LED tube lamps (TLEDs) replacing T5 and T8 fluorescent tubes · UL Type A ballast-compatible, Type B ballast-bypass, Type C external driver and hybrids, socket and wiring configuration, light output and distribution, efficacy
LED tube lights are linear LED lamps made in the T8 and T5 form factors to replace fluorescent tubes in existing fixtures. Ask three things first: which installation type suits the fixtures (keep the ballast, bypass it, or use an external driver), which socket and wiring configuration the lamp needs, and whether its light output and distribution will match the fluorescent lamps it replaces in your fixtures.
Linear LED tube lamps in T8 and T5 sizes (UL Types A, B, C and hybrid) for retrofitting fluorescent luminaires. Dedicated LED linear luminaires, LED troffer retrofit kits, LED strip lights and fluorescent ballasts are outside this page except where compared.
01
A presentation hosted by the US Department of Energy (TLED workshop, Denver 2016) classifies tubular LED lamps as plug-and-play, ballast-compatible UL Type A; integrated-driver, ballast-bypass UL Type B; external-driver UL Type C; and hybrids that are Type A and Type B. It notes that Type A lamps are not all equally ballast-compatible, since ballasts may be instant-start, programmed-start, dimming or emergency types, change from batch to batch and are discontinued; that Type A dimming has limited compatibility and range; that Type B lamps bypass the ballast, with single-ended designs needing at least one non-shunted lampholder per lamp and double-ended designs able to use the shunted lampholders of instant-start fixtures; and that converting a hybrid from Type A to Type B requires warning labels to be installed in the modified fixture. [2]
Editorial note: give the supplier the existing ballast make and model for Type A lamps and ask for the lamp's ballast compatibility list; for Type B, confirm whether the lamp is single- or double-ended and which lampholders it needs, and plan the fixture relabelling.
Give the supplier the existing fixtures and ballasts (make, model, type), lamp length and form factor (T8, T5), preferred type (A, B, C, hybrid), socket type (shunted or non-shunted), required lumen output and CCT/CRI, dimming or emergency needs, voltage, operating temperature, certifications, and warranty.
02
DOE's CALiPER Application Summary Report 21 (March 2014) tested 31 linear LED lamps sold as alternatives to T8 fluorescent lamps to IES LM-79-08. Mean efficacy was similar to that of fluorescent lamps, but more than half of the products gave under 2,000 lm against about 3,000 lm for a 32 W fluorescent T8 lamp, and every lamp's luminous intensity distribution was directional or semi-directional rather than omnidirectional, which changes performance in the fixture. Lamps with diffuse optics averaged 90 lm/W (66–105 lm/W) and those with clear optics 101 lm/W (79–143 lm/W), diffusion reducing efficacy by about 10% on average. [1]
The report explains that instant-start ballasts use shunted lampholders and rapid-start and magnetic ballasts use unshunted ones, that linear LED lamps may be wired at one or both ends and need shunted, unshunted or no existing sockets, and that improper wiring can cause failure or dangerous conditions such as sparking, smoking or tripped breakers; it identified seven wiring configurations among the tested lamps. [1]
Editorial calculation: 101 / 90 ≈ 1.12, so in that 2014 sample the clear-optic lamps averaged about 12% higher efficacy than diffuse ones; products have changed since, so ask the supplier for LM-79 test reports of the exact lamp, in your fixture where possible. [1]
A current maker sheet gives the figures to ask for. TCP's LED Pro Line T8 spec sheet lists a 12 W, 4 ft Type A glass tube for instant-start ballasts drawing 14.9 system watts and giving 1,800 lumens (120.8 lm/W) at normal ballast factor, and a 13.5 W Type B ballast-bypass tube giving 1,800 lumens at line voltage (140.7 lm/W). Both are rated CRI 80, 50,000 hours, power factor 0.99, 120–277 V, G13 base, −20 °C minimum starting and 45 °C maximum operating temperature, 190° beam angle, and a 47.8 in length for the 4 ft tube; THD is under 8% at 120 V, ballast dependent. The sheet adds a list of instant-start ballast models tested with its Type A tube and notes that field conditions may differ from lab compatibility tests. [3]
Editorial calculation: on that sheet, removing the ballast (Type B) cuts system power from 14.9 W to 13.5 W for the same 1,800 lumens, about 9% less (1 − 13.5 ÷ 14.9), against the 32 W fluorescent lamp both are rated to replace. [3]
For rebate eligibility, the DesignLights Consortium's SSL Technical Requirements Tables V5.1 (effective 1 July 2020) set bare-lamp minimums for linear replacement lamps of 1,600 lm for 4 ft T8 and T5 lamps, 800 lm for 2 ft T8, 1,200 lm for 3 ft T8, 3,200 lm for 4 ft T5HO and 8 ft T8, and 1,400 lm for U-bend lamps, each at a minimum efficacy of 120 lm/W. The category covers both direct replacements and tubes that need ballast bypass, is limited to the DLC Standard classification, and from V5.1 is verified on bare-lamp performance only. [4] Editorial calculation: the 12 W, 1,800 lm TCP tube above is 150 lm/W at the lamp, but 1,800 lm over the 14.9 W Type A system watts is about 121 lm/W and over 13.5 W Type B about 133 lm/W; ask suppliers whether quoted efficacy is lamp-only or includes the ballast, and for the DLC listing if a rebate depends on it. [4] [3]
03
This is a functional reference built from the sources cited; it is not one maker's design.
