This page explains how Detection IC (Integrated Circuit) is classified within Computer, Electronic and Optical Product Manufacturing. Technical values and manufacturer relationships are research references; confirm the current specification and supplier evidence for each order.
A specialized integrated circuit that monitors electrical parameters and detects ground fault conditions in GFCI systems.
Technical details and manufacturing context for Detection IC (Integrated Circuit)
| Parameter | Typical range | Notes & selection driver |
|---|---|---|
| Supply Voltage | 3.3–5.5 V | Operating range for logic and analog circuits |
| Quiescent Current | 0.5–2 mA | Low power consumption for battery-operated devices |
| Detection Threshold | 4–6 mA | Ground fault trip current per UL 943UL 943 |
| Response Time | 20–40 ms | Time to trip after fault detectionUL 943 |
| Operating Temperature | -40–85 °C | Junction temperature rangeIEC 60747 |
| Storage Temperature | -55–150 °C | Non-operating storage rangeIEC 60747 |
| Input Offset Voltage | ±0.5 mV | Affects detection accuracy |
| Input Bias Current | 1–10 nA | Low bias current for high impedance sensing |
| Output Drive Capability | 10–50 mA | Capable of driving SCR or relay |
| Package Type | SOIC-8 | Standard surface-mount packageJEDEC MS-012 |
| ESD Rating | ±2000 V | Human body modelIEC 61000-4-2 |
| Moisture Sensitivity Level | 1 | Floor life unlimitedIPC/JEDEC J-STD-020 |
Ranges are indicative industry figures for RFQ preparation, not a supplier commitment. Confirm every value and standard with the legal manufacturer before ordering.
Commonly used trade names and technical identifiers for Detection IC (Integrated Circuit).
This component is essential for the following industrial systems and equipment:
| current: | Up to 30mA differential current detection |
| voltage: | Up to 277V AC |
| frequency: | 50/60Hz line frequency compatibility |
| temperature: | -40°C to +125°C |
Indicative industry ranges for design and RFQ preparation. Confirm the exact figures and applicable standard with the manufacturer before specifying.
Quoted from the published standard.
11 companies list this product among what they make. Company figures are quoted from each company's own website; every card states where the relationship came from.
Manufacturer listings support early research and capability understanding. They are not certification, ranking, or transaction guarantees.
A practical evidence checklist for RFQ preparation and supplier evaluation.
CNFX does not score or rank suppliers. Buyers must verify all claims and documents with the legal manufacturer before ordering.
The Detection IC monitors the current differential between hot and neutral conductors in a GFCI system. When an imbalance indicates a ground fault, it triggers a response to interrupt power, preventing electrical shock.
The detection threshold is typically 4-6 mA, and the response time is 20-40 ms, as referenced in UL 943. These values are directory references and must be confirmed for the specific model.
The Detection IC is available in a standard SOIC-8 surface-mount package, per JEDEC MS-012. This is a common package for such components.
Relevant standards include UL 943 for ground fault protection, IEC 60747 for semiconductor devices, IEC 61000-4-2 for ESD, and IPC/JEDEC J-STD-020 for moisture sensitivity. Always verify compliance with the manufacturer.
Editorial classification, named public sources where available, and source-reviewed manufacturer records.
Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.
Compare manufacturer profiles with relevant product and process capability.