Editorial Technical Reference

Fuel tank

Fuel tanks for vehicles and machinery · steel, aluminium and multilayer HDPE construction, capacity and 95% fill limit, venting and overfill protection, sender and fitting ports, crash integrity (FMVSS 301), FMCSA tank tests (49 CFR 393.67), EPA nonroad permeation limits (40 CFR 1060)

A fuel tank stores diesel, gasoline or alcohol-blend fuel for an engine and feeds it to the fuel pump through fittings for the sender, withdrawal and return lines, filler and vents. Truck tanks reviewed here are welded aluminised steel; coextrusion blow-molded tanks for motor vehicles use multilayer HDPE with an EVOH barrier. Ask three things first: the usable capacity and the space envelope it must fit; the wall material and thickness; and which rules it must pass — FMCSA tank tests, FMVSS 301 crash integrity or EPA evaporative limits.

Fuel tanks for road vehicles, trucks and buses and for nonroad equipment and construction machinery: welded steel, aluminised steel and aluminium tanks, and coextrusion blow-molded multilayer HDPE tanks, including side-mounted and midship replacement tanks. Fuel pumps, filler necks sold alone, hydraulic oil tanks, CNG and LPG containers and DOT refuelling (transfer) tanks are outside this page except where compared.

CNFX editorial research · Sources checked October 11, 2026 · 6 sources

01

Fix the capacity, wall material and fittings

Transfer Flow's replacement tanks for pickups and cab-chassis trucks show the capacity range of one maker's catalogue: 40, 45, 46, 50 and 58 gallon models, built from 12- and 14-gauge aluminised steel and fully baffled to reduce fuel sloshing. [4] Its regulations page states that its tanks use high-yield 14-gauge aluminised steel as a minimum, are pressure tested for leaks, and that liquid-filled tanks are subjected to a 30-foot drop test; it warns never to apply more than 3 psi to its tanks and never to connect 12 volts directly to the sending unit, which would burn out the sender resistor. [5]

For plastic tanks, Kuraray's patent US7208210B2 describes a coextrusion blow-molded fuel container whose example 35-liter tank, with 0.85 m² surface area, has five layers — outer HDPE, adhesive resin, EVOH barrier, adhesive resin, inner HDPE — of 2500/100/150/100/2500 μm. The patent identifies the pinch-off seam and the joints where components are attached as paths for fuel permeation that a barrier member can cover. [6]

FMCSA requires the tank body to have flanges or spuds for all fittings, Dryseal taper pipe threads (SAE J476) with at least four full threads engaged, drains and bottom fittings no more than three-fourths of an inch below the tank and protected from impact, and joints closed by welding, brazing or silver soldering — not by crimping or soft solder alone. [1]

Editorial calculation: at 3.785 L per US gallon, the 40–58 gallon range above is about 151–220 L; the 95% fill limit leaves a 58 gallon tank about 55 gallons (about 209 L) of fill. The Kuraray example wall totals 2500 + 100 + 150 + 100 + 2500 = 5,350 μm (5.35 mm), with the EVOH barrier about 2.8% of it. [4] [1] [6]

Give the supplier the fuel (diesel, gasoline, alcohol blend), usable and nominal capacity, the space envelope and mounting (frame rail, side-mounted, midship), wall material, alloy and gauge or layer structure, baffles, sender type and port, withdrawal, return and vent fittings with thread standard, filler location and fill rate, venting and rollover valve, drain, finish, the rules it must certify to, test reports, marking and quantity.

02

Check the safety and emission rules the tank must pass

49 CFR 393.67 applies to liquid fuel tanks on commercial motor vehicles. Tanks must not fill beyond 95% of liquid capacity in a normal filling operation, and must carry a nonspill air vent such as a ball check. Above 25 gallons, a tank needs a safety venting system that activates in a fire test before internal pressure exceeds 50 psi, and its body and fittings must withstand 150% of the maximum pressure reached in that test. Diesel tanks above 94.75 L must accept fuel at 75.8 L/min without spillage. Filled and turned through 150°, a tank may leak no more than one ounce of fuel per minute; side-mounted tanks must also pass a 30-foot corner drop and a 10-foot fill-pipe drop. Tanks are marked with the month and year of manufacture, the manufacturer's name and an FMCSA conformity statement. [1]

Under 49 CFR 393.65, no part of a fuel tank may sit forward of the front axle of a power unit, fuel spilled while filling must not reach the exhaust or electrical systems except the fuel level indicator assembly, and an unenclosed fuel line may not extend more than 2 inches below the tank. Vehicles meeting FMVSS 301 are exempt from these requirements as they apply to the vehicle's fuelling system. [1]

FMVSS 301 (49 CFR 571.301) applies to passenger cars and to trucks, buses and multipurpose vehicles of 4,536 kg GVWR or less, and to heavier school buses. After a frontal barrier crash at up to 48 km/h, a rear moving deformable barrier at 80 km/h with 70% overlap, or a side barrier at 53 km/h, spillage may not exceed 28 g until motion stops and 142 g in the next 5 minutes; static rollover limits apply at each 90° step. Alcohol-fuel vehicles must stop a hose of at least 1200 mm length and 5.2 mm outside diameter from reaching fuel through the filler neck with the tank 90–95% full. [2]

For nonroad spark-ignition equipment, 40 CFR 1060.103 limits fuel tank permeation to 1.5 g/m²/day at 28 °C, or 2.5 g/m²/day if tested at 40 °C; fittings mounted directly to the tank, such as caps, gaskets and O-rings, count as part of the tank, and Large SI tanks are covered by the diurnal standard of 1060.105 instead. [3]

Editorial calculation: applied to the 0.85 m² surface of the 35-liter patent example, 1.5 g/m²/day corresponds to about 1.3 g of fuel per day. [3] [6]

03

Drawings and test reports to ask tank suppliers for

When requesting quotations, ask each supplier for the tank drawing with capacity and port positions, material certificates and gauge or layer structure, leak, pressure, venting and drop test reports, and the regulation each tank is certified to.

