Technical Definition & Core Assembly

A structural frame designed to securely mount and support a hydraulic pump within machinery.

Representative product image. Confirm appearance and specifications with the manufacturer.

Product Specifications

Technical details and manufacturing context for Hydraulic Pump Mounting Frame

Definition
The Hydraulic Pump Mounting Frame is a specialized structural component used in machinery and equipment manufacturing. It provides a rigid, vibration-resistant platform for mounting hydraulic pumps, ensuring proper alignment and reducing stress on pump components. The frame transfers the weight and operational forces of the pump to the main structure while isolating vibrations, maintaining precise pump positioning for correct fluid connections and drive system alignment. It is designed to facilitate maintenance access and maintain structural integrity under operational loads.

Typical materials include carbon steel and stainless steel, with frame material grades such as Q235B for standard applications and 45# for high-strength requirements, per GB/T 700. Surface treatment options include phosphating plus powder coating for indoor use, with hot-dip galvanizing recommended for outdoor environments. The frame is available in various configurations, with footprint dimensions ranging from 400×300 mm to 800×600 mm, and weight typically between 15 and 60 kg, depending on pump size and configuration.

Key parameters include a rated pressure range of 16–31.5 MPa, with special seals and thicker flanges required above 31.5 MPa. Mounting hole diameters range from Ø13 to Ø26 mm to match standard bolts M12–M24 (ISO 273). Center distance tolerance is ±0.05 mm (ISO 2768-m), and flatness is 0.10 mm (ISO 1101) to prevent distortion and vibration. The operating temperature range is -20 to +80 °C; outside this range, high-temperature or low-temperature steel should be used. Vibration resistance is tested at 5–500 Hz, 2.5 g (IEC 60068-2-6), with damping mounts required above 2.5 g.

All values are reference ranges and must be verified for the specific model and application with the legal manufacturer or supplier. Standards listed are procurement references and do not imply certification or compliance.
Working Principle
The frame operates by providing a rigid base that supports the hydraulic pump and transfers its weight and operational forces to the main machinery structure. It isolates vibrations through its structural design and material properties, reducing stress on pump components. The frame maintains precise pump positioning, ensuring proper alignment with fluid connections and drive systems. This alignment is critical for efficient operation and to prevent premature wear. The frame's flatness and center distance tolerance are controlled to avoid distortion and misalignment. Maintenance access is facilitated by the frame's design, allowing for inspection and service without compromising structural integrity.
Common Materials
Carbon Steel, Stainless Steel
Technical Parameters
ParameterTypical rangeNotes & selection driver
Rated Pressure16–31.5 MPaAbove 31.5 MPa requires special seals and thicker flanges.
Frame MaterialQ235B / 45#Q235B for standard, 45# for high-strength applications.GB/T 700
Surface TreatmentPhosphating + powder coatingCorrosion resistance for indoor use; hot-dip galvanizing for outdoor.
Mounting Hole DiameterØ13–Ø26 mmMatches standard bolts M12–M24.ISO 273
Center Distance Tolerance±0.05 mmEnsures alignment with pump mounting flange.ISO 2768-m
Flatness0.10 mmPrevents distortion and vibration.ISO 1101
Operating Temperature-20–+80 °COutside this range, use high-temp or low-temp steel.
Vibration Resistance5–500 Hz, 2.5 gTested for 2 hours per axis; above 2.5 g requires damping mounts.IEC 60068-2-6
Weight15–60 kgDepends on pump size and frame configuration.
Footprint Dimensions400×300 – 800×600 mmCustomizable to match pump and motor layout.

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Components / BOM
  • Base Plate Part
    Primary mounting surface for hydraulic pump attachment
    Material: steel
  • Support Beams Part
    Provide structural rigidity and distribute load to main structure
    Material: steel
  • Mounting Brackets Part
    Secure the pump to the base plate with vibration isolation
    Material: steel
  • Alignment Pins Part
    Ensure precise positioning of pump during installation
    Material: hardened steel

Industry Taxonomies & Aliases

Commonly used trade names and technical identifiers for Hydraulic Pump Mounting Frame.

