Local level indication · Magnetic or glass, float sizing and installation
A level gauge shows the level on the vessel itself. A glass gauge lets you see the liquid but can break; a magnetic level indicator keeps the liquid in a sealed chamber and moves an external indicator with a float. The float only reads right for the liquid density it was made for.
Magnetic (float) level indicators and glass, tubular and sanitary sight-glass level gauges mounted on tanks and vessels for local indication, with optional switches and transmitters. Radar, ultrasonic and hydrostatic level transmitters are covered on the level transmitter page.
01
Barksdale explains that a magnetic rotary indicator keeps the visual indicator and switches isolated from the liquid, with the tank sealed from the surroundings, so spills from sight-glass breakage are eliminated. Its float housing is a pressure vessel mounted on the tank and built for the tank's pressure and temperature, in stainless steel or in PVC, PP or PVDF for corrosive service. [2]
ABB describes its LMG100 magnetic level gauge as a float, a chamber connected to the vessel and an indicator of shuttle or flags in a sealed tube beside it, coupled magnetically to the float. [1] Glass and tubular gauges instead show the liquid itself.
Give the supplier the liquid and its specific gravity range, operating and design pressure and temperature, connection centre-to-centre distance and flange rating, and whether switches or a transmitter are needed.
02
ABB's manual explains that the float is designed and weighted for the process liquid, sitting about 70–80% submerged, and that magnets and indicator are aligned so the indication matches the level at the reference specific gravity. If specific gravity falls, the float sinks deeper and the gauge reads lower than the true level; if it changes significantly in service, the float should be checked. [1]
Barksdale lists its LevelSite indicator for liquids down to a specific gravity of about 0.50, pressures to 310 bar and temperatures to 316 °C, which shows how much float and chamber design depend on the service. Give the supplier the lowest specific gravity the liquid will reach. [2]
03
ABB states the chamber must be vertically level, or the float may rub the walls or move too far from the indicator and decouple. Barksdale warns that misaligned tank flanges distort the float chamber so the float may stick, that the indicator must be mounted vertically, and that the flags should be reset with a magnet before commissioning. [1] [2]
Ask for the connection centre distance tolerance, vent and drain arrangements, and whether the float is shipped inside the chamber or separately (ABB notes floats are labelled with top, specific gravity and chamber serial number). [1]
04
ABB explains that magnetically actuated limit switches can be clamped to the chamber and adjusted over the whole range, actuated by the float's magnet, and that a magnetostrictive transmitter can be added to an existing gauge for a remote signal. [1]
If you need a continuous 4–20 mA signal, decide whether to add a transmitter to the gauge or install a separate level transmitter.
05
BCST lists customisable magnetic level gauges; Aister lists magnetic level gauges with flow meters; Dongrun lists magnetic float level gauges among level instruments; Aether lists level gauges among level sensors; Donjoy lists level gauges for tank equipment. [3] [4]
06
Tie the float row to your liquid: ABB designs and weights its float for the process liquid at about 70–80% submerged, so the order needs the specific-gravity range. [1]
| Part | Role | Fix in the order |
|---|---|---|
| Chamber | Pressure-containing tube on the vessel. [2] [1] | Material, rating, centre distance. |
| Float | Magnetic float sized to specific gravity. [1] | SG range, material, pressure rating. |
| Indicator | Flags or shuttle, isolated from liquid. [2] [1] | Type, scale, visibility. |
| Glass and frame (glass gauges) | Shows liquid directly. | Glass type, guard, rating. |
| Connections, vent and drain | Join to vessel; allow service. [2] | Flange size, rating, valves. |
| Switches and transmitter | Remote alarms or signal. [1] | Switch type, transmitter output. |
07
Accuracy follows from how well the float matches the liquid's specific gravity, so ask for it at the lowest and highest SG in service; measuring range, protection class, supply voltage and weight have no published value here. [1]
| Field | What it means and published values | Ask the supplier for |
|---|---|---|
| Measuring range (mm) | Centre-to-centre of connections. | Range and visible length. |
| Accuracy (mm) | Depends on float sizing to SG. [1] | Accuracy at your SG range. |
| Operating temperature (°C) | Chamber and indicator limits. [2] | Limits for chamber and indicator. |
| Operating pressure (MPa) | Chamber designed for tank pressure. [2] | Design pressure and test. |
| Process connection | Flange size and rating; alignment matters. [2] | Connection details. |
| Material | Stainless steel or plastics for corrosive service. [2] | Wetted materials. |
| Protection class | Indicator and switch enclosure. | IP rating. |
| Output signal (mA) | Via add-on transmitter. [1] | Transmitter type and output. |
| Supply voltage (V DC) | For switches or transmitter. | Voltage. |
| Weight (kg) | Support on the vessel. | Mass. |
08
Paste it into your enquiry below or into an email to a maker, then replace every bracket.
Liquid: [name; specific gravity range; temperature; corrosive or not; interface if any] Vessel: [design pressure and temperature; connection centre distance; flange size and rating] Gauge: [magnetic indicator or glass; indicator type; scale] Options: [limit switches; transmitter and output; vent and drain valves] Installation: [indoor or outdoor; insulation or heating] Documents: [drawing; float SG label; pressure test certificate]
11 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Lists customisable magnetic level gauges.
Product scope checked 2026-10-11
Lists magnetic level gauges alongside flow meters.
Product scope checked 2026-10-11
Lists magnetic float level gauges among level instruments and water analyzers.
Product scope checked 2026-10-11
Lists level gauges among level sensors and switches.
Product scope checked 2026-10-11
Lists level gauges for tank equipment.
Product scope checked 2026-10-11
Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.
If the liquid's specific gravity is lower than the float was designed for, the float sinks deeper and the gauge reads low. [1]
A magnetic gauge keeps the liquid in a sealed chamber and avoids spills from glass breakage; a glass gauge shows the liquid directly. [2]
Yes; magnetically actuated limit switches clamp to the chamber, and a magnetostrictive transmitter can be added for a remote signal. [1]
Sources checked 2026-10-11. ABB's LMG100 manual and Barksdale's LevelSite guide are manufacturers' documents explaining magnetic level indicators. Supplier pages describe their own offers.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.