from cyclic loading
  • Corrosion in humid environments
  • Resonance vibration at specific frequencies
  • Thermal expansion misalignment
FMEA Triads
Trigger: Inadequate material thickness
Failure: Excessive deflection under load
Mitigation: Implement finite element analysis during design, specify minimum thickness based on load calculations
Trigger: Improper welding procedure
Failure: Stress concentration and crack propagation
Mitigation: Follow AWS D1.1 welding standards, perform post-weld heat treatment, conduct non-destructive testing

Industrial Ecosystem

Compatible With

Typical Suppliers & Equivalents

Compliance & Inspection

Tolerance
Geometric tolerances per ISO 1101, flatness ≤0.1mm, parallelism ≤0.05mm/100mm
Test Method
Laser alignment verification, static load testing to 150% rated capacity, modal analysis for vibration characteristics

Procurement Evaluation Criteria

A practical evidence checklist for RFQ preparation and supplier evaluation.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

Compare the published product scope and source details, then include your specifications and quantity in an enquiry.

Manufacturers of Frame/Base

1 company lists this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.

Singamas Container Holdings Limited
Shanghai, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “20' Frame Base”
View source page ↗ singamas.com · recorded 2026-09-14

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Related Components

Mounting Interface
Precision mounting interface connecting punch tips to pharmaceutical tablet press machines for accurate tablet production.
Chrome Plating
Hard chrome plating is an electroplating process that deposits a layer of chromium onto metal surfaces to enhance wear resistance, corrosion protection, and reduce friction for hydraulic cylinder piston rods.
Upper Tool (Punch)
Upper Tool (Punch) is the active forming component in metal plate bending machines that applies precise downward force to create bends in sheet metal.
Main Frame
The main frame is the primary structural component of a hydraulic press, providing rigidity and stability to withstand high compressive forces during metal forming operations.

Frequently Asked Questions

What are the critical tolerances for drum clamping unit frames?

Flatness tolerance of ±0.1mm/m² and perpendicularity within 0.05mm/100mm are critical for proper drum alignment and clamping force distribution.

How does frame design affect clamping unit performance?

Proper frame rigidity prevents deflection under load, maintaining precise drum positioning and ensuring consistent clamping pressure across the contact surface.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records. See the editorial policy.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.

Request Manufacturing Insight for Frame/Base

Thank you. Your request has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].
Frame Structure Friction Discs
Get QuotesChat