Applied To / Applications

This component is essential for the following industrial systems and equipment:

Industrial Ecosystem & Supply Chain Structure

Complementary Systems
Downstream Applications
Specialized Tooling

Application Fit & Sizing Matrix

Operational Limits
pressure: Up to 5000 psi (345 bar) system pressure
other spec: Flow Rate: Up to 100 GPM (378 L/min), Vibration Tolerance: ≤ 5 g RMS, Slurry Concentration: Not applicable (clean hydraulic fluids only)
temperature: -20°C to 120°C
Media Compatibility
✓ Mineral-based hydraulic oils ✓ Synthetic hydraulic fluids (e.g., phosphate esters) ✓ Water-glycol hydraulic fluids
Unsuitable: Corrosive chemical environments (e.g., acids, chlorides) or saltwater immersion
Sizing Data Required
  • Pump weight and dimensions (including motor if integrated)
  • Required mounting bolt pattern and interface specifications
  • Maximum dynamic load from pump operation (including vibration and torque forces)

Reliability & Engineering Risk Analysis

Failure Mode & Root Cause
Fatigue cracking
Cause: Cyclic stress from pump vibration and hydraulic pressure pulses, often exacerbated by improper alignment or inadequate frame stiffness
Corrosion-induced weakening
Cause: Exposure to moisture, hydraulic fluid leaks, or corrosive environments leading to material degradation and loss of structural integrity
Maintenance Indicators
  • Visible cracks or deformation in the frame welds or mounting points
  • Abnormal vibration or audible knocking sounds during pump operation indicating loose mounting
Engineering Tips
  • Implement regular alignment checks and use vibration analysis to detect early stress concentrations before cracks develop
  • Apply protective coatings and ensure proper sealing to prevent fluid ingress and corrosion, especially in weld zones

Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.

Compliance & Manufacturing Standards

Applicable Standards
ISO 4401: Hydraulic fluid power - Four-port directional control valves - Mounting surfaces ANSI/B93.5M: Hydraulic Fluid Power - Mounting Dimensions for Single and Double Rod Cylinders DIN 24340: Hydraulic fluid power - Mounting surfaces for pumps and motors - Dimensions

Quoted from the published standard.

Manufacturing Precision
  • Mounting surface flatness: 0.05mm per 100mm
  • Bolt hole position tolerance: +/-0.1mm
Quality Inspection
  • Surface plate inspection for flatness and parallelism
  • Dimensional verification with CMM (Coordinate Measuring Machine)

Manufacturers of Hydraulic Pump Mounting Frame

Manufacturer profiles associated with Hydraulic Pump Mounting Frame.

Sourcing Hydraulic Pump Mounting Frame from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Supply Chain Compatible Machinery & Devices

Automated Powder Coating System

Integrated industrial system for applying dry powder coatings to metal substrates.

Explore Specs →
Centrifugal Pump Impeller

The centrifugal pump impeller is a critical rotating component that converts mechanical energy from the motor into kinetic energy in fluid systems.

Explore Specs →
High-Precision CNC Laser Cutting Machine

Computer-controlled industrial machine using focused laser beams to cut sheet metal with micron-level accuracy.

Explore Specs →
Industrial-Grade Hydraulic Cylinder Piston Rod

This industrial-grade piston rod is a precision-ground cylindrical component designed for use in hydraulic cylinders.

Explore Specs →

Frequently Asked Questions

What materials are available for the mounting frame?

The frame is typically made from carbon steel or stainless steel. Specific grades include Q235B for standard applications and 45# for high-strength requirements, as per GB/T 700. The choice depends on the application's strength and corrosion resistance needs.

What is the rated pressure range for this frame?

The rated pressure range is 16–31.5 MPa. For pressures above 31.5 MPa, special seals and thicker flanges are required. Always verify the actual pressure rating for your specific model with the manufacturer.

How is the frame surface treated?

Standard surface treatment is phosphating plus powder coating, suitable for indoor use. For outdoor applications, hot-dip galvanizing is recommended to enhance corrosion resistance. Confirm the appropriate treatment for your environment.

What are the mounting hole diameters?

Mounting hole diameters range from Ø13 to Ø26 mm, designed to match standard bolts M12–M24 (ISO 273). Ensure the bolt size and hole diameter are compatible for secure mounting.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.
Buyer enquiry

Request manufacturing insight for Hydraulic Pump Mounting Frame

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What we don't claim
A listing is not an endorsement. Qualify every supplier and verify every figure yourself before ordering.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at contact@cnfx.com.

Need to Manufacture Hydraulic Pump Mounting Frame?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Hydraulic Press
Next Product
Hydraulic System
Get QuotesChat