| Part | Role | Fix in the order |
|---|---|---|
| LED board | Produces light. [1] | Efficacy; CCT; CRI. |
| Optic (clear or diffuse) | Sets distribution and efficacy. [1] | Clear or diffuse. |
| Driver (integral or external) | Powers LEDs. [2] | Type A, B or C. |
| End caps and pins | Fit lampholders. [1] [2] | Single or double ended. |
| Ballast interface | Type A operation. [2] | Compatibility list. |
| Labels | Mark modified fixtures. [2] | Warning labels. |
04
An LED tube quotation needs values for your fixtures. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Luminous Flux (lumens) | Lower than fluorescent in 2014 tests; 1,800 lm for one current 4 ft tube; DLC minimum 1,600 lm for 4 ft. [1] [3] [4] | LM-79 lumens. |
| Power Consumption (watts) | Lamp and ballast watts for Type A; e.g. 14.9 W system (A), 13.5 W (B). [2] [3] | System watts. |
| Color Temperature (Kelvin) | Office and classroom use. [1] | CCT. |
| Color Rendering Index (Ra) | Colour quality; e.g. CRI 80. [3] | CRI. |
| Tube Length (millimeters) | T8 or T5 length; e.g. 47.8 in for 4 ft. [3] | Length; caps. |
| Lifespan (hours) | Lumen maintenance; e.g. 50,000 h rated. [3] | LM-80/TM-21 data. |
| Input Voltage (volts) | Line or ballast output. [2] | Range. |
| Beam Angle (°) | Directional or semi-directional. [1] | Distribution file. |
| Power Factor | Supply quality; e.g. 0.99, THD <8%. [3] | Value. |
| Operating Temperature (°C) | Fixture environment; e.g. −20 °C start, 45 °C max. [3] | Range. |
| IP Rating | Damp or wet use. | Rating. |
| Weight (kg) | Handling. | Weight. |
05
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Fixtures: [type; count; lamp per fixture] Ballasts: [make; model; type] Lamp: [T8 or T5; length] Type: [A; B; C; hybrid] Sockets: [shunted; non-shunted] Light: [lumens; CCT; CRI; distribution] Controls: [dimming; emergency] Documents: [LM-79; compatibility list; certification]
This company lists this product on its own website.
Lists T8 LED tube lights in 0.6, 0.9, 1.2 and 1.5 m lengths from 10 W to 22 W, in normal and all-in-one types with isolated drivers.
Product scope checked 2026-10-12
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
Type A runs on the existing ballast, Type B is wired to line voltage bypassing the ballast, and Type C uses an external driver; hybrids do A and B (DOE-hosted TLED presentation). [2]
Not always; DOE's CALiPER tests found more than half under 2,000 lm (vs about 3,000 lm for an F32T8) and distributions directional or semi-directional. [1]
Lamps may need shunted, unshunted or no existing sockets, and wrong wiring can cause sparking, smoking or tripped breakers (CALiPER Report 21). [1]
TCP's LED Pro Line T8 sheet lists 14.9 system watts for its 12 W Type A tube on a ballast and 13.5 W for its Type B tube on line voltage, both giving 1,800 lumens. [3]
Under DLC V5.1, a 4 ft T8 linear replacement lamp needs at least 1,600 lm and 120 lm/W measured on the bare lamp. [4]
Sources checked 2026-10-12. Both sources are DOE-hosted: CALiPER test results from 2014 and a 2016 workshop presentation; products have changed since, so check current test reports.