Point level switches and level controllers for tanks · Float, vibration, capacitance, ultrasonic and optical switches, relay contact ratings, enclosure, pressure and temperature limits, fill/empty control and alarms
A level controller keeps liquid or solids in a tank between set levels: point level switches sense when the level reaches a set height, and a controller uses those signals to start or stop a pump or valve and raise alarms. Ask three things first: which switch technology suits the medium — buoyancy, vibration, capacitance, ultrasonic or optical; what the relay must switch, since a direct pump load needs a much higher rating than a pilot signal; and the pressure, temperature, material and enclosure the switch must survive.
Point level switches and level controllers for liquids and light bulk solids in tanks, sumps and silos — float, vibrating, capacitive, ultrasonic and optical — and controllers for automatic fill, empty and alarm duty. Continuous level transmitters, sight glasses and magnetic level indicators are covered on separate pages; vehicle coolant level switches are outside this page.
01
Flowline's liquid level switch range lists ultrasonic switches for chemicals, solvents and light oil, vibration switches for wastewater, capacitance switches for water and conductive chemicals, buoyancy switches for clean water and chemicals, optic leak switches for water and translucent chemicals, and multi-point switches up to 10 ft (3 m) long for day tanks, skids and sumps. They run on 12–36 VDC or 120/240 VAC with SPST or SPDT relay or reed contacts rated 15 VA (0.25 A), 60 VA (1 A) or 250 VAC at 16 A on the high-power models, in NEMA 4X (IP65) or NEMA 6 (IP68) housings of PP, PVDF, PFA or Ryton, rated −40 to 80 °C and atmospheric to 150 psi (10 bar) depending on the model. [1]
VEGA's capacitive VEGAPOINT switches cover water-based liquids, sticky and adhesive media and light bulk solids, with three-wire transistor output, IO-Link listed on the sticky-media, water-based (Ex/ship) and light-bulk-solids versions but not on the basic water-based version, ½ in threads with hygienic adapters, M12 or ISO 4400 connectors, a 360° illuminated status ring, and hygienic, Ex, ship or WHG approvals depending on the model. [3]
Editorial calculation: a 60 VA contact at 120 VAC carries 0.5 A and at 24 VDC 2.5 A, while a 16 A contact at 250 VAC is a 4,000 VA rating; compare these with the pump starter coil or motor current before wiring a load to the switch. [1]
Give the supplier the medium (liquid or solid, conductivity, viscosity, foam, build-up, density), tank type and mounting position, number of switch points and their heights, function (high or low alarm, fill, empty, shut-off), supply voltage and the load each contact switches, enclosure rating and cable or conduit, process connection, wetted materials, temperature and pressure, hazardous-area or hygienic approvals, and quantity.
02
Flowline's controllers for level switches take one to three switch inputs and provide automatic fill or empty control with high and/or low alarms (LC40-42, rail mount, one to three SPDT relays), a single high or low alarm (LC10, one SPDT relay) or automatic fill or empty from two switches (LC11, one SPDT latching relay), on 120/240 VAC in NEMA 1 or NEMA 4X housings, some with a strobe alert option. Its controllers for level transmitters add 6-digit or 3.5-digit displays and two to four SPDT relays on 85–265 VAC, 12–24 VDC or 120/240 VAC supplies. [2]
Editorial note: Flowline's two-switch LC11 uses a latching relay; ask any supplier how the pump starts and stops between the two switch points, the failsafe state of each relay on power loss, and how alarms are separated from control points.
03
Suppliers linked to this page list level switches or level controllers; each card links to the page reviewed.
Listings include capacitive and RF admittance level switches, tuning-fork and rotary-paddle switches for solids, ultrasonic level switches, water level controllers and refrigeration liquid level switches; ask each for the technology, contact rating, process connection, wetted materials and approvals.
