This page explains how Timer/Controller is classified within Machinery and Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
Electronic or electromechanical device that regulates the timing and sequence of cleaning cycles in industrial filtration systems.
Technical details and manufacturing context for Timer/Controller
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Supply Voltage | 24 ±10% V AC/DC | Outside this range the controller may malfunction.IEC 61131-2 |
| Power Consumption | 5–15 W | Depends on number of outputs active. |
| Number of Programs | 10–20 | Selectable via front panel. |
| Timing Range | 0.1–999 s | Adjustable in 0.1 s increments. |
| Timing Accuracy | ±0.05 % | At 25 °C ambient. |
| Number of Outputs | 4–16 | Each output can be independently programmed. |
| Output Rating | 250 V AC, 5 A | Resistive load; derate for inductive loads.IEC 60947-5-1 |
| Operating Temperature | -40–85 °C | Non-condensing.IEC 60068-2-1, IEC 60068-2-2 |
| Storage Temperature | -40–85 °C | Non-condensing.IEC 60068-2-1, IEC 60068-2-2 |
| Relative Humidity | 5–95 % RH | Non-condensing.IEC 60068-2-78 |
| Ingress Protection | IP54–IP65 | IP65 for washdown environments.IEC 60529 |
| Enclosure Material | ABS | Flame retardant grade.UL 94 HB |
| Weight | 0.5–1.5 kg | Depending on number of outputs. |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
This component is essential for the following industrial systems and equipment:
| pressure: | 0 to 10 bar |
| flow rate: | Up to 500 m³/h |
| temperature: | -20°C to +60°C |
| slurry concentration: | Up to 40% solids by weight |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
1 company lists this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
It regulates the timing, duration, and frequency of cleaning cycles in industrial filtration systems, such as shakers and pulse jet valves, to maintain filter performance by removing accumulated dust.
The supply voltage is 24 V AC/DC ±10% (per IEC 61131-2), and power consumption ranges from 5 to 15 W depending on the number of active outputs.
It typically has 4 to 16 outputs, each independently programmable, and 10 to 20 programs selectable via the front panel.
It operates and stores in -40 to 85 °C (non-condensing), with relative humidity 5–95% (non-condensing). Ingress protection is IP54–IP65, suitable for washdown environments.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.