Electric power fittings (overhead line hardware)

Overhead line fittings (power line hardware) that hold conductors to insulators and towers: suspension clamps, clevises, shackles, yoke plates and similar parts · Conductor diameter range, ultimate and slip load, line angle, conductor temperature, materials and finish, dimensions and pin size

Electric power fittings are the metal parts that hang, hold and join overhead conductors: suspension and tension clamps, clevises, shackles, yoke plates and links between the conductor, the insulator string and the tower or pole. Each part carries mechanical load in all weather for decades. Ask three things first: which conductor and size the fitting must hold, what mechanical load and line angle it must carry, and what materials, finish and interfaces the line design specifies.

Fittings for overhead transmission and distribution lines, with suspension clamps as the worked example, and made-to-drawing clevises, shackles, yoke plates and brackets. Insulators (see high-voltage insulator), bushings, conductors and cable terminations (see high-voltage insulated cable termination) are outside this page.

CNFX editorial research · Sources checked October 12, 2026 · 4 sources

Electric Power Fitting in a manufacturing environment
Representative product image. Confirm appearance and specifications with the manufacturer.

01

Match the conductor range, ultimate load and line angle

Preformed Line Products lists its Aluminum Suspension (ALS) clamps for all aluminium-based conductors in six sizes: ALS-47 for 5.1–11.9 mm conductors at 5,000 lbf vertical ultimate load, ALS-67 for 11.9–17 mm at 10,000 lbf, ALS-91 for 17–23.1 mm at 15,000 lbf, and ALS-122, -181 and -236 for 23.1–60 mm at 25,000 lbf, the largest three designed for EHV use. The maximum recommended line angle is 30° as a single suspension and 60° in a double configuration with a yoke plate and clevis eyes. [1]

Hubbell's Anderson HAS85N suspension clamp lists a clamping range of 0.4–0.85 inch, compatibility with aluminium stranded conductors from 2/0 AWG to 550 kcmil and ACSR from 1/0 AWG to 477 kcmil, a maximum take-off angle of 30°, ultimate body strength of 18,000 lb and a recommended bolt installation torque of 480 in-lb. [2]

Editorial calculation: 5,000 lbf is about 22.2 kN and 25,000 lbf about 111 kN (× 4.448 N per lbf); 18,000 lb is about 80 kN. [1] [2]

Give the supplier the conductor type, size and diameter, armour rods if used, design and ultimate loads (vertical and longitudinal), line angle, single or double suspension, conductor operating and emergency temperature, interface to the insulator string (clevis, eye, ball or socket), pin or bolt size, material and finish, and whether parts are catalogue items or made to your drawing.

02

Check temperature rating, materials, hardware and interfaces

The ALS clamp has an aluminium alloy body and keeper, galvanised steel hardware and a stainless steel cotter pin, is shipped assembled with factory-installed fasteners, and is designed for continuous conductor temperatures up to 125 °C, or 150 °C for two-hour emergencies. PLP recommends armour rods over the conductor at suspension points to reduce static and dynamic stresses at the clamp ends, and lists a 5/8 inch (15.9 mm) clevis pin on all sizes. [1]

JK Casting describes made-to-drawing power line fittings and pole line hardware, such as clevises, shackles, yoke plates, clamp bodies, brackets and guy-wire fittings, cast by investment or resin-sand casting in carbon steel, ductile iron or grey iron and supplied raw or CNC-machined and galvanised as specified. [3]

Editorial note: for made-to-drawing fittings, the drawing, material grade, galvanising and type tests define the part; ask for test reports against the loads in your line design.

03

Compare clamp sizes, loads and weights in a second catalogue

MacLean Power Systems publishes a standard suspension clamp table with an aluminium alloy body and keeper, hot-dip galvanised steel or ductile iron hardware and a stainless steel cotter pin. Its LS series covers cable ranges from 0.20–0.70 in (LS-0) to 1.40–2.18 in (LS-9); LS-0 is rated at 17,000 lb ultimate strength, LS-1 at 18,000 lb and LS-2 to LS-9 at 25,000 lb, while the larger ASC-12 takes 2.35–2.85 in conductors at 40,000 lb. Suffix -N means no fitting, -S a socket fitting for Class 52-3 or 52-5 insulators and -C a straight clevis for Class 52-1, 52-2, 52-4 or 52-6 insulators. [4]

The same page gives recommended U-bolt torques of 40–45 ft-lb for 1/2 in U-bolts and 65–70 ft-lb for 5/8 in U-bolts, and lists weight per 100 clamps, for example 253 lb for LS-1-N and 1,500 lb for ASC-12-S. [4]

