This page explains how Quality Control Station is classified within Motor Vehicle Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
A dedicated inspection and testing station within an automotive assembly line for verifying chassis component quality and assembly accuracy.
Technical details and manufacturing context for Quality Control Station
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Test Force Range | 5–50 kN | Covers chassis component loads |
| Positioning Accuracy | ±0.05 mm | Ensures assembly alignmentISO 230-2 |
| Measurement Resolution | 0.001 mm | For high-precision inspection |
| Cycle Time | 30–60 s | Matches line speed |
| Supply Voltage | 24 ±10% V DC | For sensors and controlsIEC 61131-2 |
| Power Consumption | 0.5–2.0 kW | Includes PLC and actuators |
| Operating Temperature | 0–50 °C | Outside range affects sensor accuracyIEC 60068-2-1/2 |
| Humidity Range | 20–80 % RH | Non-condensingIEC 60068-2-78 |
| Ingress Protection | IP54–IP65 | Dust and water resistanceIEC 60529 |
| Frame Material | S355JR | Structural steel for rigidityEN 10025-2 |
| Weight | 800–1500 kg | Depends on options |
| Footprint | 2.5–4.0 m² | Compact for line integration |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
| pressure: | Atmospheric only (non-pressurized system) |
| other spec: | Vibration tolerance: ≤2.5 mm/s RMS, Humidity: 30-70% RH non-condensing, Power: 110-240V AC, 50/60Hz |
| temperature: | 15-35°C (operating), -10 to 50°C (storage) |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
Manufacturer profiles associated with Quality Control Station.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The station is used to inspect and test assembled chassis components to ensure they meet quality standards, dimensional tolerances, and functional requirements before further assembly.
Calibrated tools such as calipers, gauges, CMM, vision systems, and functional testers are used to check critical dimensions, weld integrity, alignment, and mechanical properties.
The station operates in temperatures from 0 to 50 °C and humidity from 20% to 80% RH non-condensing. Deviations may affect sensor accuracy.
All inspection results are logged in a traceability system, allowing for process control and quality assurance throughout the assembly line.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.