This page explains how Air Handling Unit is classified within Machinery and Equipment Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
A device that conditions and circulates air as part of a heating, ventilation, and air conditioning (HVAC) system
Technical details and manufacturing context for Air Handling Unit
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Air Flow RateRequired | 2000–60000 m³/h | Maximum air handling capacityISO 5801 |
| Static PressureRequired | 300–2000 Pa | Pressure developed by the fan to overcome system resistanceISO 5801 |
| Filtration EfficiencyRequired | G4–F9 % | Particle removal efficiency of HEPA filtersEN 779 |
| Temperature Control RangeRequired | 10–40 °C | Range of temperature control capability |
| Humidity Control RangeRequired | 30–80 %RH | Range of relative humidity control capability |
| Cooling Capacity | 10–500 kW | Matches heat load.ISO 5151 |
| Heating Capacity | 10–600 kW | For winter operation.ISO 5151 |
| Power Supply | 380/3/50 V/Ph/Hz | Other voltages available.IEC 60038 |
| Noise Level | 55–75 dB(A) | Lower for indoor installation.ISO 3744 |
| Operating Temperature | -10–50 °C | Ambient conditions. |
| Ingress Protection | IP54–IP65 | Higher for outdoor use.IEC 60529 |
| Weight | 200–5000 kg | Depends on size and configuration. |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
Commonly used trade names and technical identifiers for Air Handling Unit.
This component is essential for the following industrial systems and equipment:
| pressure: | Up to 2500 Pa static pressure (typical range) |
| flow rate: | 500 to 50,000 CFM (cubic feet per minute) |
| other spec: | Humidity range: 0-95% RH non-condensing |
| temperature: | -20°C to 80°C (operating range, varies by model) |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
6 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The AHU provides conditioned, filtered air to maintain precise temperature, humidity, and cleanliness in the coating chamber, ensuring consistent coating quality and compliance with pharmaceutical standards.
Verify air flow rate, static pressure, filtration efficiency, temperature and humidity control ranges, cooling/heating capacity, power supply, noise level, operating temperature and pressure, ingress protection, and weight. These must match the system requirements and be confirmed with the manufacturer.
Standards include ISO 5801 for air flow and static pressure, EN 779 for filtration, ISO 5151 for cooling/heating capacity, IEC 60038 for power supply, ISO 3744 for noise, and IEC 60529 for ingress protection. These are references for verification, not certification.
Regular maintenance includes inspecting and replacing filters, cleaning coils and drain pans, checking fan operation and belt tension, verifying damper and valve function, and monitoring pressure drops and air quality. Follow the manufacturer's schedule.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.