LED underground (in-ground) lights · EN 60598-2-13 installation areas, static load, protrusion and glass surface temperature, IP68 sealing, stainless housing, beam angle, low-voltage supply and dimming
An LED underground light, also called an in-ground or recessed ground luminaire, is a sealed fitting set into paving, soil or decking with its glass flush or nearly flush with the surface, an LED module, optic, heat-sinking body and watertight cable entry, used to uplight façades, trees and paths or to mark walkways and driveways. Ask three things first: which installation area it will sit in and what load and glass temperature that demands, how it is sealed against water and drained, and what beam, power supply and control it uses.
LED luminaires recessed into the ground or deck: round and square in-ground uplights, marker lights and drive-over fittings. General landscape luminaires such as spike, bollard and garden lights (see LED landscape lighting), underwater pool lights and street lighting are outside this page.
01
Performance in Lighting's summary of EN 60598-2-13 says the standard defines where in-ground luminaires may be installed according to static load, protrusion of the diffuser above the ground and diffuser temperature. It lists A1 no-touch areas with no limits; A2 walk-over areas at ≥5 kN, ≤5 or ≤25 mm protrusion and ≤100 °C; A3 motorable areas at ≥20 kN, ≤75 mm and ≤80 °C; A4 areas reached by snowploughs or anti-freeze agents at ≥20 kN, ≤5 or ≤25 mm and ≤80 °C; and A5 touch walk-over areas such as children's areas and swimming pools at ≥5 kN and ≤40 °C. [1]
Editorial calculation: a static load of 5 kN equals about 510 kgf and 20 kN about 2,040 kgf (dividing by 9.81 m/s²); ask the supplier for the tested static load in kN and the installation area code rather than a vehicle description. [1]
The scope of the standard itself, as published in the Gulf adoption GSO IEC 60598-2-13:2015, covers ground recessed luminaires with electric light sources for supply voltages up to 1 000 V, for indoor or outdoor use in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pool areas outside the zones for SELV, nurseries and similar applications. It does not cover ground recessed luminaires for motorised roads and for airfields, which are specified in IEC 61827. [4] Editorial note: a fitting rated for the motorable area A3 in the summary above is therefore tested for driveways and car parks within this scope; a fitting set into a public road or a runway falls under other requirements, so state the exact location when asking for the rating. [1] [4]
Editorial note: the summary above is one manufacturer's reading of the standard; check the current EN or IEC 60598-2-13 text and the supplier's test report for the exact limits and test conditions.
Give the supplier the installation area (planting bed, walkway, driveway, play area, pool deck), static load needed, permitted protrusion, glass temperature limit, substrate and drainage, target (façade, tree, path), beam angle, lumens, CCT or RGB, supply voltage and driver location, dimming or DMX control, cable length and gland, finish and material, and quantities.
02
Chongqing Xinyuanhui lists LED underground lights with 304 stainless steel bodies, transparent tempered glass, a waterproof plug and IP68 sealing; the specification table on that page (item XYH159GM) gives 18 or 36 W at 24 V, Φ159 × 54.5 mm, SS304 or SS316, 2700–6500 K or RGB, 15°, 30°, 45° or 60° beams, at least 50,000 h life, a 2-year warranty and 0–10 V, DALI, TRIAC or DMX512 dimming. [2]
The same table is headed as an underwater pool light, so confirm with the supplier which model the values belong to before ordering. [2]
Editorial note: IP68 depth and duration are set by the maker; ask for the test depth and time, how the cable gland is sealed, how condensation is prevented, and whether the glass temperature was measured at the area limit that applies.
iGuzzini's Light Up Orbit flush-mounted in-ground luminaire shows how a maker states load and sealing. It lists an AISI 304 stainless steel body and frame flush with the floor, hardened safety glass, an A2 stainless cable gland with a 2 × 1 mm² cable and an IP68 anti-transpiration device, and a polypropylene installation casing with a stainless ring ordered separately. It is powered at constant current of 350, 500 or 700 mA from a separately ordered safety extra-low-voltage supply, is Class III with IP66, IP68 and IP68 10 m ratings and IK07 or IK09 impact ratings, and has a static load resistance of 2,000 kg when installed with the casing. iGuzzini states it is a roll-over product to EN 60598-2-13 (torsion strength and shear load tests), that it cannot be used in lanes where acceleration, braking or changes of direction apply horizontal stress, and that it is not suitable for swimming pools or fountains. [3]
Editorial calculation: 2,000 kg × 9.81 m/s² ≈ 19.6 kN, just below the ≥20 kN that the Performance in Lighting summary gives for A3 motorable areas, so a 2,000 kg rating should be checked against the area code the supplier actually tested to rather than assumed to be drive-over in every sense. [3] [1]
03
Suppliers linked to this page list LED underground lights; each card links to the page reviewed.