Editorial calculation: 25,000 lb is about 111 kN and 40,000 lb about 178 kN (× 4.448 N per lbf); 40–45 ft-lb is about 54–61 N·m and 65–70 ft-lb about 88–95 N·m (× 1.356); 253 lb per 100 clamps is about 1.15 kg per clamp; a 0.40–1.05 in range is about 10.2–26.7 mm. Check that the chosen clamp's range brackets the conductor diameter plus any armour rods. [4]

Catalogue numberCable range (in)Ultimate strength (lb)Weight per 100 (lb)
LS-0-N0.20–0.7017,000180 [4]
LS-1-N0.40–1.0518,000253 [4]
LS-2-N0.40–1.0525,000273 [4]
LS-9-N1.40–2.1825,000686 [4]
ASC-12-N2.35–2.8540,0001,280 [4]

04

Trace the parts of a suspension fitting set

This is a functional reference built from the sources cited; it is not one maker's design.

PartRoleFix in the order
Clamp body and keeperGrip the conductor. [1] [2]Conductor range; material.
U-bolts, nuts and washersClamp the keeper. [1]Material; torque.
Clevis bolt or pin and cotterConnect to the string. [1] [2]Pin size; cotter material.
Yoke plate and clevis eyesForm double suspensions. [1] [3]Spacing; load.
Armour rodsProtect the conductor at the clamp. [1]Size; length.

05

Fill the specification fields with values for your line

A fitting selection needs values for your line design. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.

FieldWhat it means and published valuesAsk the supplier for
Conductor rangeE.g. 5.1–60 mm in six sizes; 0.4–0.85 in. [1] [2]Range for your conductor.
Ultimate loadE.g. 5,000–25,000 lbf vertical; 18,000 lb body. [1] [2]Rated loads; test report.
Line angleE.g. 30° single, 60° double. [1] [2]Maximum angle.
Conductor temperatureE.g. 125 °C continuous, 150 °C two-hour emergency. [1]Rating.
MaterialsE.g. aluminium alloy body; galvanised steel; ductile iron castings. [1] [3]Grades; finish.
Pin or bolt sizeE.g. 5/8 in clevis pin. [1]Interface size.
Installation torqueE.g. 480 in-lb. [2]Value.
WeightE.g. 0.4–3.1 kg per ALS clamp. [1]Value.

06

Send the conductor, load and interface data together

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Conductor: [type; size; diameter; armour rods]
Loads: [vertical; longitudinal; ultimate]
Geometry: [line angle; single or double suspension]
Temperature: [continuous; emergency]
Interface: [clevis, eye, ball or socket; pin size]
Material: [grade; galvanising]
Supply: [catalogue item or made to drawing; tests]
Volume: [quantity]

See manufacturer records Send an enquiry through CNFX

Compare power line fitting suppliers

This company lists made-to-drawing power line fittings.

Shandong Jiangkai Metal Products Co., Ltd.
Manufacturing site to be confirmed for the order

Lists made-to-drawing power line fittings and pole line hardware castings.

Product scope checked 2026-10-11

Current product source ↗

Managed by the manufacturer
Power line fittings listed

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Buyer questions

How strong is an overhead line suspension clamp?

One aluminium clamp range lists vertical ultimate loads of 5,000 to 25,000 lbf, about 22 to 111 kN by editorial calculation. [1]

What line angle can a suspension clamp take?

One maker recommends up to 30° as a single suspension and 60° in a double configuration with a yoke plate. [1]

Can power line fittings be made to drawing?

Yes; one foundry casts and machines clevises, shackles, yoke plates and clamp bodies to buyer drawings. [3]

What U-bolt torque is used on a suspension clamp?

One maker's standard suspension clamp table recommends 40–45 ft-lb for 1/2 in U-bolts and 65–70 ft-lb for 5/8 in U-bolts, about 54–61 and 88–95 N·m by editorial calculation. [4]

Sources and what still needs a direct check

Sources checked 2026-10-12. Sources are two makers' catalogue data for suspension clamps and one foundry's description of made-to-drawing fittings, cited as examples of the parameters a fitting specification covers, not endorsements.

  1. Preformed Line Products — Aluminum Suspension (ALS) Clamp, transmission catalogue section (EN-CA-1014-2) ↗ Manufacturer data Return to text ↑
  2. Hubbell (Anderson) — HAS85N suspension clamp specification sheet ↗ Manufacturer data Return to text ↑
  3. JK Casting — power line fittings and pole line hardware made to drawing, product page ↗ Manufacturer data Return to text ↑
  4. MacLean Power Systems — Suspension, Standard clamps product page and table (LS and ASC series) ↗ Manufacturer data Return to text ↑

Still to check yourself

  • Fix conductor and range.
  • Set loads and line angle.
  • Confirm temperature rating.
  • Agree material and galvanising.
  • Verify the legal supplier and factory.
Buyer enquiry

Request manufacturing insight for Electric Power Fitting

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Electric Power Fitting?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Wire Tensioning System
Last Product
Get QuotesChat