Editorial Technical Reference

Motor starter

Low-voltage motor starters · Starting method, AC-3/AC-3e rating, overload trip class, short-circuit coordination type 1 or 2, and durability

A motor starter switches a three-phase induction motor on and off and protects it against overload and short circuit, built from a contactor and an overload relay, a manual motor starter (motor-protection circuit breaker), or both. Settle three things before ordering: the starting method and the motor's full-load current and efficiency class, the overload trip class and the short-circuit protective device with the coordination type it must achieve, and the control voltage, enclosure and durability for the duty.

Low-voltage direct-on-line, reversing and star-delta starters, magnetic (contactor-based) starters and manual motor starters for three-phase induction motors. Soft starters, variable-frequency drives, medium-voltage starters and engine (automotive or outboard) starter motors are outside this page; contactors and overload relays have their own pages.

CNFX editorial research · Sources checked October 11, 2026 · 7 sources

01

Size the starter to the motor, the duty and the starting method

ABB's motor protection and control catalogue lists starter solutions for direct-on-line, reversing and star-delta starting, built from contactors, thermal or electronic overload relays and manual motor starters. It notes that its MS116, MS132, MO132, MS165 and MO165 manual motor starters suit IE3 and IE4 motors of design N/H and NE/HE, and that NE/HE motors require utilization category AC-3e. Citing IEC 60034-12, it defines designs NE and HE as having higher locked-rotor current than designs N and H. [1]

Its MS132 range gives thermal and electromagnetic protection from 0.10 to 32 A, up to 15 kW at 400 V, in a 45 mm width, with a built-in disconnect function, temperature compensation, trip-free mechanism and lockable rotary handle. The ordering table runs from 0.03 kW (0.10–0.16 A) to 11 kW (20–25 A) and beyond, with short-circuit breaking capacity Ics of 100 kA at 400 V up to the 20 A size and 50 kA at 25 A. The technical data list rated voltage 690 V AC, trip class 10 (10A for MS116), mechanical durability of 100,000 cycles and electrical durability of 50,000–100,000 cycles depending on current. [1]

For small motors with high switching rates, the catalogue lists an electronic compact starter that combines direct-on-line, reversing, overload protection and emergency stop in a 22.5 mm wide device, rated for 30 million switching cycles for motors up to 3 kW at 400 V. [1]

Editorial calculation: in ABB's MS132 table a 4 kW, 400 V motor maps to the 6.3–10 A size and a 7.5 kW motor to the 10–16 A size; the setting is then made to the motor's nameplate full-load current, not to the kW figure. [1]

Give the supplier the motor power, voltage, frequency, nameplate full-load current, efficiency class and design (N/H or NE/HE), starting method (DOL, reversing, star-delta), starts per hour, overload trip class, prospective short-circuit current at the starter, protective device and required coordination type, control voltage, enclosure and IP rating, ambient temperature, standards and approvals, and quantity.

02

Set the short-circuit protection and coordination type

ABB's catalogue states that IEC/EN 60947-4-1 and UL 60947-4-1 define two types of coordination between the branch-circuit protective device and the motor starter. Under Type 1, in short-circuit conditions the contactor or starter does not endanger persons or installations but cannot operate again without repair or replacement of parts. Under Type 2 it does not endanger persons or installations and can operate afterwards; light welding of contacts is acceptable, and the maker must state the maintenance measures. [1]

The same section says complete coordination covers a selectivity test between the overload relay and the short-circuit protective device and short-circuit tests at a prospective current r that depends on the starter's AC-3/AC-3e rated current — for example 1 kA up to 16 A, 3 kA from 16 to 63 A and 5 kA from 63 to 125 A — and at the rated conditional short-circuit current Iq, for example 50 kA. [1]

For North American panels, the catalogue notes that NEC Article 409 requires industrial control panels to be marked with a short-circuit current rating, with UL 508A Supplement SB as an accepted method, and lists combination motor controller constructions: Type A fusible, Type C inverse-time breaker, Type D instantaneous-only breaker, Type E self-protected and Type F (manual motor starter plus contactor). [1]

Editorial note: a starter's own breaking capacity is not the coordination rating; ask for the tested combination (protective device, contactor and overload relay) with its coordination type and Iq at your voltage.

03

Compare what suppliers offer

Suppliers linked to this page list motor starters; each card links to the page reviewed.

The listings reviewed include contactor-based magnetic starters rated up to 690 V AC with AC-3 duty, an integrated star-delta starter, magnetic starters for circuits up to 550 V, and motor-protection circuit breakers rated 690 V up to 63 A. Ask each for the coordination tables, trip class and approvals of the exact combination quoted. [2] [4] [6] [3] [5] [7]

04

Trace what each part of the starter does

This is a functional reference built from the sources cited; it is not one maker's specification.

PartRoleFix in the order
ContactorSwitches the motor; AC-3/AC-3e rating. [1] [2]Rating; coil voltage.
Overload relayThermal or electronic overload; trip class. [1]Setting range; class.
Manual motor starterOverload, short-circuit and disconnect in one. [1]Range; Ics.
Short-circuit protective deviceFuse or breaker sized for coordination. [1]Device; type 1 or 2.
Star-delta or reversing setStarting method. [1] [2]Method; interlocks.
EnclosureProtection degree. [1]IP; mounting.