Listings include stainless steel in-ground lights from 3 W upward, mini RGB fittings and inground landscape lights with tempered glass.
04
This is a functional reference built from the sources cited; it is not one maker's design.
| Part | Role | Fix in the order |
|---|---|---|
| LED module | Produces light. [2] | Power, CCT, RGB. |
| Optic | Sets the beam. [2] | 15–60° options. |
| Glass cover | Carries load, limits heat. [1] [2] | Tempered glass, load, temperature. |
| Body and trim | Seals and resists corrosion. [2] | SS304 or SS316. |
| Gasket and cable gland | Keep water out. [2] | IP68 depth, plug. |
| Driver | Supplies 24 V and dimming. [2] | Location, protocol. |
| Installation sleeve | Fixes in the ground; carries load rating. [3] | Sleeve and drainage. |
| Supply rating | Within the standard's scope up to 1 000 V supply. [4] | Mains or SELV; driver location. |
05
An LED underground light quotation needs values for your site. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Power Rating (watts) | 18 or 36 W in one listing. [2] | Input power. |
| Luminous Flux (lumens) | Light output. | Measured lumens. |
| Color Temperature (kelvin) | 2700–6500 K or RGB in one listing. [2] | CCT. |
| Ingress Protection Rating (IP code) | IP68 in one listing; IP68 10 m in another. [2] [3] | Test depth and time. |
| Operating Voltage (volts) | 24 V in one listing; 350/500/700 mA constant current in another. [2] [3] | Supply and driver. |
| Beam Angle (degrees) | 15°, 30°, 45° or 60° in one listing. [2] | Photometric file. |
| Operating Temperature (°C) | Glass ≤100 °C walk-over, ≤80 °C motorable, ≤40 °C touch areas. [1] | Glass temperature test. |
| Housing Material | SS304 or SS316 in one listing. [2] | Grade and finish. |
| Lens Material | Tempered glass in one listing. [2] | Glass thickness. |
| Impact Resistance | Static load ≥5 kN walk-over, ≥20 kN motorable; 2,000 kg and IK07/IK09 in one product. [1] [3] | Tested load and area code. |
| Cable Length (m) | Connection to driver. | Length and gland. |
| Weight (kg) | Installation. | Weight. |
06
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Area: [walkway; driveway; play area; pool deck; load kN] Light: [watts; lumens; CCT or RGB; beam] Sealing: [IP68 depth; gland; drainage] Supply: [24 V; driver location; DALI; DMX] Build: [SS304 or SS316; glass; sleeve] Supply: [test reports; quantity]
These companies list LED underground lights.
Lists stainless steel IP68 LED underground lights with tempered glass, 24 V supply and DALI or DMX dimming options.
Product scope checked 2026-10-11
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
One maker's summary of EN 60598-2-13 gives a static load of at least 20 kN and a glass temperature of at most 80 °C for motorable areas. [1]
The same summary gives at most 40 °C for touch walk-over areas such as children's areas and swimming pools. [1]
One supplier lists SS304 or SS316, tempered glass, IP68, 24 V, 18 or 36 W and 15–60° beams with DALI or DMX dimming. [2]
Not where vehicles brake, accelerate or turn over it: iGuzzini states its 2,000 kg-rated Light Up Orbit cannot be used in lanes with horizontal stress from acceleration, braking or changes of direction. [3]
Not under IEC 60598-2-13 alone: its scope, as published in GSO IEC 60598-2-13:2015, excludes ground recessed luminaires for motorised roads and airfields, which are covered by IEC 61827; carriageways, parking lots, footways and pool areas outside SELV zones are within scope. [4]
Sources checked 2026-10-11. Performance in Lighting summarises the EN 60598-2-13 installation areas; the GSO scope page gives the standard's own coverage; Chongqing Xinyuanhui and iGuzzini describe their own products. Limits for your site must come from the current standard text and the supplier's test reports.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.