Editorial Technical Reference

Fluid Control Valve

This page explains how Fluid Control Valve is classified within Machinery and Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.

Technical Definition & Core Assembly

A precision valve designed to regulate, direct, or control the flow of fluids (liquids, gases, or medical solutions) within medical devices.

Product Specifications

Technical details and manufacturing context for Fluid Control Valve

Definition
This fluid control valve is a precision component used in medical device systems to manage the flow of liquids, gases, or medical solutions. It is designed to regulate flow rate, pressure, and direction with high accuracy, ensuring reliable operation in applications such as infusion pumps, dialysis machines, anesthesia delivery systems, and diagnostic equipment. The valve operates by opening, closing, or partially obstructing fluid passageways using mechanical, pneumatic, or electromechanical actuation. Common types include solenoid valves, pinch valves, check valves, and proportional valves, which respond to control signals to achieve precise flow regulation.

Typical technical parameters for this valve category include a nominal diameter of 2–50 mm (ISO 6708), an operating pressure range of 0.1–1.0 MPa, and a flow coefficient (Cv) of 0.01–5.0 (IEC 60534-2-3). Leakage rate is specified as ≤0.01% of rated Cv (ISO 5208, Class VI shutoff), and operating temperature ranges from -10°C to 80°C (ISO 5211). Response time is 10–50 ms (IEC 60534-4), control accuracy is ±1.0% of span (IEC 60534-4), and supply voltage is 24 V DC ±10% (IEC 61131-2). Power consumption is 2–10 W (IEC 60534-4), ingress protection is IP54–IP65 (IEC 60529), and weight ranges from 0.2–5.0 kg. Body material is typically 316L stainless steel (ASTM A240), and seal materials include PTFE/EPDM (ASTM D2000).

These values are directory reference ranges and must be verified for the specific model and application. Always confirm model-specific parameters and standards compliance with the legal manufacturer or supplier before procurement or use.
Working Principle
The valve regulates fluid flow by opening, closing, or partially obstructing the passageway. Actuation can be mechanical (manual or spring), pneumatic (air pressure), or electromechanical (solenoid or motor). The control signal, typically electrical, determines the valve position, allowing precise adjustment of flow rate and pressure. For proportional valves, the degree of opening is continuously variable, enabling fine control. Check valves allow flow in one direction only, preventing backflow. The valve's design ensures minimal leakage and fast response, critical for accurate dosing in medical applications.
Common Materials
Medical-grade stainless steel, PTFE (Polytetrafluoroethylene), Medical-grade plastics, Ceramic
Technical Parameters
ParameterTypical rangeNotes & selection driver
Nominal Diameter2–50 mmCommon sizes for medical fluid control.ISO 6708
Operating Pressure0.1–1.0 MPa
Flow Coefficient (Cv)0.01–5.0 CvDetermines flow capacity at given pressure drop.IEC 60534-2-3
Leakage Rate≤0.01 % of rated CvClass VI shutoff for bubble-tight sealing.ISO 5208
Operating Temperature-10–80 °COutside range may affect seal integrity.ISO 5211
Response Time10–50 msCritical for precise dosing in medical devices.IEC 60534-4
Control Accuracy±1.0 % of spanEnsures precise flow regulation.IEC 60534-4
Supply Voltage24 ±10% V DCStandard for medical device actuators.IEC 61131-2
Power Consumption2–10 WLow power for portable devices.IEC 60534-4
Ingress ProtectionIP54–IP65Protection against dust and water jets.IEC 60529
Body Material316L SSCorrosion-resistant for medical fluids.ASTM A240
Seal MaterialPTFE/EPDMChemical compatibility and temperature range.ASTM D2000
Weight0.2–5.0 kgAffects portability and mounting.

Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.

Components / BOM
  • Valve Body
    Main housing containing fluid pathways and connection ports
    Material: Medical-grade stainless steel
  • Seal/Diaphragm Part
    Creates fluid-tight closure to prevent leakage
    Material: PTFE or medical-grade elastomer
  • Actuator
    Mechanism that opens/closes the valve (solenoid, pneumatic, manual)
    Material: Stainless steel/copper/plastics
  • Spring Part
    Provides return force for valve closure in normally-closed designs
    Material: Stainless steel

Application & selection

Application Fit & Sizing Matrix

Operational Limits
pressure: 0 to 10 bar (150 psi)
flow rate: 0.1 to 50 L/min
temperature: -20°C to 120°C
slurry concentration: Not recommended for slurries above 5% solids by volume
Media Compatibility
✓ Sterile saline solutions ✓ Medical-grade gases (O2, N2) ✓ Contrast agents for imaging
Unsuitable: Corrosive chemicals or abrasive slurries
Sizing Data Required
  • Required flow rate (L/min)
  • System pressure differential (bar)
  • Fluid viscosity (cP)

