Editorial Technical Reference

Syringe Holder/Clamp

This page explains how Syringe Holder/Clamp is classified within Machinery and Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.

Technical Definition & Core Assembly

A mechanical component designed to securely hold and position a syringe within a syringe pump assembly.

Representative product image. Confirm appearance and specifications with the manufacturer.

Product Specifications

Technical details and manufacturing context for Syringe Holder/Clamp

Definition
The syringe holder/clamp is a critical component of a syringe pump assembly that provides secure fixation and precise positioning of the syringe barrel. It ensures the syringe remains stable during operation, preventing movement or slippage that could affect fluid delivery accuracy. This component typically interfaces with the pump's drive mechanism to allow controlled plunger movement while maintaining syringe alignment. The holder/clamp uses mechanical force, often through screw tightening, spring tension, or cam mechanisms, to grip the syringe barrel firmly. It may incorporate adjustable features to accommodate different syringe sizes while maintaining consistent clamping pressure. The design ensures the syringe remains coaxial with the pump's drive mechanism for precise linear motion transfer. This directory entry covers general specifications for such components. The clamping range accommodates standard syringe diameters from 10 to 60 mm, with an adjustable clamping force of 20 to 80 N via a thumbscrew. Repeatability is ±0.05 mm, ensuring consistent syringe positioning. Operating temperature ranges from -10 to 60°C, suitable for laboratory environments. Materials on file include stainless steel, aluminum alloy, and engineering plastic; a specific aluminum alloy grade is 6061-T6 with an anodized finish, per ASTM B211. Weight ranges from 0.15 to 0.25 kg, and surface roughness is Ra 0.8 μm per ISO 1302. Mounting hole diameter is 4.2 mm for M4 screws per ISO 273, with mounting hole spacing of 25 to 40 mm for compatibility with standard syringe pump rails. Maximum operating pressure is 0.6 MPa for use with pressurized syringes. Ingress protection is IP54 per IEC 60529, offering dust and splash resistance. These values are reference ranges and must be verified for the specific model and application with the legal manufacturer or supplier. Standards listed are procurement references, not proof of certification or compliance.
Working Principle
The holder/clamp uses mechanical force, often through screw tightening, spring tension, or cam mechanisms, to grip the syringe barrel firmly. It may incorporate adjustable features to accommodate different syringe sizes while maintaining consistent clamping pressure. The design ensures the syringe remains coaxial with the pump's drive mechanism for precise linear motion transfer. The clamping force is adjustable via a thumbscrew, allowing the user to set the appropriate grip for the syringe size and application. The repeatability of ±0.05 mm ensures consistent positioning, which is critical for accurate fluid delivery. The component interfaces with the pump's drive mechanism to allow controlled plunger movement while maintaining syringe alignment.
Common Materials
Stainless Steel, Aluminum Alloy, Engineering Plastic
Technical Parameters
ParameterTypical rangeNotes & selection driver
Clamping Range10–60 mmAccommodates standard syringe diameters
Clamping Force20–80 NAdjustable via thumbscrew
Repeatability±0.05 mmEnsures consistent syringe positioning
Operating Temperature-10–60 °CSuitable for laboratory environments
Material6061-T6Aluminum alloy with anodized finishASTM B211
Weight0.15–0.25 kgLightweight for easy integration
Surface RoughnessRa 0.8 μmSmooth finish reduces frictionISO 1302
Mounting Hole Diameter4.2 mmFor M4 screwsISO 273
Mounting Hole Spacing25–40 mmCompatible with standard syringe pump rails
Max Operating Pressure0.6 MPaFor use with pressurized syringes
Ingress ProtectionIP54Dust and splash resistantIEC 60529

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Components / BOM
  • Clamping Jaw Part
    Directly contacts and grips the syringe barrel surface
    Material: Stainless Steel or Rubber-coated Metal
  • Adjustment Mechanism
    Allows for size adjustment to fit different syringe diameters
    Material: Stainless Steel
  • Mounting Base Part
    Provides attachment interface to the syringe pump assembly
    Material: Aluminum Alloy or Steel
  • Locking Fastener Part
    Secures the clamping position once adjusted
    Material: Stainless Steel
  • Cam Mechanisms Optional
    Cam-driven gripping used instead of screw tightening.
  • Spring Optional
    Provides the gripping force by spring tension instead of a screw.

