Cable management duct (wiring duct)

Wiring duct for panels and enclosures · Slot style and size, PVC versus halogen-free material, continuous-use temperature, UL 94 flammability, mounting and covers

A cable management duct (wiring duct) is a rigid plastic channel with slotted or solid side walls and a snap-on cover, fixed inside control panels, racks and battery enclosures, that routes, separates and protects wires between components while letting them leave the duct at any slot. Ask three things first: the width, height and slot style needed for your wire bundles, the material and its continuous-use temperature in the enclosure, and the flammability rating and mounting method required.

Slotted and solid-wall plastic wiring duct with covers for control panels, telecom racks and battery enclosures. Building cable trays and ladders, conduits, surface raceway for walls and cable tray roll-forming machines are outside this page.

CNFX editorial research · Sources checked October 12, 2026 · 4 sources

01

Size the duct and choose the slot style

Panduit's Panduct catalogue page lists wiring duct styles including wide-finger flush (Type G), narrow-finger flush (F), solid-wall flush (FS), wide-finger hinged (H), round-hole flush (D), halogen-free, NORYL wide-finger (NE) and low-smoke metric designs, with base and cover sold separately in 6 ft lengths. Type G black duct runs from 23.6 × 51.6 mm (0.93 × 2.03 in) to 108.0 × 129.5 mm (4.25 × 5.10 in) overall. [1]

The G2X2WH6-A data sheet describes a nominal 2.0 × 2.0 in (50.8 × 50.8 mm) wide-slot duct, 57.2 mm wide and 53.8 mm high overall, 1.8 m long, with 7.9 mm slots; its wide finger and slot design gives greater sidewall rigidity, and score lines allow fingers and sidewall sections to be removed. [2]

Editorial calculation: a 10 m duct run in 1.8 m (6 ft) lengths needs 10 ÷ 1.83 ≈ 5.5, so six base lengths and six covers, before allowing for offcuts at corners and tees. [2]

A second maker's table adds wall thickness, slot geometry and wire capacity. Changhong Plastics (CHS) lists its grey PVC slotted duct (PXC series) from 20 × 15 mm to 130 × 100 mm (height × width), with 1.5 mm wall thickness on the smaller sizes, 1.8 mm on sizes such as 50 × 55, 50 × 60, 60 × 60 and 65 × 65 mm, and 2.1 mm on 50 × 100, 60 × 100 and the 100 mm and 130 mm heights. Slot width (A) runs 4, 6, 8 or 10 mm with slot pitch (B) of 6, 8, 9, 10 or 12 mm, and the table states a contained-wire capacity in 1.5 mm² wires: 5–10 for 20 × 15 mm, 45–55 for 40 × 40 mm, 90–100 for 50 × 50 mm and 220–250 for 50 × 100 mm and 350–500 for 130 × 100 mm. [3]

Editorial calculation: doubling the CHS duct from 50 × 50 mm to 50 × 100 mm raises the stated 1.5 mm² wire capacity from 90–100 to 220–250, about 2.4 to 2.5 times; ask each supplier for its own fill table at the wire size you use rather than scaling by area. [3]

Give the supplier the duct width and height, slot style (wide or narrow finger, solid wall, round hole), length, colour, material (PVC, halogen-free, low-smoke), required continuous-use temperature, flammability rating, mounting (holes, adhesive, DIN rail), cover type, certifications and quantities.

02

Check material, temperature rating, flammability and mounting

Panduit's Type G duct is made of rigid PVC (lead-free in the G2X2WH6-A), rated UL 94 V-0, with a UL-recognised continuous-use temperature of 50 °C (122 °F); Panduit states it conforms with NFPA 79-2002 section 14.3.1 for flame-retardant material. The same catalogue offers halogen-free and NORYL duct styles as separate types. [1] [2]

The data sheet notes that adhesive tape is not meant for permanent mounting of wiring duct; a mounting hole at each end is exposed for permanent fixing with fasteners, and surfaces should be clean, dry and grease-free. The duct is listed as RoHS compliant, UL recognised and CE compliant. [2]

Editorial note: battery enclosures and panels with heat-producing devices can exceed 50 °C locally; ask the supplier for the continuous-use temperature of the specific material and for any halogen-free or low-smoke requirement your project specifies.