Risk, maintenance & compliance

Reliability & Engineering Risk Analysis

Failure Mode & Root Cause
Cavitation damage
Cause: Rapid pressure drop below fluid vapor pressure causing bubble formation and implosion, eroding valve trim and body surfaces
Sticking or binding
Cause: Corrosion buildup, particulate contamination, or thermal expansion mismatch between components restricting movement
Maintenance Indicators
  • Unusual high-frequency vibration or whistling noise during operation
  • Visible external leakage at stem seals or body flanges with fluid accumulation
Engineering Tips
  • Install pressure gauges upstream and downstream to monitor and maintain operating pressure above cavitation limits
  • Implement routine flushing and filtration of process fluid to prevent particulate buildup and corrosion

Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.

Compliance & Manufacturing Standards

Applicable Standards
ISO 5208: Industrial valves - Pressure testing of valves ANSI/FCI 70-2: Control Valve Seat Leakage DIN EN 593: Industrial valves - Metallic butterfly valves

Quoted from the published standard.

Manufacturing Precision
  • Bore diameter: +/-0.05mm
  • Surface flatness: 0.08mm
Quality Inspection
  • Hydrostatic pressure test
  • Dimensional verification with CMM
Technical documentation
Request current drawings, revision history, and a signed specification sheet.
Manufacturing capability
Verify equipment lists, process limits, capacity, and representative production evidence.
Inspection readiness
Confirm test methods, calibrated equipment, sampling plans, and traceable reports.
Supplier transparency
Check the legal entity, factory address, ownership, certifications, and direct contacts.

Compare the published product scope and source details, then include your specifications and quantity in an enquiry.

Manufacturers of Fluid Control Valve

3 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.

XingYu Electron (Ningbo) Co.,Ltd.
Fenghua, Ningbo, Zhejiang (per official site), CN

The official stainless steel head angle seat valve page describes the angle seat design with high flow and low resistance, with pneumatic actuator, for on/off or control of liquids, gases and steam in food, beverage, pharmaceutical and chemical uses; the About page on the same domain describes a solenoid and solenoid valve manufacturer founded in 1991 with a 40,000 m² site in Fenghua, Ningbo and about 450 employees. Confirm size, pressure and temperature from the model datasheet.

Listed on the company's own website · profile compiled by CNFX from public sources
View source page ↗ xyelectron.com · recorded 2026-10-05
GEYA
Zhejiang, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “2Q Series fluid control valves”
View source page ↗ pneumaticmfg.com · recorded 2026-08-28
Hongmi Pneumatic Co., Ltd.
Wenzhou, Zhejiang, CN
Also makes: Pneumatic Cylinder, Solenoid Valve, Vacuum Pump and 2 more
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Fluid Control Valve (20)”
View source page ↗ homipneu.com · recorded 2026-09-17

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Buyer enquiry

Request manufacturing insight for Fluid Control Valve

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Frequently Asked Questions

What are the typical applications of this fluid control valve?

This valve is used in medical devices such as infusion pumps, dialysis machines, anesthesia delivery systems, and diagnostic equipment. It precisely manages fluid flow rates, pressure, and direction to ensure accurate dosing and patient safety.

What materials are commonly used for the valve body and seals?

Common body materials include medical-grade stainless steel (e.g., 316L) and medical-grade plastics. Seal materials often include PTFE (polytetrafluoroethylene) and EPDM. Ceramic may also be used for certain components. Always verify material compatibility with the specific fluid and application.

What standards should I check for this valve?

Relevant standards include ISO 6708 for nominal diameter, ISO 5208 for pressure and leakage, IEC 60534-2-3 for flow coefficient, IEC 60534-4 for response time and control accuracy, IEC 61131-2 for supply voltage, IEC 60529 for ingress protection, ASTM A240 for body material, and ASTM D2000 for seal material. Confirm compliance with the manufacturer.

How do I select the right valve for my medical device?

Consider required flow rate, pressure range, response time, control accuracy, and compatibility with the fluid. Review the technical parameters listed in the directory and verify them with the manufacturer for your specific application. Also consider environmental factors like temperature and ingress protection.

Related equipment

Applied To / Applications

This component is essential for the following industrial systems and equipment:

Industry Taxonomies & Aliases

Commonly used trade names and technical identifiers for Fluid Control Valve.

Data Basis

Editorial classification, named public sources where available, and source-reviewed manufacturer records.

Preliminary Technical Classification
This page supports structured research, RFQ preparation, and supplier evaluation. It does not replace buyer-led supplier qualification, standards review, or technical approval.

Need to Manufacture Fluid Control Valve?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Fluid Chamber
Next Product
Fluid Delivery System
Get QuotesChat