Industry Taxonomies & Aliases

Commonly used trade names and technical identifiers for Syringe Holder/Clamp.

Applied To / Applications

This component is essential for the following industrial systems and equipment:

Industrial Ecosystem & Supply Chain Structure

Complementary Systems
Downstream Applications
Specialized Tooling

Application Fit & Sizing Matrix

Operational Limits
pressure: 0 to 5 bar
other spec: Flow Rate: 0.1-100 mL/min, Slurry Concentration: ≤10% w/v
temperature: -20°C to 80°C
Media Compatibility
✓ Aqueous solutions ✓ Organic solvents (e.g., ethanol, acetone) ✓ Biological media (e.g., cell culture buffers)
Unsuitable: Highly corrosive media (e.g., concentrated acids, strong oxidizers)
Sizing Data Required
  • Syringe outer diameter (mm)
  • Syringe pump mounting interface type
  • Required clamping force (N)

Reliability & Engineering Risk Analysis

Failure Mode & Root Cause
Clamping force degradation
Cause: Material fatigue or wear in spring mechanisms, leading to insufficient grip on syringes
Corrosion and material degradation
Cause: Exposure to cleaning chemicals, bodily fluids, or environmental moisture compromising structural integrity
Maintenance Indicators
  • Visible corrosion, discoloration, or pitting on metal surfaces
  • Audible clicking or slipping sounds during syringe insertion/removal indicating poor grip
Engineering Tips
  • Implement regular torque/force calibration checks using calibrated test syringes to verify clamping specifications
  • Establish strict cleaning protocols using manufacturer-approved solutions and immediate drying to prevent chemical/moisture damage

Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.

Compliance & Manufacturing Standards

Applicable Standards
ANSI/AAMI ST79:2017 - Comprehensive guide to steam sterilization and sterility assurance in health care facilities DIN EN 285:2015 - Sterilization - Steam sterilizers - Large sterilizers

Quoted from the published standard.

Manufacturing Precision
  • Bore diameter: +/-0.05 mm
  • Surface flatness: 0.1 mm per 100 mm length
Quality Inspection
  • Dimensional verification using coordinate measuring machine (CMM)
  • Material composition verification via X-ray fluorescence (XRF) analysis

Manufacturers of Syringe Holder/Clamp

Manufacturer profiles associated with Syringe Holder/Clamp.

Sourcing Syringe Holder/Clamp from China?
Tell us your specification and target quantity — we will match it against manufacturer records and come back with the factories that fit.
Request manufacturers We manufacture this

Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.

Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.

Supply Chain Compatible Machinery & Devices

Hydraulic Press

Industrial machine using hydraulic pressure to compress, form, or assemble materials

Explore Specs →
Heavy-Duty CNC Plasma Cutting Machine

The Heavy-Duty CNC Plasma Cutting Machine is a standalone industrial device designed for cutting conductive metals such as steel, stainless steel, aluminum, and copper alloys.

Explore Specs →
Automated Powder Coating System

Integrated industrial system for applying dry powder coatings to metal substrates.

Explore Specs →
Centrifugal Pump Impeller

The centrifugal pump impeller is a critical rotating component that converts mechanical energy from the motor into kinetic energy in fluid systems.

Explore Specs →

Frequently Asked Questions

What is the clamping range of this syringe holder/clamp?

The directory lists a clamping range of 10–60 mm to accommodate standard syringe diameters. However, this is a reference range; you must verify the exact range for the specific model with the manufacturer or supplier.

How is the clamping force adjusted?

The clamping force is adjustable via a thumbscrew, with a listed range of 20–80 N. The actual force range may vary by model, so confirm with the manufacturer.

What materials are available for this component?

Materials on file include stainless steel, aluminum alloy, and engineering plastic. A specific aluminum alloy is 6061-T6 with an anodized finish, per ASTM B211. Confirm material availability for your application.

What is the repeatability of the positioning?

The listed repeatability is ±0.05 mm, ensuring consistent syringe positioning. This value is a reference; verify the actual repeatability for the specific model.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.
Buyer enquiry

Request manufacturing insight for Syringe Holder/Clamp

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What we don't claim
A listing is not an endorsement. Qualify every supplier and verify every figure yourself before ordering.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at contact@cnfx.com.

Need to Manufacture Syringe Holder/Clamp?

Compare manufacturer profiles with relevant product and process capability.