04
Emerson's product data sheet for the Rosemount 2120 vibrating fork level switch gives, in water, a hysteresis of 0.1 in (2.5 mm) and a switching point 0.5 in (13 mm) from the fork tip when mounted vertically, or from the fork edge when mounted horizontally, and states that the switching point varies with liquid density. [4]
The data sheet sets a minimum liquid density of 600 kg/m³, a viscosity range up to 10,000 cP and a maximum recommended solid particle diameter of 5 mm, with bridging of the forks to be avoided. Switching delay is user-selectable at 0.3, 1, 3, 10 or 30 seconds for dry-to-wet and wet-to-dry switching, which Emerson presents as a guard against false switching from splashing in batch tanks with stirrers and agitators; the switching mode (dry = on or wet = on) is also selectable. Extended forks are listed up to 4,000 mm, and a magnetic test point lets the switch and the system connected to it be function-tested. [4]
Editorial note: these figures cover the switch-point and switching-delay rows that the other reviewed sources leave blank; ask any supplier for these values in your own liquid, since density and viscosity change them.
05
This is a functional reference built from the sources cited; it is not one maker's specification.
| Element | Role | Fix in the order |
|---|---|---|
| Sensing element | Float, fork, capacitance probe, ultrasonic gap or optic. [1] [3] | Technology for the medium. |
| Switch output | Relay, reed or transistor; IO-Link on some. [1] [3] | Contact form and rating. |
| Housing and seal | PP, PVDF, PFA; NEMA 4X to NEMA 6. [1] | Material, IP rating. |
| Process connection | 2 in or ¾ in NPT; ½ in thread with hygienic adapter. [1] [3] | Thread or flange. |
| Controller | Turns switch signals into pump and alarm control. [2] | Inputs, relays, mounting. |
06
A level controller quotation needs values for your application. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Measurement range (mm) | Multi-point switches up to 3 m. [1] | Length and switch heights. |
| Accuracy (%) | Not stated in reviewed sources. | Switch-point repeatability. |
| Operating temperature (°C) | −40 to 80 °C (Flowline). [1] | Range. |
| Output signal | SPST/SPDT relay or reed; transistor, IO-Link. [1] [3] | Output and rating. |
| Power supply (V DC/AC) | 12–36 VDC or 120/240 VAC. [1] [2] | Supply. |
| Process connection | 2 in or ¾ in NPT; ½ in thread. [1] [3] | Connection. |
| Enclosure rating | NEMA 4X (IP65) to NEMA 6 (IP68). [1] | Rating. |
| Material | PP, PVDF, PFA, Ryton. [1] | Wetted materials. |
| Weight (kg) | Not stated in reviewed sources. | Weight. |
| Response time (s) | Not stated in reviewed sources. | Switching delay. |
| Explosion protection | Ex-approved models available (VEGA). [3] | Approval and zone. |
07
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Medium: [liquid or solid; conductivity; viscosity; foam; build-up] Tank: [type; mounting position] Points: [number; heights; function] Outputs: [supply; loads switched; relay or transistor; IO-Link] Construction: [connection; materials; enclosure] Approvals: [Ex; hygienic; WHG] Controller: [fill/empty; alarms; mounting]
These companies list level switches or level controllers.
Lists capacitive and RF admittance level switches and level meters.
Product scope checked 2026-10-11
Lists level switches with industrial sensors.
Product scope checked 2026-10-11
Lists liquid level switches.
Product scope checked 2026-10-11
Lists level switches.
Product scope checked 2026-10-11
Lists level controllers with flow and level instruments.
Product scope checked 2026-10-11
Lists tuning-fork and rotary-paddle level switches and water level controllers.
Product scope checked 2026-10-11
Lists ultrasonic level switches and level control switches.
Product scope checked 2026-10-11
Lists liquid level switches for refrigeration systems.
Product scope checked 2026-10-11
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
Flowline lists vibration switches for wastewater and capacitance switches for water and conductive chemicals. [1]
Flowline's level-switch table lists 60 VA or 15 VA contacts on its multi-point and high/low switches, 60 VA (1 A) on its vibration, capacitance and optic leak switches, 15 VA (0.25 A) on its buoyancy switch, 32 VDC (0.5 A) on its ultrasonic switch, and SPDT relays rated 16 A at 250 VAC on its fill/empty and shut-off models. [1]
Flowline's controllers take one to three switch inputs and drive SPDT relays for fill or empty control and high or low alarms. [2]
Emerson's Rosemount 2120 data sheet offers a user-selectable switching delay of 0.3, 1, 3, 10 or 30 seconds for dry-to-wet and wet-to-dry switching. [4]
Sources checked 2026-10-11. Flowline and VEGA make level switches and controllers and describe their own ranges; ratings apply to the models listed.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.