A modular assembly of terminal blocks for connecting and distributing electrical wires within control panels.
Technical details and manufacturing context for Terminal Block Assembly
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Rated Current | 10–32 A | Continuous current per pole at 40°C ambientIEC 60947-7-1 |
| Rated Voltage | 400–1000 V | Rated insulation voltage (Ui)IEC 60947-7-1 |
| Wire Cross-Section | 0.5–35 mm² | Solid or stranded conductor rangeIEC 60947-7-1 |
| Number of Positions | 2–12 positions | Modular assembly, expandable |
| Rated Impulse Withstand Voltage | 6–8 kV | Uimp for overvoltage category IIIIEC 60947-1 |
| Pollution Degree | 3 | Industrial environmentIEC 60947-1 |
| Operating Temperature | -40–85 °C | Continuous operationIEC 60947-1 |
| Degree of Protection | IP20–IP65 | IP20 for open, IP65 with enclosureIEC 60529 |
| Tightening Torque | 0.5–2.5 N·m | For screw clampsIEC 60947-7-1 |
| Flammability Rating | V-0 | Housing materialUL 94 |
| Material | PA66 | Housing, glass-fiber reinforcedUL 94 |
| Weight per Position | 5–20 g | Approximate, varies with size |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
This component is essential for the following industrial systems and equipment:
| current: | Up to 300A per terminal (depends on conductor size and material) |
| voltage: | Up to 1000V AC/DC (depends on insulation and spacing) |
| ip rating: | IP20 (standard) to IP67 (with protective covers) |
| wire size: | 0.2 mm² to 300 mm² (AWG 24 to 500 MCM) |
| temperature: | -40°C to +105°C (operating range, varies by insulation material) |
| flammability rating: | UL94 V-0 or V-2 (material dependent) |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
Manufacturer profiles associated with Terminal Block Assembly.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The rated current per pole at 40°C ambient is 10 to 32 A, as per IEC 60947-7-1. However, this is a reference range; the exact value depends on the specific model and application. Always verify with the manufacturer's datasheet.
Yes, the assembly is designed to handle various circuit types, including power distribution, sensor signals, and control circuits. The modular design allows grouping of related circuits, but ensure that the rated voltage and current for each circuit are within the assembly's specifications.
The degree of protection is IP20 for open assemblies and IP65 when installed in an appropriate enclosure, according to IEC 60529. This means the assembly is protected against solid objects larger than 12.5 mm (IP20) and against dust and water jets (IP65) when enclosed.
The assembly references IEC 60947-7-1 for terminal blocks, IEC 60947-1 for general low-voltage switchgear, IEC 60529 for degrees of protection, and UL 94 for flammability. These standards are procurement references; compliance must be confirmed with the manufacturer for the specific product.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.