04

Shell, baffles, ports, vents and drain

ElementRoleFix in the order
ShellAluminised steel, 12–14 gauge, or multilayer HDPE. [4] [6]Material, thickness.
BafflesReduce fuel slosh. [4]Layout.
Fitting flanges and spudsSeat all fittings; Dryseal threads. [1]Thread standard.
Sender portFuel level sending unit. [5] [1]Sender type, flange.
Filler and capFill rate; secure cap. [1]Neck position, cap.
Vents and rollover valveNonspill vent; fire-test venting. [1] [5]Valve type, set pressure.
DrainNo more than ¾ inch below tank. [1]Position, guard.

05

Capacity, wall build-up and leak limits in figures

Gallon and gauge figures from the US sources are converted where the page already does so; the leak, fill and permeation rows are regulatory limits, not one tank's test results.

FieldWhat it means and published valuesAsk the supplier for
Nominal Capacity (L)40–58 gallon (about 151–220 L) catalogue range; 35-liter patent example. [4] [6]Nominal and usable volume.
Burst Pressure (MPa)Above 25 gallons: 150% of fire-test peak pressure. [1]Hydrostatic test value.
Leakage rateNo more than one ounce per minute in 150° test. [1]Leak test method, result.
Operating Temperature (°C)Not stated in reviewed sources.Range and fuel.
Material GradeAluminised steel; HDPE with EVOH barrier. [4] [6]Alloy or resin grade.
Wall Thickness (mm)12–14 gauge steel; 2500/100/150/100/2500 μm layer example, 5.35 mm in total. [4] [6]Gauge or layer drawing.
Weight (kg)Not stated in reviewed sources.Empty mass.
Ingress ProtectionNot stated in reviewed sources.Sender rating.
Electrical Resistance (Ω)Not stated in reviewed sources.Sender range; grounding.
Permeation (g/m²/day)1.5 at 28 °C nonroad limit. [3]Test report.
Overfill limit95% of liquid capacity. [1]Vent and valve design.

06

Send the vehicle, fuel and rules together

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Vehicle or machine: [type; GVWR; mounting position]
Fuel: [diesel; gasoline; alcohol blend]
Capacity: [nominal L; usable L; envelope]
Wall: [steel; aluminium; HDPE layers; thickness]
Fittings: [sender; withdrawal; return; vent; drain; threads]
Rules: [49 CFR 393.67; FMVSS 301; 40 CFR 1060]
Quantity: [units]

See manufacturer records Send an enquiry through CNFX

Fuel tank makers

Yangzhou Changyun Plastic Technology Co.,Ltd. lists multilayer, single-layer and metal fuel tanks in its product categories.

Yangzhou Changyun Plastic Technology Co.,Ltd.
Manufacturing site to be confirmed for the order

Its website has a product page for fuel tank.

Product scope checked 2026-10-12

Product page on own website · profile compiled by CNFX from public sources

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

How full may a commercial-vehicle fuel tank be filled?

49 CFR 393.67 requires that a normal filling operation cannot exceed 95% of the tank's liquid capacity and that fuel expansion causes no spillage. [1]

What permeation limit applies to nonroad equipment fuel tanks?

40 CFR 1060.103 sets 1.5 g/m²/day at 28 °C, or 2.5 g/m²/day when tested at 40 °C. [3]

How are plastic fuel tanks made low-permeation?

Kuraray's patent describes coextrusion blow-molded HDPE tanks with an EVOH barrier layer between adhesive layers, plus barrier members over the pinch-off seam. [6]

Sources and what still needs a direct check

Sources checked 2026-10-11. Three US federal regulations from eCFR, a tank maker's catalogue and regulations pages, and a fuel-container patent; values for your tank must come from the supplier's drawings and test reports.

  1. eCFR — 49 CFR Part 393 Subpart E, Fuel Systems (393.65 All fuel systems; 393.67 Liquid fuel tanks) ↗ US federal regulation Return to text ↑
  2. eCFR — 49 CFR 571.301, FMVSS No. 301 Fuel system integrity ↗ US federal regulation Return to text ↑
  3. eCFR — 40 CFR 1060.103, Permeation emission control requirements for fuel tanks ↗ US federal regulation Return to text ↑
  4. Transfer Flow — Replacement fuel tanks catalogue page ↗ Maker product page Return to text ↑
  5. Transfer Flow — Fuel system regulations ↗ Maker technical page Return to text ↑
  6. Kuraray — US7208210B2 Fuel container (Google Patents full text) ↗ Patent Return to text ↑

Still to check yourself

  • Fix capacity and envelope.
  • Confirm wall material and gauge.
  • Check fittings and sender port.
  • Match the rule set to the vehicle.
  • Verify the legal supplier and factory.
Buyer enquiry

Request manufacturing insight for Fuel Tank

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Fuel Tank?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Vehicle Assembly Unit
Last Product
Get QuotesChat