Ratings differ by maker and test basis: CHS describes its grey PVC duct as heat-resisting up to 85 °C, while Panduit's Type G PVC carries a UL-recognised continuous-use temperature of 50 °C. Ask which test or listing a quoted temperature comes from before comparing them. [3] [1]

03

Ask whether the duct is tested as a cable trunking system

IEC 61084-1:2017 "specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS)" that hold, and where necessary give electrically protective separation for, insulated conductors, cables and other equipment in electrical or communication installations with a maximum voltage of 1 000 V AC and 1 500 V DC. It excludes conduit, cable tray, cable ladder and power track systems. The second edition, published on 22 March 2017, replaced the 1991 first edition and its 1993 amendment, with changes to classification, construction, and mechanical and electrical properties; a European adoption is listed as FprEN IEC 61084-1:2024. [4]

The ratings this page already lists are North American: Panduit's Type G duct is rigid PVC rated UL 94 V-0 with a UL continuous-use temperature of 50 °C, and Panduit cites NFPA 79 for flame-retardant material [1] [2]. For panels built to IEC rules, ask whether the duct and cover are tested as a system to IEC 61084-1 with its relevant Part 2, which classification applies, and whether it is used for the protective separation of circuits, which the standard addresses.

Changhong (CHS) lists wall thicknesses of 1.5, 1.8 and 2.1 mm by size and a heat-resisting grade "up to 85 °C" [3]. Ask each supplier for the test standard behind any temperature and flammability claim, since a UL file and an IEC 61084 classification are separate assessments.

Editorial calculation: the 2017 edition replaced one published 26 years earlier (1991); the 1 000 V AC limit is four times a 250 V control circuit. [4]

ItemIEC 61084-1:2017 (Standard Norge catalogue)
CoversCable trunking systems (CTS) and cable ducting systems (CDS)
Voltage limit of installations1 000 V AC and 1 500 V DC
ExcludedConduit systems, cable tray, cable ladder, power track systems
Changes from edition 1Classification; construction; mechanical and electrical properties
UsePart 1 is "not intended to be used by itself" (read with the relevant Part 2)
Edition and dateEdition 2, 22 March 2017; replaced 1991 edition and Amendment 1:1993

Values are from the Standard Norge catalogue page for IEC 61084-1:2017; the Part 2 documents and classification tables were not reviewed.

04

Compare what suppliers offer

Suppliers linked to this page list plastic wiring duct; each card links to the page reviewed.

Listings include slotted and solid wiring duct, round wiring duct and cable raceway among cable ties and glands.

05

Trace the duct components

This is a functional reference built from the sources cited; it is not one maker's design.

PartRoleFix in the order
BaseHolds and routes wires. [2]Size and slot style.
Fingers and slotsLet wires exit; 4–10 mm slots at 6–12 mm pitch in one range. [2] [3]Slot width and pitch.
CoverCloses the duct. [1]Flush or hinged.
MaterialSets temperature and fire rating. [1]PVC or halogen-free.
MountingFixes to panel. [2]Holes, fasteners, adhesive.
AccessoriesCorners, ends, dividers.Parts needed.

06

Fill the specification fields with values for your enclosure

A wiring duct quotation needs values for your enclosure. The table explains each field, gives published values where a reviewed source states them, and says what to obtain from the supplier.

FieldWhat it means and published valuesAsk the supplier for
Cross-section (W×H) (mm)23.6 × 51.6 to 108.0 × 129.5 mm in one range. [1]Overall and inside sizes.
Length (mm)1.8 m (6 ft) in one range. [2]Length.
Wall Thickness (mm)1.5 mm, 1.8 mm or 2.1 mm by size in one range. [3]Value.
MaterialRigid PVC, lead-free in one part. [2]Material grade.
Flammability RatingUL 94 V-0 in one range. [1]Rating and file.
Operating Temperature (°C)50 °C UL continuous use (one range); "up to 85 °C" heat-resisting (another). [1] [3]Continuous-use rating.
IP RatingOpen slots give no ingress protection.Not applicable or value.
Tensile Strength (MPa)Material.Value.
Impact Strength (Izod) (kJ/m²)Material.Value.
Dielectric Strength (kV/mm)Material.Value.
Weight per Meter (kg/m)Handling.Weight.
Test standardUL 94 / NFPA 79 claims in one range [1]; IEC 61084-1 for cable trunking systems up to 1 000 V AC. [4]Standard, classification, certificate.

07

Send the size, material and fire data together

Paste it into your enquiry below or into an email to a maker, then replace every bracket.

Size: [width; height; length]
Style: [slot type; cover type]
Material: [PVC; halogen-free; low-smoke]
Ratings: [continuous-use temperature; UL 94]
Mounting: [holes; adhesive; fasteners]
Supply: [colour; accessories; quantity]

See manufacturer records Send an enquiry through CNFX

Compare wiring duct suppliers

These companies list plastic wiring duct.

Changhong Plastics Group Imperial Plastics Co., Ltd.
Manufacturing site to be confirmed for the order

Lists slotted and solid wiring duct, round wiring duct and cable raceway among cable ties and glands.