05

Fill the specification fields with values for your motor

A motor starter quotation needs values for your motor and supply. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.

FieldWhat it means and published valuesAsk the supplier for
Rated PowerMotor kW at 400 V, e.g. up to 15 kW for MS132. [1]Rating at your voltage.
Rated VoltageUe 690 V AC example. [1]Ue; frequency.
Rated CurrentSetting range, e.g. 0.10–32 A. [1]Range covering nameplate FLC.
Breaking CapacityIcs 100 kA at 400 V up to 20 A (MS132). [1]Ics; coordination Iq.
Mechanical Endurance100,000 cycles (MS116/MS132). [1]Cycles.
Electrical Endurance50,000–100,000 cycles by current; 30 million for electronic compact starter. [1]Cycles at your duty.
Operating TemperatureTemperature compensated up to 60 °C. [1]Range; derating.
Degree of ProtectionEnclosure IP rating. [1]IP rating.
Coil VoltageContactor control voltage. [1]AC or DC; value.
Coil Power ConsumptionControl circuit load.Pull-in and holding VA/W.
Weight0.215–0.310 kg (MS132 sizes listed). [1]Weight.
Dimensions (HxWxD)45 mm width (MS132); 22.5 mm (electronic compact). [1]Dimensions.

06

Send the motor, supply and protection data together

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Motor: [kW; V; Hz; FLC; IE class; design N/H/NE/HE]
Starting: [DOL; reversing; star-delta; starts/hour]
Overload: [trip class; thermal or electronic]
Short circuit: [prospective kA; fuse or breaker; Type 1 or 2]
Control: [coil voltage AC/DC]
Enclosure: [IP; mounting]
Approvals: [IEC; UL; other]
Quantity: [units]

See manufacturer records Send an enquiry through CNFX

Compare motor starter suppliers

These companies list motor starters.

CNC Electric
Manufacturing site to be confirmed for the order

Lists LE1 magnetic starters for circuits up to 690 V AC with AC-3 duty, and an integrated star-delta starter.

Product scope checked 2026-10-11

Current product source ↗

Magnetic starters listed · profile compiled by CNFX from public sources
YUANKY Electric
Manufacturing site to be confirmed for the order

Lists Q7, QCX2 and QCX5 series magnetic starters.

Product scope checked 2026-10-11

Current product source ↗

Magnetic starters listed · profile compiled by CNFX from public sources
YUEQING WINSTON ELECTRIC CO.,LTD
Manufacturing site to be confirmed for the order

Lists magnetic starters for circuits up to 550 V.

Product scope checked 2026-10-11

Current product source ↗

Magnetic starters listed · profile compiled by CNFX from public sources
SEL Electric
Manufacturing site to be confirmed for the order

Lists contactors, relays and starters.

Product scope checked 2026-10-11

Current product source ↗

Starters listed · profile compiled by CNFX from public sources
HIITIO
Manufacturing site to be confirmed for the order

Lists 690 V motor-protection circuit breakers (UL manual motor starters) up to 63 A.

Product scope checked 2026-10-11

Current product source ↗

Manual motor starters listed · profile compiled by CNFX from public sources
Zhejiang KRIPAL Electric Co., Ltd.
Manufacturing site to be confirmed for the order

Lists magnetic starters.

Product scope checked 2026-10-11

Current product source ↗

Magnetic starters listed · profile compiled by CNFX from public sources

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

What is the difference between Type 1 and Type 2 coordination?

Per ABB's summary of IEC 60947-4-1, both keep people and installations safe; after a short circuit a Type 1 starter needs repair, while a Type 2 starter can operate again (light contact welding allowed). [1]

What is AC-3e?

ABB says IE3/IE4 motors of design NE/HE, which have higher locked-rotor current, require utilization category AC-3e. [1]

What trip class does a manual motor starter have?

ABB lists trip class 10 for MS132 and MS165 and 10A for MS116. [1]

What breaking capacity do manual motor starters have?

ABB's MS132 lists Ics of 100 kA at 400 V up to 20 A and 50 kA at 25 A. [1]

Sources and what still needs a direct check

Sources checked 2026-10-11. ABB's motor protection and control catalogue gives the IEC/UL coordination definitions, AC-3e requirement and manual motor starter data; the rest are linked suppliers.

  1. ABB — Motor protection and control catalogue (1SBC100214C0202, 03/2024) ↗ Maker catalogue Return to text ↑
  2. CNC Electric — Magnetic starter ↗ Supplier product page Return to text ↑
  3. YUANKY — Magnetic starter ↗ Supplier product page Return to text ↑
  4. Winston — Magnetic starter ↗ Supplier product page Return to text ↑
  5. SEL Electric — Contactor, relay, starter and frequency inverter ↗ Supplier product page Return to text ↑
  6. HIITIO — Motor protection circuit breakers (UL) ↗ Supplier product page Return to text ↑
  7. KRIPAL — Products ↗ Supplier website Return to text ↑

Still to check yourself

  • Match starter to motor FLC and design.
  • Fix trip class.
  • Confirm tested coordination type and Iq.
  • Set control voltage and enclosure.
  • Verify the legal supplier and maker.
Buyer enquiry

Request manufacturing insight for Motor Starter

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Motor Starter?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Motor Controller
Next Product
Motor Terminal Block
Get QuotesChat