Aluminium crimp seals and flip-off caps for injectable vials · Fit to vial and stopper, crimping over the rim, flip-off buttons and tear-off designs, particles and sharp edges, and what may be printed on the top under USP <1>
A pharmaceutical vial aluminium seal (also called a crimp cap, ferrule or cap overseal) holds the rubber stopper on a filled vial: its skirt is crimped under the vial's rim, and a flip-off plastic button or tear-off section exposes the stopper for the needle. Ask three things first: which vial neck and stopper the seal must fit, how it will be crimped on your capping machine, and what colours and printing the product's labelling allows.
Aluminium crimp seals, flip-off seals and tear-off seals for injectable drug vials (including plastic button and combined aluminium–plastic designs). Rubber stoppers, glass vials, all-plastic closures and capping machines are outside this page except where compared.
01
US patent 6,382,442 (Plastic closure for vials and other medical containers) describes the conventional vial: an open end with a radial rim, a reduced-diameter neck and an elastomeric stopper whose planar rim overlies the vial rim, secured by a thin malleable aluminium cap. The cap's tubular portion surrounds the stopper and vial rims, an annular portion overlies the stopper, and its free end is crimped radially into the neck beneath the rim; because aluminium is malleable it accommodates the build-up of dimensional tolerances of the stopper and vial rim, which are set by ISO standards. [1]
The patent explains that closed aluminium caps torn open by a pre-slit tab create sharp edges that can cut gloves or the user and metal particles that can contaminate the drug; adding a plastic flip-off cap riveted to a central opening, which tears out a serrated ring when flipped off, reduces but does not remove these problems, and aluminium dust is still created when the collar is formed, crimped and the flip-off cap removed. [1]
Editorial note: give the supplier the vial neck finish and stopper drawing, and ask for crimp trials on your capping machine with the seal's inner diameter, skirt height and aluminium thickness, plus its particle and cleanliness controls.
Give the supplier the vial size and neck finish, stopper type and drawing, seal type (plain, flip-off, tear-off), aluminium alloy and thickness, button colour, printing on skirt or top, capping machine and crimp settings, sterilisation or washing needs, cleanliness and particle limits, packaging and lot documentation.
02
West Pharmaceutical Services explains that the revised USP General Chapter <1> Injections, Labeling on Ferrules and Cap Overseals, effective 1 December 2013, limits what may be printed on the top surface of cap overseals and ferrules (aluminium shells) securing injectable drug vials sold in the United States. Only cautionary statements, meant to prevent an imminent life-threatening situation, may appear on the top (circle) surface, printed in a contrasting colour and clearly visible; identifying numbers or letters such as code numbers, lot numbers, company names, logos or product names may appear on the side (skirt) but not on the top. [2]
Editorial note: agree with the drug owner which statements, if any, appear on the top of the seal, and place lot or code marks on the skirt; ask the seal supplier for its printing capability and colour options.
03
West Pharmaceutical Services' note on Flip-Off seal cap removal testing explains that in an aluminium–plastic combination seal the plastic cap is moulded into the aluminium, and flipping it off breaks the thin aluminium bridges holding the centre disc (six bridges on its 13 mm and 20 mm seals), exposing the stopper; the broken bridges cannot be re-attached, which gives tamper evidence. [3]
The note lists conditions that can change the flip-off force after crimping: stopper bulging under the crimp, shrinkage of the metal seal in cryogenic storage, and simulated transport conditioning to ASTM D4169-22. Seals are factory-tested against ISO and/or YBB flip-off force specifications, but crimped and conditioned vials may need to show they still meet a minimum force so that caps do not come off in transport or storage. West validated its test with surrogate samples because the test destroys the sample. [3]
Editorial calculation: for a 20 mm seal the acceptance window under the Chinese standard is 6–35 N, a ratio of about 1 to 6; for a 13 mm seal it is 6–25 N.
| Requirement cited by West | 13 mm seal | 20 mm seal |
|---|---|---|
| ISO 8362-6: maximum cap removal force | 25 N | 35 N |
| YBB 00372003-2015: maximum cap removal force | 25 N | 35 N |
| YBB 00372003-2015: minimum flip-off force | 6 N | 6 N |
| ISO 8872 | Describes the removal-force test apparatus | Describes the removal-force test apparatus |
State the standard (ISO 8362-6 or YBB 00372003-2015), the force window, whether testing is on loose seals or on crimped, conditioned vials, and any cryogenic or transport conditioning.