Product scope checked 2026-10-11

Current product source ↗

Wiring duct listed · profile compiled by CNFX from public sources
Anhui Honor Electric Co., Ltd.
Anhui, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray”
View source page ↗ honorelectric.cn · recorded 2026-10-11
Lingyufab
Shanghai, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Metal Cable Tray”
View source page ↗ lingyufab.com · recorded 2026-10-15
Ningbo Vichnet Technology Co.,Ltd
Ningbo, Zhejiang, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Wire Mesh Cable Tray”
View source page ↗ vichnet.com · recorded 2026-08-30
PowerTel Solutions Limited
Jiangsu, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray & Raceway”
View source page ↗ powertel-solutions.com · recorded 2026-08-31
Shandong TIANLU Heavy Industry Technology Co., Ltd.
Shandong, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray”
View source page ↗ tianlulift.com · recorded 2026-09-16
Taian BOWINS Garment
Shandong, CN
Also makes: Safety Features
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray”
View source page ↗ bowinsgarment.com · recorded 2026-09-08
TAIZHOU RUIQI TOOLS CO., LTD.
Zhejiang, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray Sheaves”
View source page ↗ tlpchina.com · recorded 2026-09-05
Wenzhou Kinee Electrical Co., Ltd.
Wenzhou, Zhejiang, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray Clamp”
View source page ↗ kinee.net · recorded 2026-09-09
WENZHOU MINGZHE ELECTRIC CO LTD
Yueqing, Zhejiang, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “Cable Tray”
View source page ↗ mingzhee.com · recorded 2026-09-03
Zaoqiang Xinpeng Fiberglass Co., Ltd.
Hebei, CN
Listed on the company's own website · profile compiled by CNFX from public sources
Listed there as: “FRP Cable Trays”
View source page ↗ xpfrp.com · recorded 2026-09-17
View All Factories

Explore company information and manufacturing capabilities, then discuss the scope of your project with a relevant supplier.

Share this page

Buyer questions

What temperature can PVC wiring duct take?

Panduit's PVC Type G duct is UL-recognised for continuous use up to 50 °C (122 °F). [1]

Can wiring duct be mounted with its adhesive tape alone?

Panduit states adhesive tape is not meant for permanent mounting; use the mounting holes and fasteners. [2]

What flammability rating does wiring duct carry?

Panduit's Type G duct is UL 94 V-0 and conforms to NFPA 79-2002 section 14.3.1 for flame-retardant material. [1]

How many wires fit in a wiring duct?

It depends on size and wire; CHS states 90–100 wires of 1.5 mm² for its 50 × 50 mm slotted duct and 220–250 for 50 × 100 mm. [3]

Which IEC standard covers plastic wiring duct and trunking?

IEC 61084-1:2017 specifies requirements and tests for cable trunking and ducting systems in installations up to 1 000 V AC and 1 500 V DC; it is used together with the relevant Part 2 and excludes conduit, cable tray and ladder systems. [4]

Sources and what still needs a direct check

Sources checked 2026-10-12. Panduit publishes catalogue and data-sheet values for its own wiring duct, and Changhong Plastics (CHS) publishes a size, wall-thickness, slot and wire-capacity table for its slotted duct; ratings for your duct must come from the supplier.

  1. Panduit — PANDUCT wiring duct catalogue pages (PDF via Farnell) ↗ Maker catalogue Return to text ↑
  2. Panduit — Panduct G2X2WH6-A base wiring duct data sheet (PDF) ↗ Maker data sheet Return to text ↑
  3. Changhong Plastics (CHS) — Wiring duct (slotted) technical parameters ↗ Maker technical page Return to text ↑
  4. IEC — IEC 61084-1:2017 ED2, Cable trunking and ducting systems for electrical installations — Part 1: General requirements (Standard Norge catalogue) ↗ Standard abstract Return to text ↑

Still to check yourself

  • Size duct for bundles and spare space.
  • Choose slot style.
  • Confirm material temperature rating.
  • Check flammability and halogen-free needs.
  • Verify the legal supplier and factory.
Buyer enquiry

Request manufacturing insight for Cable Management Duct

Ask for use case, specification boundaries, supplier type, and RFQ preparation information for this product.

Where it goes
Straight to the CNFX editorial desk, and to the manufacturer if this product is linked to a claimed profile. Nothing is broadcast to a supplier list.
Your details stay here
We do not sell or rent enquiry data, and we do not add you to a mailing list. Used only to answer this request.
No commission, no middleman
CNFX is a directory. We take no cut of any order and never negotiate on a supplier's behalf.
What to include
Share your product specifications, quantity, destination and target delivery date.

Your business information is used only to process this request.

Thank you! Your message has been sent. We'll respond within 1–3 business days.
Sorry, we couldn't send your message. Please try again, or email us at [email protected].

Need to Manufacture Cable Management Duct?

Compare manufacturer profiles with relevant product and process capability.

Previous Product
Wire Tensioning System
Last Product
Get QuotesChat