INDUSTRY COMPONENT

Tubing Connector

A precision medical tubing connector for contrast injectors, ensuring leak-free fluid transfer in diagnostic imaging systems.

Component Specifications

Definition
A specialized medical-grade connector designed to securely join tubing segments in contrast media injection systems, maintaining sterile fluid pathways while withstanding high-pressure injection cycles during CT, MRI, and angiography procedures. It features luer-lock or proprietary coupling mechanisms to prevent accidental disconnection.
Working Principle
Operates by creating a secure, pressure-resistant seal between tubing ends through mechanical locking (e.g., luer-lock threads) or compression fittings. The connector maintains fluid integrity by preventing leaks, backflow, or contamination during high-pressure contrast media delivery, typically at 300-1200 psi.
Materials
Medical-grade materials: Polycarbonate (body), Silicone or Polyurethane (seals), Stainless Steel 316L (locking components), BPA-free plastics. Biocompatible, sterilizable via autoclave (up to 134°C) or gamma irradiation.
Technical Parameters
  • Flow Rate 1-10 mL/s
  • Connection Type Luer-Lock (ISO 80369-7), Push-to-Connect
  • Leak Resistance Zero leakage at max rated pressure
  • Pressure Rating Up to 1200 psi (82.7 bar)
  • Temperature Range -20°C to 100°C
  • Tubing Compatibility 1/8" to 1/4" ID, various wall thicknesses
Standards
ISO 80369-7, ISO 594-1, ISO 594-2, DIN 13969, FDA 21 CFR Part 820

Industry Taxonomies & Aliases

Commonly used trade names and technical identifiers for Tubing Connector.

Parent Products

This component is used in the following industrial products

Engineering Analysis

Risks & Mitigation
  • Cross-contamination if not properly sterilized
  • Mechanical failure under cyclic pressure
  • Incompatibility causing fluid leakage
  • Material degradation from contrast media chemicals
FMEA Triads
Trigger: Seal material degradation from repeated sterilization
Failure: Fluid leakage during high-pressure injection
Mitigation: Use chemically resistant seals (e.g., FKM fluorocarbon) and implement replacement schedules based on cycle counts
Trigger: Improper connection torque
Failure: Thread stripping or incomplete seal
Mitigation: Train staff on proper hand-tightening techniques and use torque-limiting devices where specified
Trigger: Material incompatibility with contrast agents
Failure: Cracking or swelling of connector components
Mitigation: Verify chemical compatibility charts for specific contrast media (ionic/non-ionic) and connector materials

Industrial Ecosystem

Compatible With

Interchangeable Parts

Compliance & Inspection

Tolerance
Dimensional tolerance ±0.1 mm on critical sealing surfaces, pressure testing at 150% of rated pressure for 5 minutes
Test Method
Hydrostatic pressure testing per ISO 10555, leak testing with helium mass spectrometry, material biocompatibility per ISO 10993

Buyer Feedback

★★★★☆ 4.7 / 5.0 (14 reviews)

"Testing the Tubing Connector now; the technical reliability results are within 1% of the laboratory datasheet."

"Impressive build quality. Especially the technical reliability is very stable during long-term operation."

"As a professional in the Machinery and Equipment Manufacturing sector, I confirm this Tubing Connector meets all ISO standards."

Related Components

pH Sensor Assembly
Precision pH sensor assembly for automated monitoring and dosing systems in industrial applications
Load Cell Assembly
Precision load cell assembly for automated powder dispensing systems
Dust Collection Port
A dust collection port is a critical component in automated powder dispensing systems that captures airborne particulates at the source to maintain clean air quality and prevent cross-contamination.
Sensor Element
Core sensing component in industrial smart sensor modules that converts physical parameters into electrical signals for process monitoring and control.

Frequently Asked Questions

What sterilization methods are compatible with contrast injector tubing connectors?

Most connectors are compatible with autoclave sterilization (134°C, 2 bar), gamma irradiation (25-40 kGy), and ethylene oxide (EtO) sterilization. Always verify manufacturer specifications.

Are these connectors interchangeable between different contrast injector brands?

Not universally. While luer-lock connectors follow ISO standards, proprietary locking mechanisms (e.g., Bayer Medrad, Bracco Empower) require brand-specific connectors. Always check compatibility charts.

What causes connector failures in high-pressure applications?

Common failures include thread wear from repeated use, seal degradation from chemical exposure, and cracking from over-torquing. Regular inspection and replacement per manufacturer guidelines prevent failures.

Can I contact factories directly?

Yes, each factory profile provides direct contact information.