04
Datwyler, which makes both vial stoppers and aluminium caps, describes the cap's job as securing the stopper against the vial finish and protecting the closure through processing, transport, storage and use, with the stopper forming the primary seal. Its cap range covers standard and PrimeCaps™ flip-off caps, total tear-off caps, centre tear-off caps and aluminium hole caps, in 13 mm, 20 mm and 32 mm formats for serum, lyophilisation and infusion vials. It lists 40 standard plastic colours and 5 standard aluminium colours, with inkjet printing, embossing and debossing on selected products. [4]
Components are offered ready-for-sterilisation (RFS), ready-to-use (RTU) or in Rapid Transfer Port (RTP) bags, with steam or gamma sterilisation options, and Datwyler states that they are made at eight sites in Europe, North America and Asia. For its PrimeCaps™, offered in selected 13 mm and 20 mm formats, it describes a centre-gated disc, rounded edges, a controlled opening-force design and a precision skirt edge intended for feeding, seating, crimping and inspection on high-speed lines. Datwyler states that cap selection should account for vial and stopper dimensions, crimping parameters, fill-finish equipment and opening performance, and that the drug manufacturer remains responsible for qualifying the components. [4]
Editorial note: printing options on the cap must still respect the USP <1> rule that only cautionary statements go on the top surface, with lot and code marks on the skirt; agree the flip-off force window against the ISO 8362-6 and YBB values above before choosing a design. [2] [3] [4]
| Choice | Options listed by Datwyler | Fix in the order |
|---|---|---|
| Cap type | Flip-off, total tear-off, centre tear-off, hole cap [4] | Type; opening method. |
| Size | 13 mm, 20 mm, 32 mm [4] | Match vial neck finish. |
| Colour | 40 plastic, 5 aluminium standard colours [4] | Colour code per product or strength. |
| Marking | Inkjet printing, embossing, debossing [4] | Text position (skirt or top). |
| Supply format | RFS, RTU, RTP; steam or gamma sterilisation [4] | Format for the filling line. |
05
| Part | Role | Fix in the order |
|---|---|---|
| Aluminium shell (skirt) | Crimped under vial rim. [1] | Inner diameter; height; thickness. |
| Top (annular portion) | Overlies stopper; printing area. [1] [2] | Opening; print. |
| Flip-off button | Exposes stopper. [1] | Colour; attachment. |
| Tear-off ring or tab | Opening or removal. [1] | Design. |
| Coating or lacquer | Surface protection. | Type. |
| Skirt markings | Lot and code marks. [2] | Print method. |
06
Thickness and tolerance rows decide whether the crimp takes up the ISO tolerance build-up of stopper and vial rim that the patent describes, so ask for both on the seal drawing. [1]
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Inner Diameter (mm) | Fits vial neck and stopper. [1] | Size; tolerance. |
| Flange Type | Flip-off, tear-off or plain. [1] | Design. |
| Material Grade | Malleable aluminium. [1] | Alloy; temper. |
| Thickness (mm) | Crimp behaviour. | Value. |
| Overall Height (mm) | Skirt length under rim. [1] | Value. |
| Tolerance (mm) | Matches ISO vial/stopper tolerances. [1] | Drawing. |
| Operating Temperature (°C) | Storage and sterilisation. | Range. |
| Surface Finish (μm) | Appearance; print. | Finish. |
| Weight (g) | Feeding. | Weight. |
| Packaging Quantity (pcs/bag) | Supply. | Quantity; bag type. |
| Flip-off force | ISO 8362-6 maximum 25 N (13 mm) / 35 N (20 mm); YBB minimum 6 N. [3] | Test results on crimped vials. |
07
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Vial: [size; neck finish] Stopper: [type; drawing] Seal: [plain; flip-off; tear-off] Material: [alloy; thickness] Printing: [top cautionary statement; skirt marks] Capping: [machine; crimp settings] Cleanliness: [particles; washing] Packaging: [bags; documentation]
2 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Its website has a product page for vial aluminium seals.
Product scope checked 2026-10-12
Its website has a product page for vial aluminium seals.
Product scope checked 2026-10-12
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
Its tubular skirt surrounds the stopper and vial rims and is crimped radially into the neck beneath the rim (US 6,382,442). [1]
Tearing aluminium caps creates sharp edges and metal particles; a plastic flip-off button reduces these problems (US 6,382,442). [1]
Under USP <1> (effective December 2013), only cautionary statements; lot numbers, logos and names go on the skirt (West). [2]
West cites ISO 8362-6 and YBB 00372003-2015: no more than 35 N for a 20 mm seal (25 N for 13 mm), and the Chinese standard also sets a 6 N minimum. [3]
Datwyler lists flip-off, tear-off and hole caps in 13, 20 and 32 mm, supplied ready-for-sterilisation, ready-to-use or in RTP bags, with steam or gamma sterilisation options. [4]
Sources checked 2026-10-12. The US patent describes conventional aluminium vial caps in its background; West summarises the USP <1> labelling standard and cap-removal testing; Datwyler describes its own cap and stopper range. USP text itself is not freely available.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.